CAUTION
FOR YOUR SAFETY -
Do not install or operate your Pacific Energy
Mirage without first reading and understanding this manual. Any
installation or operational deviation from the following instructions
voids the Pacific Energy Gas Stove Warranty and may prove
hazardous.
This appliance and its individual shutoff valve must be disconnected
from gas supply piping system during any pressure testing of that
system at test pressures in excess of 1/2 psig. (3.5 kPa)
This appliance must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to or
less than 1/2 psig. (3.5 kPa)
SAFETY
Due to high temperatures, this gas appliance should be
located out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of high
surface temperature and should stay away to avoid burns or
clothing ignition.
Young children should be carefully supervised when they
are in the same room as the appliance.
Clothing or other flammable material should not be placed
on or near the appliance.
Any grill, panel or door removed for servicing the unit must
be replaced prior to operating. Failure to do so may create a
hazardous condition.
Installation and repair should be done by a qualified service
person. The appliance should be inspected before use and at
least annually by a professional service person. More frequent
cleaning may be required due to excessive lint from carpeting,
bedding material, etc. It is imperative that control compart-
ments, burners and circulating air passageways of the appli-
ance be kept clean.
It is Pacific Energy’s policy that no responsibility is assumed by the
Company or by any of its employees or representatives for any
damages caused by an inoperable, inadequate, or unsafe condition
which is the result, either directly or indirectly, of any improper
operation or installation procedures.
MAINTENANCE
Caution:
Turn off gas and electrical power supply and allow ample
time for unit to cool before servicing appliance. It is recommended
that this appliance and venting should be inspected at least once a
year by a qualified service person.
Do not use this heater if any part has been under water. Immediately
call a qualified service technician to inspect the heater and to replace
any part of the control system and any gas control which has been
under water.
Annual Inspection:
a) Clean louvres and air passage ways of excessive lint build-up
from carpeting, bedding material, etc. The flow of combustion and
ventilation air must not be obstructed.
b) Remove glass panel and log set. Inspect logs and burner
assembly for lint and soot build-up. If excessive build-up of soot is
present, have a qualified serviceman inspect and adjust unit for
proper combustion. Clean logs and burner with a vacuum cleaner,
paying close attention to port on burner.
c) Check the pilot system for proper operation. (See Fig. #1)
d) Check that the chimney flue and its outlet are open and free from
blockage or debris.
e) Check glass panel gasket, replace if necessary.
Note:
The appliance area must be kept clear and free from
combustible materials, gasoline and other flammable vapours and
liquids.
Periodically:
a) Viewing glass may be cleaned with glass cleaner.
b) Exterior porcelain enamel finish may be cleaned with soap and
water.
Note:
Never use abrasives to clean this appliance.
ELECTRODE
BURNER
THERMOPILE
PILOT FLAME
Fig. # 1