Pacific hydrostar 47906 Скачать руководство пользователя страница 2

Page 2

For technical questions, please call 1-800-444-3353.

SKU 47906

SAVE tHiS MAnUAL

Keep this manual for the safety warnings 

and precautions, assembly, operating, inspec-

tion, maintenance and cleaning procedures.  

Write the product’s serial number in the back 

of the manual near the assembly diagram (or 

month and year of purchase if product has no 

number).  Keep this manual and the receipt in 

a safe and dry place for future reference.

iMPOrtAnt SAFEtY 

inFOrMAtiOn

in this manual, on the labeling, and 

all other information provided with 

this product:

  this is the safety alert sym-

bol.  it is used to alert you 

to potential personal injury 

hazards.  Obey all safety mes-

sages that follow this symbol 

to avoid possible injury or 

death.

 

dAngEr indicates a 

hazardous situation 

which, if not avoided, will result 

in death or serious injury.
 

WArning indicates a 

hazardous situation 

which, if not avoided, could 

result in death or serious injury.
 

cAUtiOn, used with 

the safety alert 

symbol, indicates a hazardous 

situation which, if not avoided, 

could result in minor or moderate 

injury.
 

nOticE is used to 

address practices not 

related to personal injury.

 

cAUtiOn, without the 

safety alert symbol, is 

used to address practices not 

related to personal injury.

SAFEtY WArningS And 

PrEcAUtiOnS

 WArning read all safety warnings 

and instructions. 

Failure to follow the 

warnings and instructions may result 

in electric shock, fire and/or serious 

injury.   

Save all warnings and instructions 

for future reference.

read all instructions before use!

Keep work area clean

1. 

.  Cluttered areas 

invite injuries.

Observe work area conditions

2. 

.  Do not 

expose this pump to rain or submerge 

in water.  Keep work area well lighted.  

Do not use electrically powered pumps 

in the presence of flammable gases or 

liquids.

Keep children away

3. 

.  Children must 

never be allowed in the work area.  Do 

not let them handle Pump.

Use the right pump for the job

4. 

.   Do 

not attempt to force a small Pump to 

do the work of a larger industrial Pump.  

There are certain applications for which 

this Pump was designed.  It will do the 

job better and more safely at the rate for 

which it was intended.  Do not modify 

this Pump and do not use this Pump for 

a purpose for which it was not intended.

dress properly

5. 

.  Do not wear loose 

clothing or jewelry as they can be caught 

in moving parts.  Protective, electrically 

non-conductive clothes and non-skid 

footwear are recommended when work-

ing.  Wear restrictive hair covering to 

contain long hair.

Содержание 47906

Страница 1: ...served No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual may not...

Страница 2: ...ry CAUTION without the safety alert symbol is used to address practices not related to personal injury Safety Warnings and Precautions WARNING Read all safety warnings and instructions Failure to foll...

Страница 3: ...r reflexes are impaired while taking drugs If there is any doubt do not install the Pump RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS 120 VOLT NAMEPLATE AMPERES at full load EXTENSION CORD LENGT...

Страница 4: ...ety Code 25249 5 et seq The warnings cautions and instruc 22 tions discussed in this instruction manual cannot cover all possible con ditions and situations that may occur It must be understood by the...

Страница 5: ...d the warranty Foot Valve Check Valve Well Seal Shallow Well Pump To Household Water System Standing Water Level With Well Pump Off Pumping Water Level with Well Pump Operating Outlet Water Level Vert...

Страница 6: ...pump s housing Caution DO NOT INSERT fittings into the Intake Hole farther than 1 2 this can DAMAGE the Pump diminish Pump functions and or STOP water flow Keep the Head the height that the 8 pump dis...

Страница 7: ...gauge to insure that the rubber bladder maintains the required air pressure Make sure the intake pipe is fully 2 submerged before continuing Before starting the pump for the first 3 time prime it by...

Страница 8: ...in suction pipe 4 Inlet screen clogged 5 Prime pump 1 Reduce lift height 2 Submerge the inlet 3 Check pipe and seals 4 Clean screen 5 Only a low volume of water flows Inlet pipe is too small 1 Liquid...

Страница 9: ...uction line into water and re 4 prime If water is deeper than 26 ft then a deep well pump may be needed Motor runs but water is not pumping Improper priming 1 Air leakage 2 Vertical lift too high 3 Wa...

Страница 10: ...Y THE MANUFACTURER AND OR DISTRIBUTOR HAS PROVIDED THE PARTS DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER NOR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND T...

Страница 11: ...Page 11 For technical questions please call 1 800 444 3353 SKU 47906 Assembly Drawing REV 08f 09c...

Страница 12: ...ng a part from this drawing you must include the suffix A with the number Part Description Qty 1A Compression Tank 1 2A Pump Assembly 1 3A Hex Bolt 2 4A Hex Nut 2 5A Pressure Meter 1 6A Cable 1 7A Swi...

Страница 13: ...rty or for incidental contingent special or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the...

Отзывы: