Label

MINIMUM CLEARANCE TO COMBUSTIBLES (MEASURED FROM INSERT BODY)
DÉGAGEMENT MINIMUM AUX COMBUSTIBLES
A)  

ADJACENT SIDEWALL/ 

203 MM / 8 IN

 PAROI 

LATÉRALE 

ADJACENTE

B) 

MANTEL 

660 MM / 26 IN

 

MANTEL WITH SHIELD 

508 MM / 20 IN

 

MANTEL AVEC LA PROTECTION

C) 

TOP FACING/ 

660 MM / 26 IN

 REVÊTEMENT 

SUPÉRIEUR

D) 

SIDE FACING/ 

203 MM / 8 IN

 REVÊTEMENT 

LATÉRAL

E) 

FIRING SIDE, CANADA 

457 MM / 18 IN

 

FIRING SIDE, U.S.A. 

406 MM / 16 IN

 

EPREUVE DU FEU

F) 

OTHER SIDES 

203 MM / 8 IN

 AUTRES 

CÔTÉS.

DATE OF MANUFACTURE

INSTALL AND USE ONLY IN ACCORDANCE WITH PACIFIC ENERGY’S INSTALLATION AND  OPERATING  INSTRUCTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT CODES, RESTRICTIONS AND  INSTALLATION INSPECTION IN 
YOUR AREA. INSTALL AND USE ONLY IN MASONRY OR  FACTORY BUILT  FIREPLACE. DO NOT  CONNECT THIS UNIT TO A 
CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
COMPONENTS REQUIRED FOR INSTALLATION : FULL FLUE LINER  CONFORMING TO CAN/ULC-S635 OR CAN/ULC-S640. 
IN U.S.A. FLUE LINER CONFORMING TO UL-1777 OR DIRECT FLUE  CONNECTION ASSEMBLY.
ELECTRICAL RATING 115V, 60HZ, 1.1 AMP. ROUTE POWER CORD AWAY FROM UNIT.
FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATE FIRE-BUILD WOOD FIRE DIRECTLY ON 
HEARTH. REPLACE GLASS ONLY WITH CERAMIC GLASS. INSPECT AND CLEAN CHIMNEY FREQUENTLY-UNDER 
CERTAIN CONDITIONS OF USE, CREOSOTE BUILDUP MAY OCCUR RAPIDLY.
OPTIONAL COMPONENT: MANTEL SHIELD PART# SINB.MSMBKA

MADE IN CANADA

F

M

A

M

J

J

A

S

O

N

D

2011

2012

2013

2014

2015

2016

U.S. ENVIRONMENTAL PROTECTION AGENCY
CERTIFIED TO COMPLY WITH JULY 1990
PARTICULATE EMISSION STANDARDS

J

LISTED SOLID WOOD FUEL FIREPLACE INSERT / APPAREIL DU 
TYPE INSERTION DE COMBUSTIBLE SOLIDE DE CHEMINÉE
CERTIFIED FOR USE IN CANADA AND U.S.A./CERTIFIE AU 
CANADA ET AUX ETATS-UNIS
TESTED TO / ÉPROUVÉ SELON:
ULCS628-93 / UL1482 (2010)
MODEL / MODÈLE:    SUMMIT INSERT

SERIES / SÉRIE:   B

050811 5050.7621 SINB-1

CAUTION

HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS.  
SEE NAMEPLATE AND INSTRUCTIONS.

MANUFACTURED BY:

PACIFIC ENERGY FIREPLACE PRODUCTS LTD.

2975 ALLENBY RD., DUNCAN, BC  V9L 6V8

CLEARANCE TO COMBUSTIBLE
CONSTRUCTION

F

ADJACENT SIDE W

A

LL

A

B

D

E

C

F

   WN#16831           ETL# 4001507

INSTALLEZ ET UTILISEZ SELON LES INTRUCTIONS D’INSTALLATION ET D’OPÉRATION DU PACIFIC ENERGY.  BÂTIMENT 
OU POMPIERS LOCAUX DE CONTACT AU SUJET DES CODES, RESTRICTIONS ET D’INSPECTION D’INSTALLATION 
DANS VOTRE SECTEUR. INSTALLEZ ET  EMPLOYEZ SEULEMENT EN MAÇONNERIE OU CHEMINÉE CONSTRUITE PAR 
USINE. NE RELIEZ PAS CETTE UNITÉ À UNE CONDUITE DE CHEMINÉE DE CHEMINÉE SERVANT UN AUTRE APPAREIL. 
MATERIEL REQUIS POUR L INSTALLATION:PLEIN REVÊTEMENT DE CONDUITE DE CHEMINÉE  CONFORMÉMENT À 
CAN/ULC-S635 OR CAN/ULC-S640. ÉLECTRIQUE 115V, 60HZ, 1.1 AMP. ITINÉRAIRE POWERCORD À PARTIR D’UNITÉ. 
POUR UTILISATION AVEC  COMBUSTIBLE AU BOIS  SEULEMENT. N’UTILISEZ PAS LA GRILLE OU N’ÉLEVEZ PAS LE 
FEU EN BOIS DE FIRE-BUILD DIRECTEMENT SUR LE FOYER. REMPLACES LA VITRE AVEC UNIQUEMENT DE LA VITRE 
CÉRAMIQUE.  INSPECTEZ ET NETTOYEZ LA CHEMINÉE FRÉQUEMMENT-DANS CERTAINES CONDITIONS D’UTILISATION, 
L’HABILLAGE DE CRÉOSOTE PEUT SE PRODUIRE RAPIDEMENT. 

The certfi cation label is located on the left side casing of the insert.

CERTIFICATION 

LABEL

Содержание SUMMIT INSERT SERIES - B

Страница 1: ...icials about restrictions and installation inspection requirements in your area IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER SAVE THESE INSTRUCTIONS TESTED and LISTED to ULC S628 UL 1...

Страница 2: ...a Chimney Fire 15 Maintenance 16 Baffle Removal 16 Appendix A 17 Understanding Operating Your Pacific Energy Stove 17 Troubleshooting 18 Firebrick Installation 19 Replacement Parts 20 Label 23 NOTE WE...

Страница 3: ...nsitivity SAFETY NOTICE If this stove is not properly installed a house fire may result For your safety follow the instal lation directions Consult local building or fire officials about restrictions...

Страница 4: ...t combustible floor Ember protection Combustible floor in front of the fireplace insert must be protected from hot embers by non combustible material extend ing 16 USA and 18 CANADA to the firing side...

Страница 5: ...6 25 3 8 27 9 16 B A 28 7 8 18 10 7 8 21 6 5 8 12 1 4 22 15 16 9 1 8 Mantel Clearances WITHOUT SHIELD WITH SHIELD A 26 20 B 23 1 2 18 MANTEL CLEARANCE CHART A B 12 4 REG SURROUND O S SURROUND A 48 3 4...

Страница 6: ...wood burning use Check for creosote build up or other obstructions especially if it has not been in use for some time Have chimney swept Theexistingfireplacedamperistobelockedopenorremoved completely...

Страница 7: ...stove cement and insert into collar Screw in fasteners to secure 8 Attach a rain cap to the end of the liner A storm collar may be used if desired 9 Reattach casing top with screws previously removed...

Страница 8: ...let or outlet ports This includes the circulating air chambers in a steel fireplace or metal heat circulator 5 Alteration of the fireplace in any manner is not permitted with the following exceptions...

Страница 9: ...ners of the trim and tighten screws Ensure the mitred corners fit tightly and evenly Fig 9 4 Slide the assembled trim over the surround from the top Fig 8 5 Tighten the retaining screws at the bottom...

Страница 10: ...h lip Ensure that the electric supply cord is located in the slots in the base of the surround 11 Once the surround is fastened to the insert in order to maximizeheatedairdischargeefficiency thesurrou...

Страница 11: ...he wires from the fans LHS RHS and thermal snap switch Take note of where the wires are routed and secured They must be positioned correctly to avoid damage 4 Loosen the two bolts that secure the ash...

Страница 12: ...itch Fig 30 refit ash lip sides and top Ensure that the power cable is correctly routed through the surround and it is not touching the firebox side Wire placement is important to prevent damage to wi...

Страница 13: ...as charred Normal Operation 1 Set air control to desired setting If smoke pours down across the glass waterfall effect this indicates you have shut the control down too soon or you are using too low a...

Страница 14: ...or or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed theyshouldberetainedintheclosedcontain...

Страница 15: ...occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire 1 Highest smoke densities occur when a large amount of wood is added to a bed of hot coals and the air i...

Страница 16: ...y other volatile liquid to start a fire Do not burn garbage or flammable fluids such a gasoline naptha or engine oil We strongly recommend that smoke detectors be installed 2 Remove ashes frequently E...

Страница 17: ...t acts as a heat storage and the thermalinsulationkeepsthecombustionzonehot Active flamingtakesplaceduringthefirstpartoftheburn During this stage heat is stored in the mass of the unit and is later re...

Страница 18: ...e Creosote Buildup See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t Burn Overnight...

Страница 19: ...1 2 X 1 1 4 102 mm x 115 mm x 32 mm 3245 501 Summit Insert Wood Stove This package contains 17 full size firebricks as well as 7 various cut size bricks With the woodstove in the upright position ins...

Страница 20: ...rched Brushed Nickel CAST 46BNA 23 Door Handle Assembly c w Wood Handle and Nut WODC 4147C 24 Baffle Pin SSER 125001 25 Brick Rail Set 2 pcs required SUMM RAILSET 26 Baffle Kit includes side insulatio...

Страница 21: ...SINB BODY 190112 24 21 2 1 7 27 6 30 3 24 12 31 13 30 18 19 20 21 9 10 17 15 14 29 5 4 8 16 11 23 22 25 25 28 31 31 32 33 34 26 26 35 35 31 26 26 Fig 32...

Страница 22: ...22 SINB BODY 190112 24 NOTES...

Страница 23: ...ED TO COMPLY WITH JULY 1990 PARTICULATE EMISSION STANDARDS J LISTED SOLID WOOD FUEL FIREPLACE INSERT APPAREIL DU TYPE INSERTION DE COMBUSTIBLE SOLIDE DE CHEMIN E CERTIFIED FOR USE IN CANADA AND U S A...

Страница 24: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD Technical Support 1 250 748 1184 www pacificenergy net 2975 Allenby Rd Duncan B C V9L 6V8 Printed in Canada...

Отзывы: