AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 301 of 485
8.7.11
STEP Transient Commands
The command in this section control STEP transients. Some of these commands have the
option to specify NORmal or SATurate.
SATurate mode:
If a dwell time setting is out of limits, the dwell time will saturate to the
limit min/max and it will not trip an error.
NORmal mode
:
If a dwell time setting is out of limits, an error will be generated and
the dwell time setting will not be modified.
Command Syntax
[SOURce:]STEP:MODE < INIDEL | 0 | FINDEL | 1 | INIFIN | 2 >
Description
This command sets the programming mode for a STEP Transient.
0 | INIDEL
Allows programming the step by initial and delta values
1 | FINDEL Allows programming the step by final and delta values
2 | INIFIN Allows programming the step by initial and final values
Parameters
< INIDEL | 0 | FINDEL | 1 | INIFIN | 2>
Parameter Format
<cr> or <nr1>
Example
STEP:MODE 1
Query Format
[SOURce:]STEP:MODE?
Returned Data Format
<nr1>
Query Example
STEP:MODE?
1
Query Syntax
[SOURce:]STEP:MODE:CATalog?
Description
This command returns the available mode settings for a STEP
Transient.
0 | INIDEL
Allows programming the step by initial and delta values
1 | FINDEL Allows programming the step by final and delta values
2 | INIFIN Allows programming the step by initial and final values
Returned Data Format
<nr1>
Query Example
STEP:MODE:CAT?
0,Initial and delta,1,Final and delta,2,Initial and final
Command Syntax
[SOURce:]STEP:INITialvalue <OFF|0|ON|1>
Description
This command determines if an initial value step is inserted at the
beginning of each repeat of a step transient.
0 | ON
Allows programming the step by initial and delta values
1 | OFF
Allows programming the step by final and delta values
Parameters
< OFF | 0 | ON | 1 >
Parameter Format
<cr> or <nr1>
Example
STEP:INIT ON
Query Format
[SOURce:]STEP:INITialvalue?
Returned Data Format
<b>
Query Example
STEP:INIT?
1