Pacific Ventilation
9
Mounting sequence
1.
Use the template to mark the
mounting location for the fan and
make a hole in the ceiling Ø 300 mm.
2.
The flexible air duct is pushed
through the hole from behind the
ceiling, from above. The air duct is
installed on a spigot with a non-
return valve.
3.
Before installation, it is required to
loosen the self-tapping screws on
the rocking levers, thereby increasing
the gap between the casing and the
lever.
Ø
300
Ø
300
Ø
300
4.
The spigot and the air duct are
installed on the fan.
5.
The fan assembly is inserted into the
ceiling opening from the room side.
6.
Secure the fan by turning the levers.
Ø
300
Ø
300
Ø
300
7.
After installing the fan, it is necessary
to clamp the self-tapping screws on
the rocking levers to press the fan
casing against the ceiling.
8.
Install the decorative panel (purchased separately for the BEC 150HP model)
on the fan casing. The panel is mounted in accordance with the User’s manual
for the decorative panel.