Important Note for the Commonwealth of Massachusetts: 

 

From Massachusetts Rules and Regulations 248 CMR 5.08: 

 

(a) 

For all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, 

including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the 

area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied. 

 

1. 

INSTALLATION OF CARBON MONOXIDE DETECTORS.  At the time of installation of the side wall horizontal vented gas fuelled equipment, the 

installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the 

gas equipment is to be installed, in addition, the installing plumber or gas fitter shall observe that a battery operated or hard-wired carbon monoxide detector with 

an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fuelled equipment.  It shall be the 

responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard-wired carbon monoxide detectors.   

 

a. 

In the event that the side wall horizontally vented gas fuelled equipment is installed in a crawl space or an attic, the hard-wired carbon monoxide detector 

with alarm and battery back-up may be installed on the next adjacent floor level. 

 

b. 

In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall have a period of thirty (30) days 

to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall 

be installed. 

 

2. 

APPROVED CARBON MONOXIDE DETECTORS.  Each carbon monoxide detector as required in accordance with the above provisions shall comply 

with NFPA 720 and be ANSI/UL 2034 listed as IAS certified. 

 

3. 

SIGNAGE.  A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above 

grade directly in line with the exhaust vent terminal for the horizontally vented gas fuelled heating appliance or equipment.  The sign shall read, in print size no less 

than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW.  KEEP CLEAR OF ALL OBSTRUCTIONS”. 

 

4. 

INSPECTION.  The state or local gas inspector of the side wall horizontally vented gas fuelled equipment shall not approve the installation unless, upon 

inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.089(2)(a) 1 through 4. 

 

(b) 

EXEMPTIONS.  The following equipment is exempt from 248 CMR 5.089(2)(a) 1 through 4. 

1. 

The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and  

2. 

Product Approved side wall horizontal vented gas fuelled equipment installed in a room or structure separate from the dwelling, building or structure used in 

whole or in part for residential purposes. 

 

(c) 

MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM PROVIDED.  When the manufacturer of Product Approved side wall 

horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the 

manufacturer for installation of the equipment and the venting system shall include:  

1. 

Detailed instructions for the installation of the venting system design or the venting system components; and 

2. 

A complete parts list for the venting system design or venting system. 

 

(d) 

MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED.  When the manufacturer of a Product Approved 

side wall horizontally vented gas fuelled equipment does not provide the parts for venting the fuel gases, but identifies “special venting systems”, the following 
requirements shall be satisfied by the manufacturer. 

1. 

The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and 

2. 

The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation 

instructions. 

 

(e)) 

A copy of all installation instructions for all Product Approved side wall horizontally vented gas fuelled equipment, all venting instructions, all parts 

lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

 

Содержание GESM.BODYA

Страница 1: ...tely call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier cal the fire department Installation and service must be performed by...

Страница 2: ...rectly in line with the exhaust vent terminal for the horizontally vented gas fuelled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT D...

Страница 3: ...Venting Components 21 Plumbing and Electrical 22 Gas Supply 23 Gas Pressure Check 23 Gas Pressure Testing Procedure 24 Pilot Adjustment 24 Propane Conversion 25 Door Installation Removal 26 Fan Insta...

Страница 4: ...liance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less...

Страница 5: ...ing glass is provided with the appliance and shall be installed If the barrier becomes damaged the barrier shall be replaced with the manufacture s barrier for this appliance Any grill panel or door r...

Страница 6: ...pay close attention to all Safety Warnings The manual contains important information on the unit s safe operation and maintenance When lit for the first time the fireplace will emit a slight odour fo...

Страница 7: ...he gas valve and stepper motor Transmitter Remote Control with LCD Display The Proflame Transmitter uses a streamline design with a simple button layout and informative LCD display Fig 1 The transmitt...

Страница 8: ...then press again the button SW1 to exit the synchronization phase The system is now initialized IFC Module The Proflame 2 Integrated Fireplace Control IFC board is a device that allows the automatic...

Страница 9: ...ommand Turn off the Appliance With the system ON press the ON OFF Key on the Transmitter The Transmitter LCD display will only show the room temperature At the same time the IFC will be commanded to t...

Страница 10: ...the transmitter will change to show that the room thermostat is ON and the set temperature is now displayed Fig 7 To adjust the set point press the up or down arrow keys until the desired set point t...

Страница 11: ...Use the Up Down Arrow Keys Fig 1 to turn on off or adjust the fan speed fig 10 A single beep will confirm reception of the command Continuous Pilot Intermittent Pilot CPI IPI selection With the system...

Страница 12: ...t etc When the IFC batteries are low a double beep will be emitted from the IFC board when it receives a command from the transmitter This is an alert for a low battery condition for the IFC board Whe...

Страница 13: ...emblies for soot buildup If excessive buildup of soot is present have a qualified service person inspect and adjust unit for proper combustion Clean burners with a brush or vacuum cleaner paying close...

Страница 14: ...14 OWNER S INFORMATION Lighting Instructions...

Страница 15: ...15 INSTALLER INFORMATION Fireplace Dimensions ESTEEM ESTATE Figure 14 Estate Dimensions Figure 13 Esteem Dimensions...

Страница 16: ...STEEM ESTATE ENCLOSED SIDE WALL 1 75 1 75 ENCLOSED BACK WALL NCR NCR ENCLOSED CEILING 4 4 ENCLOSED FRONT WALL NCR NCR EXPOSED SIDE WALL 8 8 VENT ENCLOSURE 1 1 EXTERIOR SOFFIT 30 30 NCR STANDS FOR NO C...

Страница 17: ...is to be installed location of vent system and where gas supply piping may be plumbed Various installations are possible such as into an existing wall a corner a built in wall or a wall projection Du...

Страница 18: ...and then pressing it into place Note Install screen insuring the step faces inward 3 Install the surround front by positioning it so as to clear the notches and secure by applying a downward pressure...

Страница 19: ...justment from this chart Note The vent must not exceed a total length of 35 feet Any combination of rise and run may be used but must be constrained to the boundaries of this chart A Maximum of three...

Страница 20: ...20 INSTALLER INFORMATION Figure 17 Venting This fireplace is certified for use with 4 x 6 5 8 coaxial venting components only It is permitted to only use certified venting for this appliance...

Страница 21: ...components from different manufacturers is inadvisable Venting Components Figure 1 4 x6 5 8 Rigid Piping Cross Reference Chart Figure 21 4 x6 5 8 Rigid Piping Cross Reference Chart Figure 22 4 x6 5 8...

Страница 22: ...ng that extends out of the unit as seen in Figure 21 Please see the gas supply section for requirements of the gas supply A gas shut off valve is located inside the fireplace and may be accessed by re...

Страница 23: ...must be installed in the gas supply line going to the gas control valve to minimize the possibility of any loose scale or dirt within the gas supply line from entering the control valve Check local co...

Страница 24: ...n the valve which can be seen in Figure 25 After locating test ports loosen the screws within the ports using a flat tip screwdriver 3 Attach pressure gauge to the test ports 4 Turn gas supply back on...

Страница 25: ...rifice to ensure a proper seal when installed To replace the pilot orifice you will need to remove the pilot hood which is held in place by a spring First remove the spring and then remove the hood by...

Страница 26: ...ccess panel to attach the fan to the unit as in Figure 29 5 Reconnect the gas supply and power and push the inner firebox back into the fireplace cavity Installation before fireplace installation 1 Re...

Страница 27: ...box seen in Figure 33 Removal 1 Remove the baffle by removing screws securing the front edge of the baffle seen in Figure 33 After removing the two screws you can slide the baffle out of the fireplace...

Страница 28: ...r Deflector Burner Tray Installation Removal Installation Place the burner tray in the fireplace and secure with 4 screws using a screwdriver as seen in figure 35 Removal Remove the 4 screws seen in f...

Страница 29: ...ks in front of the front log to hide the burner as seen in Figure 42 Note Do Not Block Burner Ports with Embers Removal 1 Remove embers from fireplace 2 Lift the decorative log off of the front log an...

Страница 30: ...ace and secure with 4 screws using a screwdriver as seen in figure 45 Removal Remove the 4 screws seen in figure 45 using a screwdriver and remove the burner tray Glass Installation To install the gla...

Страница 31: ...would result in flames that cause soot See Page 19 for optimum restrictor position To adjust the damper loosen the two screws that hold the air deflector in place Slide the damper down to a position...

Страница 32: ...orcelain Panel Set Coffee Bean GASC PNSPCBA Porcelain Panel Set Copper GASC PNSPCUA Burner Set required Log Burner Set GASC SBRNLOGA Glass Burner Set GASC SBRNGLA Optional Components Broadway Blower K...

Страница 33: ...NSTALLER INFORMATION Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Wiring Diag...

Страница 34: ...______ __________________________________________________________________________________________________ ______________________________________________________________________________________________...

Страница 35: ...35 INSTALLER INFORMATION...

Страница 36: ...Technical support 1 250 748 1184 Web site www pacificenergy net 2975 Allenby Rd Duncan BC V9l 6V8...

Отзывы: