Pacific GSM DIN-3G Скачать руководство пользователя страница 1

DIN-3G 

3G Network Communicator 

Instructions: July 5, 2017, refers to the firmware version: 1.152N 

 

Pacific GSM company expanded its range of DIN mounted 
communicators for DIN-3G version of popular GSM DIN dialler 
GSM-DIN3. The new DIN-3G available in 230V AC, 110V AC, 
and also low 8-25V AC or DC version, so any electrical 
application can be quickly and easily switched or monitored 
through 3G network. 
Through DIN-3G communicator can be remotely controlled 
such as lighting, pumps, garage doors and gates. 
May indicate a fault, loss of liquid in tanks, emergency conditions, 
reboot servers or simply using a suitable sensor watch 
objects, spaces and objects. 
 
All easily through standard mobile phone  
 
DIN-3G module is a fully pre-programmed, for most common 
function (alarm report), just call the unit SIM number from phone 
which you want to contact if a DIN-3G input 1 connected to GND, 
DIN-3G will send you confirmation SMS with saved number and 
that is all. Furthermore, the protocol allows you to edit text, switching commands, and settings of maximum 
adaptation to your application. The options are twofold: either via USB-PC or SMS commands, please refer 
manual below 
 

Basic specification: 

 

 

DIN-3G communicator dimensions: 90 x 68 x 58 mm (H x W x D) 

 

UMTS  800/ 850/ 900/ 1900/ 2100 MHz 

 

GSM/EDGE 850/ 900/ 1800/ 1900 MHz 

 

Power supply voltage: 230V AC  

 

The communicator is backed up by internal Li-ion battery 3.7 V/550mAh 

 

Current consumption – communicator connected to network: approx. 20 mA, relays on 120mA, battery charging 320mA 

 

Max current consumption (GSM module transmits): peak of 1500mA max. 

 

Operating temperature: -20°C to +50°C 

 

2 logic inputs, active level GND. 

Input is designed for connection of potential-free contacts! 

 

1 input for digital temperature sensor with a measuring, range from -20°C to 125°C. 

(Temperature sensor sold separately with cable length 2m,3m and 5m) 

 

2 relay outputs 230V with load max 5A  

 

USB-PC configuration with USB cable (cable include in package)  

 

DIN-3G is designed in a dry environment. For outdoor installation, use the box with corresponding protection. 

 

6 authorized phone numbers can be set up 

 

Basic Features: 

 

 

Two universal inputs with adjustable reaction to change, connection or disconnection of the loop. 

 

Inputs can be named (SMS text). 

 

Each input can send 2 different TXT for remote status equipments 

 

Inputs can be use for arming/disarming the communicator from remote device 

 

Inputs option for entry and exit time 

 

In case it is necessary to have an input permanently enabled (the watchdog state), can be switched into mode 24h. loop. 

 

Input for digital temperature sensor with automatic output control (thermostat). 

 

Information SMS in case of exceeding the set temperature or the temperature drops below the set limit. 

 

Device Status, you can always check the status via SMS. 

 

Easy configuration USB-PC software or SMS commands 

Содержание DIN-3G

Страница 1: ...voltage 230V AC The communicator is backed up by internal Li ion battery 3 7 V 550mAh Current consumption communicator connected to network approx 20 mA relays on 120mA battery charging 320mA Max cur...

Страница 2: ...etworking respectively another problem The PWR BAT and blue Network ON New Pre Pay SIM Card Activation 1 It is recommended to only use new standard SIM cards with no data stored The DIN 3G has been te...

Страница 3: ...he power connect the corresponding GSM antenna 2 After connecting the power supply and SIM card the module will go undergo a self test cycle While in this cycle the PWR BAT and Network Led s continuou...

Страница 4: ...Basic configuration window Advanced configuration window...

Страница 5: ...ce authorization numbers receive SMS in case of low battery 25 or less Temperature Sensor if enabled the service authorization numbers receive SMS in case of disconnection or failure the sensor Table...

Страница 6: ...exit time for input1 Apply for input2 Allow entry a exit time for input2 Table 6 Thermostat setting High limit Set the temperature which will switch output OFF in heating mode and will switch output O...

Страница 7: ...al input setting see table 11 SETR1 ABCDEFGH Change of output setting see table 12 SETTHERM ABCDEFGHIJK Change of thermostat setting see table 13 SETTEMP ABCDEFGHIJ Setting of monitoring temperature S...

Страница 8: ...5 minutes Input delay transient treatment can be adjusted from 0 2 to 9 9 seconds Table 12 Output settings Command SETR1 or SETR2 send SMS SETR1 ABCDEFGH Parameter A A 1 after the output switched on o...

Страница 9: ...ified service partner before using it Failure to do so might entail a risk of product malfunction or even a potential hazard to your health Recommendations for Safe use of product Always treat your pr...

Страница 10: ...for any damages The GSM Communicator was tested with SIM cards provided by Vodafone NZ Spark NZ 2Degrees NZ Telstra AU Optus AU Voda fone AU AT T USA T mobile USA Pacific GSM Limited cannot be held l...

Отзывы: