Door Glass/Gaskets
• If glass becomes darkened through slow burning or poor wood, it can be cleaned with fireplace glass
cleaner when the fireplace is cold. Never scrape with an object that might scratch the glass. The type and
amount of deposit on the glass is a good indication of the flue pipe and chimney buildup. A light brown
dusty deposit that is easily wiped off usually indicates good combustion and dry, well-seasoned wood and
therefore relatively clean pipes and chimney. On the other hand, a black greasy deposit that is difficult to
remove is a result of wet and green wood and too slow a burning rate. This heavy deposit is building up as
quickly in the chimney.
• DOOR GASKETS - The gasket used by Pacific Energy (7/8”(22mm) medium density fibreglass rope)
requires only light pressure to seal. This will prolong seal life. It is important that the door seal be
maintained in good condition. Periodically inspect seals and replace if necessary.
• DOOR GLASS - Replacement glass can be obtained from your dealer. Use 18” (457mm) x 10-1/4”
(260mm) x 5 mm ceramic glass only.
WARNING: DO NOT SUBSTITUTE GLASS WITH ANY OTHER TYPE MATERIAL OTHER THAN CERAMIC
GLASS
WARNING: DO NOT SLAM LOADING DOOR OR OTHERWISE IMPACT GLASS. WHEN CLOSING DOOR,
MAKE SURE THAT NO LOGS PROTRUDE TO IMPACT THE GLASS. IF THE GLASS GETS CRACKED OR
BROKEN, IT MUST BE REPLACED BEFORE USING THE FIREPLACE.
To remove broken glass,remove the door gasket. Remove the screws that holds the retainer to the door and
remove the retainer, noting position for reassembly. Remove all particles of glass. Be careful as they are very
sharp. Install new glass complete with gasket. Replace retainers, screws and gasket.
CAUTION:
DO NOT OVERTIGHTEN, TIGHTEN SCREWS HAND TIGHT
DO NOT CLEAN GLASS WHEN HOT
DO NOT USE ABRASIVE CLEANERS ON GLASS
Blowers:
It is recomended that the Blowers should be cleaned out at least once a year minimum.
1. The blowers are accessed by removing the Front Trim Panel. Lift up and pull the Front Trim away from the
unit, the blowers are located on each side of the Firebox.
2. Use a vacuum to gently remove dust and debris from the intakes and wheel of the blower.
Baffle:
• Some warping of the baffle is normal(up to 1/4” or .65cm).
• Replace if the baffle has permanent warping greater than this or has cracking or breakage.
• Please contact your Dealer if you experience any of the damage listed above. Continuing to operate your
fireplace with broken parts may accelerate damage to other parts
• and may void your warranty.
11
FP25 LE 040523-36
100003890