Pacific Image Electronics Slite 600 Скачать руководство пользователя страница 2

For over 15 years,  Pacific Image Electronics Co., Ltd. has been continuously devoting tremendous 
RD energy toward various fields such as electronic engineering, imaging analysis, and optics 
application  to develop and manufacture the most innovative electronic products  that exactly 
fulfill customers’  needs.    Based on accumulated  professional  experiences for  more than a 
decade on developing the latest electronic products PIE has successfully crossed the gaps in 
between electronics and biomedicine and farther marches forward to biomedical field with a 
series of innovative lab instrument and reagent products that help researchers to approach their 
goals in high level of biomedicine research.    Further with foresightingly conceptual 
combinations of product categories on lab required instruments and experimental reagents, PIE  
has been accomplishing  tasks on integration of instruments  and  reagents  to  provide  quality  
and  innovative  lab  automatic  instruments  for 
researchers to conduct research projects with high efficiency and high accuracy. 
 
 
 

SAFETY INFORMATION 

 
 
NOTE: All PIE UV Transilluminators are powerful sources of Ultraviolet (UV) radiation that can 
cause damage to unprotected eyes and skin. Be sure all personnel in the area are properly 
trained and protected before operating any unit that uses UV radiation. 
 
 
 
It is further recommended that the transilluminator be installed and operated in a darkroom 
where access and exposure is limited while the unit is in operation. For your safety and for the 
safety of those around you, the transilluminator in an PIE darkroom is controlled through the 
darkroom, and each darkroom is equipped with a safety switch that controls the power to the 
transilluminator to prevent accidental exposure. 

 
 
 
 
 

For Research Only

 

 

  

Pacific Image Electronics Co., Ltd. Web: www.scanace.com 

TEL/+886286921800  FAX+886286921860 

7F, No. 239, Sec. 1 Datong Rd., Xizhi Dist., New Taipei City 221, Taiwan   

Содержание Slite 600

Страница 1: ...Slite 600 600C Gel Documentation SYSTEM USER S MANUAL ...

Страница 2: ...s on integration of instruments and reagents to provide quality and innovative lab automatic instruments for researchers to conduct research projects with high efficiency and high accuracy SAFETY INFORMATION NOTE All PIE UV Transilluminators are powerful sources of Ultraviolet UV radiation that can cause damage to unprotectedeyes and skin Be sure all personnel in the area are properly trained and pr...

Страница 3: ... The Initial Configuration Settings Before Use 6 Slite 600 Quick Guide for Agarose EtBr Gel 7 Setting Manager 9 Slite 600 Operation Manual 10 Illuminator Setting and Operation 13 WIFI Setting and Control 16 Troubleshooting 17 Hardware Specifications 18 Warranty 19 Technical Supports 19 ...

Страница 4: ...Followed the design concept of a single independentworkstation on bench top Slite 600 does not require any desktops to work with A built in touch screen LCD panel Slite 600 can directly handle the image data process without any difficulty Moreover smart user friendly interfaces and vivid icons Slite 600 has rapidly capture gel images with an easy manner With having Slite 600 in the laboratory you ...

Страница 5: ...ie silver stained gels and colony plates It also applies for the illumination of samples with transilluminating white light UV Transilluminator UV transilluminator allows the excitation of multiple fluorescent dyes to occur To protect users from UV exposure UV light is automatically shut off when door is open UV transilluminator can be slided in out of cabinet smoothly LCD Touch Screen A built in 8...

Страница 6: ...uminator and be well accommodated with Slite 600 Optional Accessories and Parts Please contact your local PIE dealer for more information of the optional accessories and parts Filters 535nm 35 For gels or plates stained with SYBR Green SYBR Safe SYBR Gold Fluorescein Green Fluorescent Protein stains Thermal Printer The USB connected compact digital thermal printer may print out archive quality pri...

Страница 7: ... desired image data The parameters such as Network Image Size Bit Depth Save Format Date Time and many other settings can be reset more directly on screen Image Capture Mode Settings USB Flash Drive FAT FAT32 NTFS Please note the USB flash drive pre formatted in the most popular FAT FAT32 or NTFS type file system is applied to Slite 600 All three USB ports on system are available for USB Flash Dri...

Страница 8: ...eIMAGE CAPTURE MENU page as on Page 7 Open the chamber door The automatic turn on of Epi white light while door is open makes users easy toplace the sample into the cabinet Slide out the UV transilluminator and place the staining gel onto UV transilluminator or light board Slide the transilluminator back to the original position in chamber Press to enter SETTING MENU as on Page 7 Select for basic ...

Страница 9: ...age Slite 600 screen will get into IMAGE PERUSE MENU Press to convert the color into its complementary color Press to print image Digital thermal printer must be connected Press to save image to USB flash drive Press to delete the on screen image press to clear all images Press to back to IMAGE CAPTURE MENU IMAGE CAPTURE MENU SETTING MENU IMAGE PERUSE MENU 8 1 ...

Страница 10: ... Software Version Firmware Version etc Press to resume all settings back to factory default value Others Info Print Press to display the image info on the printout data Sleep Press to activate the hibernating mode Press screen to wake up hibernating system Sat Press to activate saturation display function Date and Time Press to set Date time When settings are all finished press your settings are s...

Страница 11: ... again to turn off the light source Press to turn on 312nm UV light Press to turn on Epi white light in the chamber Press to turn on white backlight When white backlight board is installed the white backlight board light source selection icon will automatically display on screen Press to turn on cyan light When cyan light board is installed the lighting source selection icon will be available disp...

Страница 12: ...e Press to capture image Exposure Time Setting Press arrows on screen to select the desired exposure time the range is from 0 001 seconds 10 seconds Captured Image Preview Captured image will be temporarily stored in the system Press the image to display the captured image in IMAGE PERUSE MENU Users may further process the captured image by using the functional icons in the menu Press arrows to se...

Страница 13: ...U Users may further edit the captured image by using the functional icons in the menu Press arrows to select the desired captured image Change the file name of the captured image Press a keyboard will show on the screen Users may delete the filename by pressing the backspace key on the keyboard and rename the file by typing the desired letters Once the filename is retyped press OK to complete the ...

Страница 14: ...board can be activated and the image data stained By colorimetric dye can be selected adjusted saved and printed with convenience Cyan Red Epi illuminator Cyan Red Epi illuminator module is designed for observing the Cyan light excited fluorescent dye stained gel data The gel image data may also be obtained through Slite 600 Through functional icon showing on touch LCD screen Cyan light source can...

Страница 15: ... 4 Slide the illuminator out of the chamber to the end 5 Find the plastic pad on the track underneath the illuminator one plastic pad per track 6 Hold the illuminator and press the plastic pad per hand and slightly slide the illuminator out of the track 7 For the new illuminator installation find the plastic pads on the track underneath the new illuminator Hold the illuminator press the plastic pa...

Страница 16: ...er to remove side screw as circled 2 Slowly lift the enclosure cover and toward approximately 5cm to take it off 3 Gently rotate UV lamps by hands approximately 90 degree till logo imprints and connector pins can be seen below to take off the lamps then exchange UV replacement s accordingly ...

Страница 17: ...to your wireless device through WIFI PC Notebook tablets smartphone 1 Open the internet wireless connectionin the control panel of your wireless process ends 2 Find MyWLAN and connect 3 From your wireless process end open a web browser On the webpage address site type in 192 168 1 66 then press enter 4 A dialogue for log on the connection is shown Login name admin Password 0000 Press Ok to log in ...

Страница 18: ...l Not Turn On There is a power cord connecting Slite 600 with UV transilluminator Check to see if the power cord is loose by sliding UV transilluminator out of cabinet to the end If so tightly plug the power cord back to UV transilluminator If still not turning on unplug the power cord and replace with other power cord hook up replaced power cord to UV transilluminator and plug into the power sock...

Страница 19: ...ns V Auto Focus V Filter Set Filter Turret Motor Driven 6 position EmissionFilter One standard set Fivefor optional order 595 nm EtBrStain Control Set Display Panel Build in 8 Touch TFT LCD Standalone Control Touch Screen Interface PC Control Interface None Image Storage USB Storage Wi Fi Lighting Set UV Transillumintor 20cm X 20cm V White Back Light V Epi White Light V Cyan Red illuminator Option...

Страница 20: ...TEL 886286921800 FAX 886286921860 7F No 239 Sec 1 Datong Rd Xizhi Dist New Taipei City 221 WARRANTY The warranty of PIE Corporation shall be of no force and effects if buyer has modified or damage the product TECHNICAL SUPPORTS Please contact your local PIE distributor for further assistance technical support in needed ...

Отзывы: