CLEARANCES TO SIDE AND BACK STANDOFFS/ DÉGAGEMENTS                                                        0 in. / 0 mm

C. CORNER TO SIDEWALL/ COIN AU MUR LAT. 

   

                                            3.1 in. / 79mm

D. FRAMING OPENING/ OVERTURE DE CADRAGE  

                                             56 in./1.42m

E. CEILING TO UNIT/ DU PLAFOND AU FOYER  

                                                                          38-3/4 in. / 986mm

NON-COMBUSTIBLES ONLY IN THE SPACE ABOVE UNIT TO CEILING, NOT INCLUDING 

APPROVED FRAMING / NON-COMBUSTIBLES SEULEMENT AU-DESSUS FOYER À PLAFOND 

F.  BASE OF UNIT TO MANTEL/ BASE DE L’UNITÉ AU MANTEAU                         

                                                                

G. EMBER PROTECTION FROM FRONT OF UNIT/ PROTECTEUR de PLANCHER À 

L’AVANT DU FOYER                     

 

 

     18 in. / 457 mm

H. EMBER PROTECTION TO SIDE OF UNIT/ PROTECTEUR de PLANCHER AU CÔTÉ 

DU FOYER                                                                                                                                                   8 in./203 mm

IN USA: (Type 1 floor protector - approved to UL1618)Equal to Minimum 20GA steel  

DO NOT REMOVE THIS LABEL/ NE RETIREZ PAS CETTE IQUETTE

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS/ DÉGAGEMENTS MINIMUMS AUX MATÉRIAUX COMBUSTIBLES

SN-

100003892

250423

             MANTEL HEIGHT MUST  BE MEASURED FROM THE BASE OF THE UNIT AS FOLLOWS: 

48 1/8 in.(1.22m) FOR ALL MANTEL DEPTHS FROM 2”(51mm) TO 12”(305mm)./// 

LA HAUTEUR DU MANTEAU, MESURÉE DE LA BASE DE L’APPAREIL, DOIT ÊTRE DE 48-1/8po (1,22 m) 

POUR LES MANTEAUX AYANT UNE PROFONDEUR DE 2 po (51 mm) À 12 po (305 mm).

***

***

MODEL/ MODÈLE:  

FP25 LE       FP25AR LE       

LISTED FACTORY BUILT FIREPLACE, also for use in Mobile Home.

CERTIFIED TO / CERTIFIÉ POUR:

 ULC S610 AND UL 127 for 

CANADA AND U.S.A. 

ETL#4001507

Refer to Intertek’s Directory of Building Products for detailed information

• •  LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA - CHEMINÉE HOMOLOGUÉE ULC-S-629, 

LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA - CHEMINÉE HOMOLOGUÉE ULC-S-629,  

•  INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION FOURNIES AVEC LE FOYER.

•  LES PARTIES DU FOYER INCORPORANT DES CONDUITS CHAUDS OU FROIDS DOIVENT ÊTRE ENCHÂSSÉES, CONFORMÉMENT AUX IN-

STRUCTIONS D’INSTALLATION ET D’UTILISATION FOURNIES AVEC LE FOYER.

•  CONTACTEZ LES AGENTS LOCAUX DU CODE DU BÂTIMENT OU DU SERVICE-INCENDIE POUR LES RESTRICTIONS, PERMIS 

D’INSTALLATION ET EXIGENCES D’INSPECTION DANS VOTRE RÉGION.

•  NE RACCORDEZ PAS CE FOYER À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE APPAREIL.

•  NE PAS OBSTRUER PAS LES OUVERTURES DEVANT LE FOYER, NI RESTREINDRE L’ALIMENTATION D’AIR NÉCESSAIRE POUR LE FONC-

TIONNEMENT NORMAL DU FOYER, TEL QUE SPÉCIFIÉ DANS LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION FOURNIES AVEC 

L’APPAREIL. LA PROVISION INADEQUATE D’AIR POUR COMBUSTION, MAI DE VENTILATION ET DILUTION A POUR RESULTAT L’OPERATION 

DANGEREUSE DE CECI ET AUTRES APPAREILS.

•   VOIR LE CODE DU BÂTIMENT LOCAL ET LES INSTRUCTIONS DU FABRICANT, POUR LES PRÉCAUTIONS EXIGÉES LORSQU’UNE CHEMINÉE 

TRAVERSE UN MUR OU PLAFOND EN MATÉRIAUX COMBUSTIBLES.

•  REMPLACEZ LA VITRE SEULEMENT PAR UNE VITRE EN CÉRAMIQUE. •  LA SOUFFLERIE CLASSEMENT ELECTRIQUE 115V, 60 Hz, 1.1AMP

•  CETTE CHEMINEE n’A pas ETE ESSAYEE AVEC UN UNVENTED JOURNAL DE GAZ A REGLE. POUR REDUIRE LE RISQUE DE FEU OU BLES

-

SURE, LE PAS INSTALLE UN UNVENTED JOURNAL DE GAZ A REGLE DANS CHEMINEE. 

•   UTILISEZ SEULEMENT AVEC LA PORTE DE CHARGEMENT FERMÉE. NE L’OUVREZ QUE POUR ALIMENTER LE FEU.

•  CE FOYER PEUT ÊTRE INSTALLÉ DANS UNE MAISON PRÉFABRIQUÉE. UTILISER DU BOIS SOLIDE SEULEMENT.

•  POUR COMBUSTIBLE SOLIDE SEULEMENT.

•   COMPOSANTS OPTIONNELS: KIT DE CONDUITS DE DISTRIBUTION DE CHALEUR (PIÈCE no WODC.RHKA).

•   UTILISEZ LES COMPOSANTS SPÉCIFIÉS DANS LES INSTRUCTIONS D’INSTALLATION DE PACIFIC ENERGY.

MANUFACTURED BY/ FABRIQUÉ PAR :

PACIFIC ENERGY FIREPLACE PRODUCTS 

LTD.

2975 ALLENBY RD., DUNCAN, BC  V9L 6V8

MADE IN CANADA 

/ FABRIQUÉ AU CANADA

U.S. ENVIRONMENTAL PROTECTION AGENCY 

Certified to comply with 2020 particulate 

emission standards, 

using Cordwood. 

Tested to ASTM 3053

1.4

g/hr.

DATE OF MANUFACTURE

• •    ALSO FOR USE IN MANUFACTURED HOMES WITH SOLID WOOD FUEL ONLY 

•  INSTALL AND USE IN ACCORDANCE WITH THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE APPLIANCE

•  AREAS OF THE FIREPLACE INCORPORATING WARM OR COLD AIR DUCTS SHALL BE ENCLOSED IN ACCORDANCE WITH THE INSTALLA-

TION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE APPLIANCE.  

•  CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS, INSTALLATION PERMIT AND INSPECTION IN YOUR AREA. 

•  DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE 

•  DO NOT OBSTRUCT THE OPENINGS IN FRONT OF THE FIREPLACE OR OTHERWISE RESTRICT SUPPLY AIR NECESSARY FOR NORMAL 

FIREPLACE OPERATION AS SPECIFIED IN INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE APPLIANCE. INADEQUATE 

AIR SUPPLY FOR COMBUSTION, VENTILATION AND DILUTION MAY RESULT IN DANGEROUS OPERATION OF THIS AND OTHER APPLIANCES.

•  CHIMNEY SYSTEM MUST BE LISTED TO: ULC S-629 IN CANADA / UL-103 HT IN USA    - 

ULC S-629 IN CANADA / UL-103 HT IN USA    - SEE LOCAL BUILDING CODE AND MANUFACTURER'S 

INSTRUCTIONS FOR PRECAUTIONS REQUIRED WHEN PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.    

•  OPTIONAL COMPONENTS: REMOTE HEAT KIT PART# WODC.RHKA. 

•  USE SOLID WOOD FUEL ONLY. OPERATE ONLY WITH FEED DOOR CLOSED.  OPEN TO FEED FIRE ONLY.

•  BLOWER ELECTRICAL RATING 115V, 60HZ, 1.1AMP   • REPLACE GLASS ONLY WITH 5mm CERAMIC GLASS.

•  DO NOT USE OR INSTALL COMPONENTS OR PRODUCTS NOT SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS. 

•  DO NOT USE A FIREPLACE INSERT OR OTHER PRODUCTS NOT SPECIFIED FOR USE WITH THIS PRODUCT.

• 

THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET. TO REDUCE RISK OF FIRE OR INJURY, DO NOT INSTALL AN 

UNVENTED GAS LOG SET INTO FIREPLACE.  

•  THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. 

•        - CONSULT THE OWNER’S MANUAL FOR FURTHER INFORMATION.

•  IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTANT WITH THE OPERATING 

INSTRUCTIONS IN THE OWNER’S MANUAL.

C

D

E

G

F

CAN.

U.S.A.

H

H

EPA Certified Emissions

1.4 grams per hour

LHV Tested Efficiency 1

72%

HHV Tested Efficiency 2

67%

EPA BTU Output 3

11,000 to 51,500 btu/hr

Peak BTU/Hr Output 4
Maximum Wood Length

17 inches

Ideal Wood Length 

16 inches

Fuel

Seasoned Cord wood

1 Weighted Average Lower Heating Value (LHV) efficiency as 
tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. LHV assumes the moisture is 
already in a vapour state so there is no loss of energy
2 Weighted Average Higher Heating Value (HHV) efficiency 
as tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. HHV includes the energy required 
to vaporize the water in the fuel
 3 The range of BTU outputs is based on efficiency using CSA 
B415 Performance testing of solid-fuel-burning heating appli-
ances and burn rates from the low and high EPA tests using 
Douglas Fir dimensional lumber.

Efficiency and BTU Output

This heater meets the U.S. Environmental Protection Agency's 2020 Cord wood emission limits for wood 
heaters sold after May 15, 2020 Tested to ASTM 3053. 

Under specific test conditions this heater has been shown to deliver heat at rates ranging from 

11,000 to 

51,500Btu/hr.

  Emissions testing was performed by PFS-TECO Inc. 

For instructions on locating and accessing the Rating label, see page 33.

 Rating Label 

3

FP25 LE  040523-36

100003890

Содержание FP25 LE

Страница 1: ...local building or fire officials about restrictions and installation inspection requirements in your area IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER MODEL FP25 LE FP25AR LE SERIAL M...

Страница 2: ...lace Installation 14 Locating your Fireplace 14 Mobile Home Installation notes 14 Crate Removal 14 Dimensions 15 Fireplace Clearances and Dimensions 15 Minimum Framing Dimensions 16 Framing Kit Instal...

Страница 3: ...LTD 2975 ALLENBY RD DUNCAN BC V9L 6V8 MADE IN CANADA FABRIQU AU CANADA U S ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2020 particulate emission standards using Cordwood Tested to ASTM 30...

Страница 4: ...without ample air the smoke cannot burn Smoke free clean burning requires small fuel loads two or three logs at a time or 1 4 to 1 2 of fuel load and leaving the air inlet relatively wide open especi...

Страница 5: ...d cracks before starting another fire Also check combustibles around the chimney and the roof We strongly recommend that your chimney be inspected by professionals who are certified by one of the foll...

Страница 6: ...produce large amounts of smoke and creosote Wet wood also produces very little heat and tends to go out often Wood should be stored under cover away from open flame or heat sources Operation These mat...

Страница 7: ...epeat if flames start to die out Normal Operation WARNING This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this setting...

Страница 8: ...nd prolonged or continual use on a high burn setting Proper Draft Operation with the door open can cause excessive smoke Do not operate this unit in a manner that will cause excessive smoke Draft is t...

Страница 9: ...y Firebrick Visual for cracking Door Gasket sagging placement damage Monthly Brick rail tabs and brick rails Air riser tube in the back of the firebox Back side of airwash chamber Baffle locking pin B...

Страница 10: ...or replace any necessary components to the chimney system Maintain a distance of 48 1 2m to all combustible materials in the room See also Ember Protector on page 23 for the Floor Protection dimension...

Страница 11: ...ING DO NOT SLAM LOADING DOOR OR OTHERWISE IMPACT GLASS WHEN CLOSING DOOR MAKE SURE THAT NO LOGS PROTRUDE TO IMPACT THE GLASS IF THE GLASS GETS CRACKED OR BROKEN IT MUST BE REPLACED BEFORE USING THE FI...

Страница 12: ...e insulation is damaged during removal it should be replaced The baffle should only be removed after the chimney is being cleaned Secondary Air Box Cleaning The Secondary Air Box Cleaning should only...

Страница 13: ...the blower mounting bracket up and pull the top out first and then lift the blower up and out to remove from the bolts If replacing the right side blower then disconnect the two wires leading to the...

Страница 14: ...tor in the chimney performance Therefore the chimney out let position is important when locating the fireplace We recommend whenever possible that the chimney should Penetrate the highest part of the...

Страница 15: ...width of floor protection from side of door opening 8 200mm Minimum depth of non combustible ember protector from the front of the fireplace 16 1 2 420mm Minimum chimney height minimum total chimney h...

Страница 16: ...hase is required for heat management Do Not build a recess shelves or cupboards in the area above this fireplace Do not build anything inside this Minimum chase area Do Not insulate the front portion...

Страница 17: ...bottom stud 2 and then attach the top stud 2 to the center supports 3 Installing the unit into the chase Push the Fireplace into place Casing must be flush with the framing in the front and secure if...

Страница 18: ...the chimney manufacturer s installation requirements Consult your chimney supplier for installation advice 1 After locating the desired location and framing in the fireplace use a plumb bob to line up...

Страница 19: ...pported after the first 20 6 1m in length 1 NOTE Install the vertical chimney section s then the first elbow and turn it in the required direction 2 Install the necessary chimney lengths to achieve th...

Страница 20: ...211 All clearances around the chimney for its entire length must be to code as per the NBC or NFPA 211 The masonry chimney can only be used for this fireplace and no other appliances Make sure the ma...

Страница 21: ...the chase Cover the hole and install a 20GA wire mesh minimum rodent screen and staple nail in place Provide water protection as required by building code Attach 4 102mm venting not supplied between...

Страница 22: ...the wires located in the junction box See Blower Replacement on page 13 All electrical connections should be performed by a certified licensed electrician Consult local codes or in the absence of loc...

Страница 23: ...e front and the other half must extend onto the floor and under the hearth extension ember protection as shown in Figure 17 If the unit is raised up then a 2 x 2 angled piece can be used against the n...

Страница 24: ...uires 6 Listed Approved B vent gas venting This allows reduced clearances in the wall spaces Follow the clearances and applicible installation guidelines in the vent manufacturers instructions this in...

Страница 25: ...44 6 BLOWER FAN BRACKET 9146 7 ELECTRICAL CONNECTION COVER 9144 5 8 REMOTE BLOWER BOX WODC 9141 ITEM DESCRIPTION PART NUMBER 12 5 1 4 7 11 13 8 2 6 3 14 9 10 HEAT DUCT Replacement Parts 9 BLOWER 5024...

Страница 26: ...ngth and number of bends To maximize the performance the length and number of bends should be kept to a minimum A 12 305mm from the CEILING or SIDE WALLS B 36 914mm from the FLOOR A A B A A Listed B V...

Страница 27: ...Place the Backflow Damper into the top of the unit Figure 23 Ensure that the flap in the assembly is free to move Flap should be in the normally closed position with the blower off 4 Attach the Duct A...

Страница 28: ...or ridged gas vent pipe vent pipe is not include with this kit between the blower and the fireplace Fasten in place with screws and seal with aluminium foil tape 7 Connect the wiring as per the direc...

Страница 29: ...22 2 Canadian Electrical Code or in the USA the National Electrical Code ANSI NFPA 70 Latest Edition The Remote Heat Kit blower s electrical rating 120V 60HZ 80 watts For your protection against shock...

Страница 30: ...from the top facing stop and 58 1 47m wide centered on the unit The front casing of the fireplace has a built in facing edge stop DO NOT PLACE ANY CEMENT BOARD OR FINISHING MATERIALS INSIDE THIS EDGE...

Страница 31: ...distance to the underside of the Mantel max 12 deep from the top of the Heat Exchanger Air Deflector 16 406mm Minimum distance to the adjacent wall from the side of the fireplace door 22 560mm Minimu...

Страница 32: ...icks as well as 5 various cut size bricks With the heater in the upright position install firebricks as follows 1 Install the rear firebricks 4 full size two on each side of the baffle tube Then place...

Страница 33: ...ating label plate is located on the left side in the bottom casing support between the side casing and the heat shield Figure 32 It is attached to the heat shield by a stainless steel cable 3 To acces...

Страница 34: ...wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t Burn Overnight 1 Air control is set too high Set control lower 2 Not enough...

Страница 35: ...m your nearest Pacific Energy dealer Contact Pacific Energy for the location of the dealer nearest you 3 12 13 14 4 5 6 7 8 16 10 9 2 11 1 15 NE25 DRBK 3a Parts Diagram ITEM DESCRIPTION PART NUMBER 9...

Страница 36: ...Products LTD Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws For technical support please contact your retailer Web sit...

Отзывы: