071111-20
SUPER-SD1 19
Label
CERTIFIED FOR CANADA AND U.S.A.
LISTED ROOM HEATER, SOLID FUEL TYPE.
ALSO FOR USE IN MOBILE HOMES
TESTED TO CAN/ULC S627-M93 AND UL 1482-98
ALDERLEA T5
MODEL SERIES D:
SUPER 27 SPECTRUM CLASSIC
WN# 16408
250509 5050.75
SUP1-A2
A. SIDEWALL TO UNIT
18 in. / 455 mm
14 in. / 355 mm
14 in. / 355 mm
14 in. / 405 mm
16 in. / 405 mm
16 in. / 405 mm
B. BACKWALL TO UNIT
12 in. / 305 mm
8 in. / 200 mm
5 in. / 127 mm
5 in. / 127 mm
10 in. / 255 mm
8 in. / 200 mm
C. CORNER TO UNIT
11 in. / 280 mm
11 in. / 280 mm
4 in. / 102 mm
4 in. / 102 mm
N/A
8 in. / 200 mm
D. SIDEWALL TO CONNECTOR
27 in. / 685 mm
23 in. / 585 mm
22.5 in. / 570 mm 22.5 in. / 570 mm 24.5 in. / 620 mm 24.5 in. / 620 mm
E. BACKWALL TO CONNECTOR 19 in. / 485 mm
15 in. / 380 mm
11.5 in. / 292 mm 11.5 in. / 292 mm 16.5 in. / 420 mm 14.5 in. / 370 mm
F. CORNER TO CONNECTOR
22 in. / 560 mm
22 in. / 560 mm
14.5 in. / 370 mm 14.5 in. / 370 mm
N/A 18.5 in. / 470 mm
DO NOT REMOVE THIS LABEL
• INSTALL AND USE IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.
• CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS, INSTALLATION PERMIT AND INSPECTION IN
YOUR AREA.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE (USA. ONLY).
• USE 6 INCH / 150MM DIAMETER MINIMUM 24 MSG BLACK OR LISTED CONNECTOR.
• CONNECT TO A LINED MASONRY CHIMNEY SUITABLE FOR USE WITH SOLID FUELS.
• DO NOT OBSTRUCT THE SPACE BENEATH THE HEATER.
• SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED WHEN PASSING
A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.
• DO NOT PASS A CHIMNEY CONNECTOR THROUGH A COMBUSTIBLE WALL OR CEILING.
• MINIMUM CLEARANCE BETWEEN SINGLE WALL CHIMNEY CONNECTOR AND COMBUSTIBLE MATERIALS-
18INCHES/455MM. CLEARANCE MAY BE REDUCED BY THE USE OF LISTED PIPE SHIELDS, WALL PROTECTORS OR
OTHER MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS.
HORIZONTAL CONNECTOR NOT PERMITTED IN MOBILE HOMES
AS TESTED - PIPE SHIELD MAY BE REQUIRED BY LOCAL AUTHORITIES.
* COMBUSTIBLE ALCOVE SIZE : DEPTH - 4 FT. / 1.22 M MAXIMUM, HEIGHT 7 1/2 FT. / 2.3 M MINIMUM
COMBUSTIBLE FLOOR MUST BE PROTECTED BY A CONTINUOUS NON-COMBUSTIBLE MATERIAL EXTENDED TO THE
FRONT, SIDES AND BACK AS INDICATED.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
• COMPONENTS REQUIRED FOR MOBILE HOME AND ALCOVE INSTALLATION: OUTSIDE AIR KIT, AND ONE OF THE
FOLLOWING LISTED CONNECTORS: SECURITY MODELS DP OR DC, OLIVER MACLEOD MODEL PV, ENERGY VENT
E VENT, SELKIRK METALBESTOS MODEL DS, METAL FAB MODEL DW, AMERI-TEC MODEL DBSP, INDUSTRIAL
CHIMNEY MODEL EXCEL ULTRA-BLACK, OR SIMPSON DURA-VENT MODEL DVL IN COMBINATION WITH ONE OF THE
FOLLOWING COMPATIBLE CHIMNEY SYSTEMS: APPLIANCE MUST BE INSTALLED WITH PEDESTAL OR LEG KIT
ATTACHED.
IN CANADA - SECURITY MODEL S2100, OLIVER MACLEOD PROJET MODEL HT 3000, SELKIRK SENTINEL MODEL CF,
INDUSTRIAL CHIMNEY MODEL EXCEL 2100.
IN USA - SECURITY MODEL ASHT OR S2100, OLIVER MACLEOD MODEL 3103 OR HT 3000, SELKIRK METALBESTOS
MODEL SS II, METAL FAB MODEL 2100, AMERI-TEC MODEL HS, INDUSTRIAL CHIMNEY MODEL EXCEL 103HT,
SIMPSON DURA-VENT MODEL DURA/PLUS AND DURA TECH.
USE COMPONENTS SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS.
• OPTIONAL COMPONENTS - WATER COIL (CANADA ONLY), FAN KIT #SSER.BLOW, FAN ELECTRICAL RATING: 115V,
60HZ, 80WATTS. DO NOT ROUTE POWER CORD BENEATH HEATER.
• CAUTION: RISK OF EXCESSIVE TEMPERATURES - KEEP ASH DUMP CLOSED DURING FIRING OF THE HEATER.
• OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY.
• KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS WELL AWAY FROM HEATER.
• REPLACE GLASS ONLY WITH CERAMIC GLASS.
MADE IN CANADA
J F M A M J J A S O N D
2009 2010
2011
2012 2013
2014
DATE OF MANUFACTURE
MANUFACTURED BY:
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN
BURNS. SEE NAMEPLATE AND INSTRUCTIONS.
U.S. ENVIRONMENTAL PROTECTION AGENCY
CERTIFIED TO COMPLY WITH
JULY, 1990, PARTICULATE EMISSION
STANDARDS
WH-
CAUTION
IN CANADA
G.
18 INCHES / 455 MM
H.
8 INCHES / 200 MM
I.
8 INCHES / 200 MM
IN U.S.A.
G.
16 INCHES / 405 MM
H.
5 INCHES / 127 MM
I.
0 INCHES / 0 MM
* ALCOVE
INSTALLATION
USING
DOUBLE WALL
CONNECTOR
RESIDENTIAL INSTALLATION
USING SINGLE WALL CONNECTOR
MOBILE HOME
INSTALLATION
USING
DOUBLE WALL
CONNECTOR
VERTICAL CONNECTOR HORIZONTAL CONNECTOR VERTICAL CONNECTOR HORIZONTAL CONNECTOR
RESIDENTIAL CLOSE CLEARANCE
INSTALLATION
USING DOUBLE WALL CONNECTOR
Содержание SPECTRUM CLASSICDESIGN-D
Страница 18: ...18 SUPER SD1 071111 20 NOTES...