Table 3 – Setting of output1 and output2:
Text SMS
Text, which will contain SMS confirming the output status change.
SMS ON
SMS command which will switch the output ON
SMS OFF
SMS command which will switch the output OFF
Call confirmation
Tel. number, which switch output will receive confirmation via call back only if output is switched ON
SMS
Tel. number, which switch output will receive confirmation via SMS if any change status on output
Timer
If the timer time set to a value other than 00:00:00, the output will be switched ON via call or SMS only for pre-
set time. After the countdown timer, the output is automatically switched off. Time format "hours: minutes:
seconds”. Maximum duration of the timer is 10 hours. Ex. 0:30:00 is set for 30 minutes.
Table 4 – Service Report Setting:
Automatic SMS
Will automatically send SMS at present time to phone numbers which enable service SMS.
Day
Day determines which day will be SMS send. Ex. Day = 1 means that the messages are sent each day.
Hour
Specifies the hour in which the SMS will be send out. Ex. 14 means that the SMS is sent within 14 hours (2pm)
Table 5 – Setting of entry/exit time:
Entry time
Delay timer before the SMS will be send out if the communicator not disarmed between this time. This function
not work on 24 Hours input setting
Exit time
The delay starts if the pre-set input (bellow) for Arm/Disarm activated table2 row 2 not work with SMS or call
control. This function not work on 24 Hours input setting
SMS OFF
SMS command which will switch the output OFF
Apply for input1
Allow entry a exit time for input1
Apply for input2
Allow entry a exit time for input2
Table 6 – Thermostat setting:
High limit
Set the temperature which will switch output OFF in heating mode and will switch output ON in cooling mode
Low limit
Set the temperature which will switch output ON in heating mode and will switch output OFF in cooling mode
Thermostat switch
relay1
Assign relay output
Thermostat switch
relay2
Assign relay output
Mode
Sets the thermostat in to heating or cooling mode
* The temperature can be controlled in the range of -20 to +99.9 ° C.
Table 7 – Setting the SMS temperature limits:
Temperature info
SMS
Will allows send SMS if the temperature reach the set limit
High limit
Set the temperature which will triggered SMS out if the reach set limit or higher
Low limit
Set the temperature which will triggered SMS out if the reach set limit or lower
Hysteresis
This setting determines the temperature at which the communicator will sends SMS Information about
exceeding upper or lower limits again the temperature is the upper limit for the difference: the upper limit -
hysteresis for the lower limit of the sum of: lower limit + hysteresis.
Example: the upper limit is set at 35 °, the lower limit to 20 °, hysteresis at 5 °. When exceeding
35 °communicator will send SMS report about exceeding the upper limit, then if the temperature drops below
30 ° C and then rises above 35 ° C, it is again sent out the SMS report about exceeded the upper limit.
If the temperature drops below 20 ° C, communicator will send SMS report about exceeding the lower limit, then
if the temperature increase up 25 ° C and then drop below 20 ° C, it is again sent out the SMS report about
exceeded the lower limit.
* The temperature can be controlled in the range of -20 to +99.9 ° C.