Fireplace Dimensions
Clearances to Combustibles
Figure 21: Minimum Distance
From Top Of The Glass To Ceiling
Figure 22: Front and Side Definitions
Front of the appliance is an open side of the combustion chamber covered with the
glass.
Facing the front of the appliance side from left is the left side of the appliance and side
from right is the right side of the appliance.
Minimum Clearance to Combustible Materials
ENCLOSED SIDE WALL
1.75"
ENCLOSED BACK WALL
NCR*
ENCLOSED CEILING
4"
ECLOSED FRONT WALL
24" From top of the glass
EXPOSED SIDE WALL
8" From side of the glass
VENT ENCLOSURE
1"
EXTERIOR SOFIT
16"
*NCR STANDS FOR N O CLEARANCE REQUIRED; YOU MAY USE COMBUSTIBLE CONSTRUCTION
MATERIALS IN DIRECT CONTACT WITH THE APPLIANCE ON THESE SURFACES.
When the appliance is installed directly on carpeting, tile or other combustible material other than wood
flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the
appliance. Specified clearances shall be maintained from the top surface of carpeting, tile, etc.