Pacific PLA-E30AS Скачать руководство пользователя страница 14

1

Troubleshooting

TROUBLESHOOTING PROCEDURES FOR VLA

Issue

Cause

What to do

After installation, 
the unit doesn’t 
work.

1.  The power source is not turned ON.

1.  Make sure the circuit breaker and the unit’s 

power is ON.

2.  The power line and the cable locking connector 

is not connecting properly.

2.  Check the power connection with the unit is 

connected properly.

3.  The switch board and control board wirings are 

disconnected.

3.  Make sure the wirings between the switch 

board and control board are connected 
properly.

4.  The switch board or control board is defective.

4.  Change the switch board or control board.

Light works, 
but motor is not 
turning.

1.  The motor is defective, possibly seized.

1.  Change the motor.

2.  The thermally protected system detects if the 

motor is too hot to operate and shuts the motor 
down.

2.  The motor will function properly after the 

thermally protected system cool down.

3.  Damaged capacitor.

3.  Change the capacitor.

4.  The switch board or control board is defective.

4.  Change defective part.

The unit is 
vibrating.

1.  The motor is not secured in place.

1.  Tighten the motor in place.

2.  Damaged blower wheel.

2.  Replace the blower.

3.  The hood is not secured in place.

3.  Check the installation of the hood.

4.  The switch board or control board is defective.

4.  Change defective part.

The motor is 
working, but the 
lights are not.

1.  Defective halogen bulb.

1.  Change the halogen bulb.

2.  The light bulb is loose.

2.  Tighten the light bulb.

The hood is 
not venting out 
properly.

1.  The hood might be hanging to high from the 

cook top.

1.  Adjust the distance between the cook top and 

the bottom of the hood within 26” and 34” 
range.

2.  The wind from the opened windows or opened 

doors in the surrounding area are affecting the 
ventilation of the hood.

2.  Close all the windows and doors to eliminate 

the outside wind fl ow.

3.  Blockage in the duct opening or ductwork.

3.  Remove all the blocking from the duct work or 

duct opening.

4.  The direction of duct opening is against the wind.

4.  Adjust the duct opening direction.

5.  Using the wrong size of ducting.

5.  Change the ducting to at least 6” or higher for 

the internal blower.

Mesh Filter is 
vibrating.

1.  Mesh fi lter is loose.

1.  Change the mesh fi lter.

Содержание PLA-E30AS

Страница 1: ...Use Care and Installation Guide Model PLA E30AS PLA E36AS XP022419 1...

Страница 2: ...ist of Materials Ducting Calculation Sheet 5 Mounting Height Clearance 6 Ducting Options 7 Hood Specifcations 8 9 Control Mounting the Hood 10 Light Bulbs 12 Troubleshooting 13 Hood and Filter Cleanin...

Страница 3: ...of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or me...

Страница 4: ...trical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition...

Страница 5: ...ocal codes Extension duct cover accessory Recirculating kit accessory HARDWARE PACKAGE CONTENTS 1 Suction Cup PARTS SUPPLIED MODELS 3LA E30AS 3LA E36AS 1 Hood with internal blower 1 Duct cover wall br...

Страница 6: ...ent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round ro...

Страница 7: ...performance and efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differe...

Страница 8: ...e unless using the recirculating option Use single wall rigid metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting O...

Страница 9: ...on Hood Specifi cation 6 CL 29 15 16 35 7 16 14 1 8 2 13 16 20 1 16 STANDARD min ducted 26 min recirc 31 max 49 EXTENSION min ducted 41 min recirc 46 max 78 11 7 1 16 9 7 16 10 9 16 2 3 16 3 9 16 5 TO...

Страница 10: ...inside of hood into wall for extra support FIG A 2 9 Center and attach duct cover mounting bracket to wall just below the ceiling or soffit using 2 M6 x 1 screws FIG A 3 10 Install duct work and seal...

Страница 11: ...Blower Speed Selection 2 Delay Off Timer 4 Blower On Off Press to turn blower on and off If lights are on they will also switch off when this button is pressed Press to cycle through light levels Brig...

Страница 12: ...ean cotton cloth and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Aluminum Mesh Filters The aluminum mesh lters installed by the factory are intended to...

Страница 13: ...y turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach the included glass suction cup or...

Страница 14: ...e defective part The unit is vibrating 1 The motor is not secured in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the insta...

Отзывы: