Setting of basic parameters DIN-3G communicator 

 
 

Description of configuration software for DIN-3G 

 
• The device name is used for naming-communicator. This name will be displayed at the beginning of each SMS that send DIN-3G. 
 
• Phone numbers - DIN-3G can communicate with up to six phone numbers with international code that you enter in this list 
 
• Setting Phone Numbers – allocation for individual numbers setting 
 
• Set input 1 and 2 - setting behaviour of inputs  
 
• Set the relay 1 and 2 - setting behaviour of outputs 
 
• System Time - synchronisation time with PC 
   
• Password - used to change the password for the program, and SMS commands (default password is 1234). To save the password, it is 
necessary to save the configuration, click Save to the device. Attention: The password must be four digits long and consist only digits. 
 
• Bottom Status Bar - displays the network operator, the current status of the network signal and battery firmware version DIN-3G store 
and process configuration. 
 
 
 

Advanced settings DIN-G3 configuration software 

 
• Starting value - setting the activation / deactivation, inputs and status outputs when communicator reset 
 
• Entry and exit time- setting of timers 
  
• Thermostat setting – setting of high and low limits include relay reaction 
 
• ON/OFF commands- setting the SMS commands for arming and disarming inputs 
 
• Service setting – setting of automatic status SMS and Information SMS temperature limits  
 
• Power cut- if enabled, the service authorization numbers receive SMS in the event of a main power 230V failure  
 
• Low battery - if enabled, the service authorization numbers receive SMS in case of low battery (25% or less) 
 
• Temperature Sensor - if enabled, the service authorization numbers receive SMS in case of disconnection or failure the sensor 
 
 
 
 
 
 

Table 1 – Phone Numbers: 

Inputs 1 and 2 

Set input 1 or input 2 to the alarm receiving phone number 

Outputs 1 and 2 

Set the number to control relay 1 or relay 2 via call. Beware, this function is not compatible with the function of 
activation and deactivation calling option – see function below the A / D 

Call 

The alarm will be reported via call  

SMS 

The alarm will be reported via SMS 

A/D 

Control the activation and deactivation inputs vial call. Beware, this function is not compatible with the output 
control call function. 

Service 

This number will be receiving service SMS reports* 

 
* Service SMS by default: information on lost / restore 230V can also enable automatic sending of SMS status if exceeding temperature 
set limits 
 
 

Table 2 - Setting of input1 and input2: 

Text SMS 

Entre the text which will receive if alarm 

Input reaction 

Connecting- SMS alarm if input connected to GND, disconnecting – SMS alarm if input disconnected from GND, 
Status Change – SMS alarm responding to connection and disconnection GND, ARM / DISARM – if input 
connected to GND, the communicator is disarm when not connected to GND, is arm. 

Input mode 

ARM / DISARM - SMS alarm is triggered only if communicator arm. 24 hours - input always send SMS (e.g. for 
the use of fire sensors, gas etc.). 

Delay 

Indicates how long must be GND connected or disconnected in input before SMS send out  

Relay1 ON 

When input activating SMS alarm input also switch output 1. The output reaction is subject to settings of output1  

Block 15 

The triggered input will be blocked to send SMS for next 15 minutes 

Содержание DIN-3G

Страница 1: ...voltage 230V AC The communicator is backed up by internal Li ion battery 3 7 V 550mAh Current consumption communicator connected to network approx 20 mA relays on 120mA battery charging 320mA Max cur...

Страница 2: ...etworking respectively another problem The PWR BAT and blue Network ON New Pre Pay SIM Card Activation 1 It is recommended to only use new standard SIM cards with no data stored The DIN 3G has been te...

Страница 3: ...he power connect the corresponding GSM antenna 2 After connecting the power supply and SIM card the module will go undergo a self test cycle While in this cycle the PWR BAT and Network Led s continuou...

Страница 4: ...Basic configuration window Advanced configuration window...

Страница 5: ...ce authorization numbers receive SMS in case of low battery 25 or less Temperature Sensor if enabled the service authorization numbers receive SMS in case of disconnection or failure the sensor Table...

Страница 6: ...exit time for input1 Apply for input2 Allow entry a exit time for input2 Table 6 Thermostat setting High limit Set the temperature which will switch output OFF in heating mode and will switch output O...

Страница 7: ...al input setting see table 11 SETR1 ABCDEFGH Change of output setting see table 12 SETTHERM ABCDEFGHIJK Change of thermostat setting see table 13 SETTEMP ABCDEFGHIJ Setting of monitoring temperature S...

Страница 8: ...5 minutes Input delay transient treatment can be adjusted from 0 2 to 9 9 seconds Table 12 Output settings Command SETR1 or SETR2 send SMS SETR1 ABCDEFGH Parameter A A 1 after the output switched on o...

Страница 9: ...ified service partner before using it Failure to do so might entail a risk of product malfunction or even a potential hazard to your health Recommendations for Safe use of product Always treat your pr...

Страница 10: ...for any damages The GSM Communicator was tested with SIM cards provided by Vodafone NZ Spark NZ 2Degrees NZ Telstra AU Optus AU Voda fone AU AT T USA T mobile USA Pacific GSM Limited cannot be held l...

Отзывы: