- 11 -
The battery needs charging or there is a bad connection to the battery. Check the connections to the battery. If the
connections are good, try charging the battery.
MACHINE ERROR CODES
There is a bad connection to the Traction motor. Check all connections between the motor and the control system.
There is a bad connection to the Brush motor/motors. Check all connections between the motor/motors and the
control system.
The control system is being inhibited from driving.
Inspect Throttle System. Ensure that the throttle is in the rest position before switching on the machine. Check all
associated connectors and wiring.
A control system trip is indicated. Make sure that all connections are secure.
Inspect the Brake System. Ensure the brake is functioning properly. Check all associated connectors and wiring.
Excessive voltage has been applied to the control system. This is usually caused by a poor battery connection. Check
the battery connections.
The key switch is located on the control panel. When the machine is not in use, remove the key and store it in a secure location.
TURNING THE UNIT ON/OFF
CIRCUIT BREAKERS
The circuit breakers on the control panel protect the components from high amp-draw. In particular, the scrub head circuit will draw
too many amps when overloaded by improper application setup. Solution flow, floor surface, and down-pressure should be considered
when operating the machine (example: high down-pressure on a rough floor with no solution flow will overload the circuit).
Repeatedly tripping the breaker will cause the need for replacement.
BATTERY POWER LEVEL & FAULT INDICATOR
When switched to the ON position, the Battery Power Level Indicator illuminates indicating the battery charge level. A full charge is
indicated when all LEDs are lit. As the power level decreases, the LEDs go out from right to left.
When the battery charge is depleted, the last red LED will flash and the brush motor will turn off. The vacuum and traction drive will
continue to function allowing final water recovery and transport to the charging station.
NOTE
: Using AGM battery-equipped units after the last yellow LED goes out can reduce the life of the batteries.
NOTE
: After a fill charge, operate the machine for at least 30 minutes before recharging the batteries again. Do not leave the batteries
discharged overnight.
Содержание S-20
Страница 5: ...PAGE INTENTIONALLY BLANK...
Страница 25: ...20 RETURN TO TABLE OF CONTENTS PAGE INTENTIONALLY BLANK...
Страница 29: ...RETURN TO TABLE OF CONTENTS 24 PAGE INTENTIONALLY BLANK...
Страница 40: ...35 RETURN TO TABLE OF CONTENTS CONTROLS S 24XM TRACTION MODELS...
Страница 42: ...37 RETURN TO TABLE OF CONTENTS S 20HD CONTROLS...
Страница 50: ...45 RETURN TO TABLE OF CONTENTS S 20HD DISK SCRUB HEAD...
Страница 61: ...RETURN TO TABLE OF CONTENTS 56 PAGE INTENTIONALLY BLANK...
Страница 62: ...RETURN TO TABLE OF CONTENTS 57 DATE MAINTENANCE LOG...
Страница 63: ...58 RETURN TO TABLE OF CONTENTS DATE MAINTENANCE LOG...
Страница 66: ...www pacificfloorcare com...