8
Fig. # 12
Draft Inspection
This appliance must be connected to a venting system with
adequate draft to ensure safe and proper operation.
To inspect vent operation:
A few minutes after the appliance is lit, insert a smoke stick
between the middle and top louver (Fig. #13). If the smoke
is drawn in, the venting system is operating properly. If the
smoke is not drawn into the opening, turn the unit off and
inspect the venting system for blockages or restrictions.
Vent Safety Shutoff System
Installation
This appliance is equipped with a vent safety shutoff system.
The switch assembly is shipped with the burner.
1) Unravel wire, feed through front grommeted hole located
on the firebox support and right hand casing side.
2) Remove the two screws located at the uppermost right
front corner of the appliance.
3) Position the spill switch over the two holes and fasten in
place with the two screws (Fig. #11).
Fig. # 11
Fig. # 13
Smoke Stick
Spill Switch
Rocker Switch
Gas Valve
Thermopile