Pacific PLA-E30AS Скачать руководство пользователя страница 4

Important Safety Notice

3

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

CAUTION

To reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings,
attics, crawl spaces or garages.

Not for use over an outdoor g

r

ill.

OPERATION

Always leave safety grilles and fi lters in place. Without these components, operating blowers could catch onto hair, fi ngers 
and loose clothing.

The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, 
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to 
negligence and the warranty of the unit automatically expires due to improper maintenance.

ELECTRICAL REQUIREMENTS

Important:

Observe all governing codes and ordinances.

It is the customer’s responsibility:
-  To contact a qualifi ed electrical installer.
-  To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 

latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and 
all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualifi ed electrician determine that the 
ground path is adequate.

Do not ground to a gas pipe.

Check with a qualifi ed electrician if you are not sure the range hood is properly grounded.

Do not have a fuse in the neutral or ground circuit.

*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575

This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit 
protected by a 15 or 20 ampere circuit breaker or time delay fuse.  Wiring must be 2 wire with ground.  Please also refer to 
Electrical Diagram on product.

A cable locking connector (not supplied) might also be required by local codes.  Check with local requirements, purchase 
and install appropriate connector if necessary.

Содержание PLA-E30AS

Страница 1: ...Use Care and Installation Guide Model PLA E30AS PLA E36AS XP022419 1...

Страница 2: ...ist of Materials Ducting Calculation Sheet 5 Mounting Height Clearance 6 Ducting Options 7 Hood Specifcations 8 9 Control Mounting the Hood 10 Light Bulbs 12 Troubleshooting 13 Hood and Filter Cleanin...

Страница 3: ...of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or me...

Страница 4: ...trical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition...

Страница 5: ...ocal codes Extension duct cover accessory Recirculating kit accessory HARDWARE PACKAGE CONTENTS 1 Suction Cup PARTS SUPPLIED MODELS 3LA E30AS 3LA E36AS 1 Hood with internal blower 1 Duct cover wall br...

Страница 6: ...ent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round ro...

Страница 7: ...performance and efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differe...

Страница 8: ...e unless using the recirculating option Use single wall rigid metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting O...

Страница 9: ...on Hood Specifi cation 6 CL 29 15 16 35 7 16 14 1 8 2 13 16 20 1 16 STANDARD min ducted 26 min recirc 31 max 49 EXTENSION min ducted 41 min recirc 46 max 78 11 7 1 16 9 7 16 10 9 16 2 3 16 3 9 16 5 TO...

Страница 10: ...inside of hood into wall for extra support FIG A 2 9 Center and attach duct cover mounting bracket to wall just below the ceiling or soffit using 2 M6 x 1 screws FIG A 3 10 Install duct work and seal...

Страница 11: ...Blower Speed Selection 2 Delay Off Timer 4 Blower On Off Press to turn blower on and off If lights are on they will also switch off when this button is pressed Press to cycle through light levels Brig...

Страница 12: ...ean cotton cloth and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Aluminum Mesh Filters The aluminum mesh lters installed by the factory are intended to...

Страница 13: ...y turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach the included glass suction cup or...

Страница 14: ...e defective part The unit is vibrating 1 The motor is not secured in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the insta...

Отзывы: