background image

10 SUPER-SD1 

071111-20

Operation

CAUTION: 

 Never use gasoline, gasoline type lantern 

fuel, kerosene, charcoal lighter fl uid or similar liquids to 
start or "freshen up" a fi re in this heater.  Keep all such 
liquids well away from the heater while it is in use.

CAUTION:  Hot while in operation.  Keep children, 
clothing and furniture away.  Contact may cause 
skin burns.

Over Firing

Your PACIFIC ENERGY heater is designed formany 
years of trouble free operation. Over fi ring the appliance 
will shorten the life of the product. Failure to recitify an 
over fi ring condition can be hazardous and may void the 
manufacturer's warranty.

Wood Selection

This heater is designed to burn natural wood only. Higher 
efficiency and lower emissions generally result when 
burning air-dried seasoned hardwoods, as compared to 
softwoods or to green or freshly cut hardwoods.
Wood should be properly air dried (seasoned) for six 
months or more. Wet or undried wood will cause the fi re 
to smoulder and produce large amounts of creosote. 
Wet wood also produces very little heat and tends to go 
out often.

DO NOT BURN :

 

 

-Salt water wood  * 

 

-Treated wood

 

 

-Wet or green wood   

 

- C o a l / c h a r-

coal

 

 

-Garbage/Plastic  * 

 

-Solvents

*  These materials contain chlorides which will rapidly 
destroy metal surfaces and void warranty.

Do not burn anything but wood.  Other fuels, eg. charcoal, 
can produce large amounts of carbon monoxide, a taste-
less, odourless gas that can kill.  Under no circumstances 
should you attempt to barbecue in this heater.

How to Test Your Wood

Add a large piece of wood to the stove when it has a good 
large bed of coals.  It is dry if it is burning on more than 
one side within one minute.  It is damp if it turns black 
and lights within three minutes.  If it sizzles, hisses and 
blackens without igniting in fi ve minutes it is soaked and 
should not be burnt.

Lighting for the First Time

Curing of the Paint Finish

To achieve the best fi nish, the paint on your stove must 
be baked on.  When burning your stove for the fi rst 2-3 
times it is very important that the room be well ventilated.  

Open all windows and doors.  Smoke and fumes caused 
by the curing process may cause discomfort to some 
individuals.

Lighting a Fire

WARNING: Never use chemicals or any other volatile 
liquid to start a fi re.

1.  Adjust air control to position H (maximum fi ring rate) 

and open door.

2.  Place crumpled newspaper in the centre of the heater 

and criss-cross with several pieces of dry kindling.  
Add a few small pieces of dry wood on top.

3.  Ignite the paper and close the door.
4.  After the fi re has established itself, open the door and 

add a few small logs.  Close door.

5.  Begin normal operation after a good coal base exists 

and wood has charred.

Normal Operation

1.  Set air control to a desired setting.  If smoke pours 

down across the glass (waterfall effect) this indicates 
you have shut the control down too soon or you are 
using too low a setting.  The wide range control panel 
makes fi nding the desired setting for your application 
easy.  As every home's heating needs vary (ie. insu-
lation, windows, climate, etc.) the proper setting can 
only be found by trial and error and should be noted 
for future burns.

2.  To refuel, adjust air control to high, and give the fi re 

time to brighten.  Open the door slowly, this will prevent 
backpuffing.

3.  Use wood of different shape, diameter and length (up 

to 18").  Load your wood endwise and try to place the 
logs so that the air can fl ow between them.  Always 
use dry wood.

4.  Do not load fuel to a height or in such a manner that 

would be hazardous when opening the door.

5.  For extended or overnight burns, unsplit logs are 

preferred.  Remember to char the wood completely 
on maximum  setting before adjusting air control for 
overnight burn.

WARNING: Always keep loading door closed when 
burning. This heater is not designed for open door 
burning.

WARNING:  No alteration or modifi cation of the 
combustion air control assembly is permitted.  Any 
tampering will void warranty and could be very haz-
ardous.

WARNING:  Do not use grates or andirons to elevate 
the fuel.  Burn directly on the fi re bricks.  Replace 
broken or missing bricks.  Failure to do so may cre-
ate a hazardous condition.

Содержание SUPER 27 SPECTRUM

Страница 1: ...llationinstructions Contact local building or fire officials about restrictions and installation inspection requirements in your area TESTED and LISTED to CAN ULC S627 AND UL 1482 Meets the Environmen...

Страница 2: ...eosote 4 Formation and Need for Removal 4 Chimney Fires 4 In Case of a Chimney Fire 4 Avoiding a Chimney Fire 4 Assembly 5 Crate Removal 5 Optional Ash Cleanout System Install first 5 Pedestal Kit 5 L...

Страница 3: ...maintained in good condition Periodically inspect seals and replace if necessary Follow instructions included in the DR31 WDGKIT kit obtainable from your nearest Pacific Energy dealer 5 DOORGLASS Dono...

Страница 4: ...t be lived with Regular inspection and clean ing is the solution The use of dry seasoned wood and ample combustion air will help to minimize the buildup Chimney Fires The result of excessive creosote...

Страница 5: ...to bottom pallet 4 Place stove body carefully on its back 5 Using two 3 4 wrench remove 1 x 1 2 bolts and save for later use 6 Remove pallet retaining brackets from stove bottom Optional Ash Cleanout...

Страница 6: ...ooring using two 1 4 x 2 or longer lag screws Mobile Home Installation Warning Under no circumstances is this heater to be installed in a makeshift or temporary manner It may be fired only after the f...

Страница 7: ...Excel Ultra Black 4 Selkirk Metalbestos Model DS 8 Simpson Dura Vent Model DVL B As well as one of the following compatible chimney systems All parts 6 CANADA ONLY Security Pro Jet ICC Selkirk Energy...

Страница 8: ...tallation must meet all local codes Do not connect this unit to a chimney flue serving another appliance Minimum system height is 15 feet 4 6 m measured from base of appliance Double Wall Connector Us...

Страница 9: ...o be secured to the structure to prevent dislodging of the air duct Outside air may also be ducted from outside throughthe4 diameterknockoutholeintherearofthe pedestal or leg kit ash box enclosure If...

Страница 10: ...for the first 2 3 times it is very important that the room be well ventilated Open all windows and doors Smoke and fumes caused by the curing process may cause discomfort to some individuals Lighting...

Страница 11: ...ry replace with gasket 139 5availablefromyourPacificEnergydealer Re install baffle assembly in reverse order The two side pieces of insulation must be tight against the siderails Restarting After Exte...

Страница 12: ...ill al low the fan to turn on as the stove heats up to operating temperature It will also shut the blower off after the fire has gone out and the unit cooled to below a useful heat output range Manual...

Страница 13: ...latch Excessive Creosote Buildup See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t B...

Страница 14: ...ant Nickel CAST 31RSNI 10 Door Handle Assembly WODC 4147C 11 Boost Manifold 4105 12 Firebrick Set BRIC SSERA 13a Brick Rail Left Right SSER RAILSET 14 Replacement Baffle Kit SSER DBAKIT 15 Baffle Pin...

Страница 15: ...CAST 31NI Door Casting Radiant Nickel CAST 31RSNI 12 Door Handle Assembly WODC 4147C 13 Boost Manifold 4105 14 Firebrick Set BRIC SSERA 15a Brick Rail Left Right SSER RAILSET 16 Replacement Baffle Kit...

Страница 16: ...anding the basic functions of this design Traditionalwoodstoveshadabasiccombustion systemwhichallowedaconsiderableamountof heat energy to escape up the chimney as un burned gases and particulates smok...

Страница 17: ...ack 5 Using a 3 4 wrench remove 1 x 1 2 bolts and save for later use 6 Remove pallet retaining brackets from stove bottom Pedestal Kit 1 With the unit on its back and the removable cover facing up ali...

Страница 18: ...18 SUPER SD1 071111 20 NOTES...

Страница 19: ...L EXTENDED TO THE FRONT SIDES AND BACK AS INDICATED MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS COMPONENTS REQUIRED FOR MOBILE HOME AND ALCOVE INSTALLATION OUTSIDE AIR KIT AND ONE OF THE FOLLOWING LIS...

Страница 20: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 Allenby Rd Duncan B C V9L 6V8 Phone 250 748 1184 Web site http www pacificenergy net Printed in Canada...

Отзывы: