
23
SPNE 190913-24
Label
DATE OF MANUFACTURE
INSTALLEZ ET UTILISEZ SELON LES INTRUCTIONS D’INSTALLATION ET D’OPÉRATION DU PACIFIC ENERGY. BÂTIMENT
OU POMPIERS LOCAUX DE CONTACT AU SUJET DES CODES, RESTRICTIONS ET D’INSPECTION D’INSTALLATION
DANS VOTRE SECTEUR. INSTALLEZ ET EMPLOYEZ SEULEMENT EN MAÇONNERIE OU CHEMINÉE CONSTRUITE PAR
USINE. NE RELIEZ PAS CETTE UNITÉ À UNE CONDUITE DE CHEMINÉE DE CHEMINÉE SERVANT UN AUTRE APPAREIL.
MATERIEL REQUIS POUR L INSTALLATION:PLEIN REVÊTEMENT DE CONDUITE DE CHEMINÉE CONFORMÉMENT À CAN/
ULC-S635 OR CAN/ULC-S640. COMPOSANTS FACULTATIFS: 3” VENT OFFSET(SPND.3OFFSETA), FAN, ÉLECTRIQUE
115V, 60HZ, 1.6 AMP. ITINÉRAIRE POWERCORD À PARTIR D’UNITÉ. POUR UTILISATION AVEC COMBUSTIBLE AU BOIS
SEULEMENT. N’UTILISEZ PAS LA GRILLE OU N’ÉLEVEZ PAS LE FEU EN BOIS DE FIRE-BUILD DIRECTEMENT SUR
LE FOYER. REMPLACES LA VITRE AVEC UNIQUEMENT DE LA VITRE CÉRAMIQUE. INSPECTEZ ET NETTOYEZ LA
CHEMINÉE FRÉQUEMMENT-DANS CERTAINES CONDITIONS D’UTILISATION, L’HABILLAGE DE CRÉOSOTE PEUT SE
PRODUIRE RAPIDEMENT. OPÉREZ SEULEMENT AVEC LA PORTE D’ALIMENTATION FERMÉE. OUVREZ-VOUS POUR
ALIMENTER LE FEU SEULEMENT.
MADE IN CANADA
F
M
A
M
J
J
A
S
O
N
D
2009
2010
2011
2012
2013
2014
U.S. ENVIRONMENTAL PROTECTION AGENCY
CERTIFIED TO COMPLY WITH JULY 1990
PARTICULATE EMISSION STANDARDS
J
LISTED FACTORY BUILT FIREPLACE ACCESSORY INSERT
CERTIFIED FOR USE IN CANADA AND U.S.A.
TESTED TO / ÉPROUVÉ SELON:
ULCS628-93 / UL1482(2011)
MODEL / MODÈLE: SUPER INSERT SERIES / SÉRIE: E
190913 5050.74.B
SPNE-1
CAUTION
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN
BURNS. SEE NAMEPLATE AND INSTRUCTIONS.
MANUFACTURED BY:
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
INSTALL AND USE ONLY IN ACCORDANCE WITH PACIFIC ENERGY’S INSTALLATION AND OPERATING INSTRUCTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT CODES, RESTRICTIONS AND INSTALLATION INSPECTION IN
YOUR AREA. INSTALL AND USE ONLY IN MASONRY OR FACTORY BUILT FIREPLACE. DO NOT CONNECT THIS UNIT TO
A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
COMPONENTS REQUIRED FOR INSTALLATION : FULL FLUE LINER CONFORMING TO CAN/ULC-S635 OR CAN/ULC-S640.
IN U.S.A. FLUE LINER CONFORMING TO UL-1777 OR DIRECT FLUE CONNECTION ASSEMBLY.
OPTIONAL COMPONENTS: 3" VENT OFFSET(SPND.3OFFSETA), FAN, ELECTRICAL RATING 115V, 60HZ, 1.6 AMP. ROUTE
POWER CORD AWAY FROM UNIT.
FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATE FIRE-BUILD WOOD FIRE DIRECTLY ON
HEARTH. REPLACE GLASS ONLY WITH CERAMIC GLASS. INSPECT AND CLEAN CHIMNEY FREQUENTLY-UNDER CER-
TAIN CONDITIONS OF USE, CREOSOTE BUILDUP MAY OCCUR RAPIDLY.
OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY.
WN#16407 ETL# 4001507
MINIMUM CLEARANCE TO COMBUSTIBLES (MEASURED FROM INSERT BODY)
DÉGAGEMENT MINIMUM AUX COMBUSTIBLES
A)
ADJACENT SIDEWALL/
254 MM / 10 IN
PAROI
LATÉRALE
ADJACENTE
B)
MANTEL
381 MM / 15IN
C)
TOP FACING/
381 MM / 15IN
REVÊTEMENT SUPÉRIEUR
D)
SIDE FACING/
165 MM / 6.5 IN
REVÊTEMENT
LATÉRAL
INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH. COMBUSTIBLE FLOOR BEYOND HEARTH MUST BE PROTECTED BY
NON-COMBUSTIBLE FLOOR MATERIAL EXTENDING IN CANADA: 457 MM/ 18 IN ON THE FIRING SIDE (E) AND 200 MM / 8
IN TO THE OTHER SIDES (F)
IN U.S.A.: 406 MM / 16 IN TO THE FRONT OF (E) AND 200 MM / 8 IN TO THE SIDES OF THE FUEL LOADING DOOR (F)
AU CANADA: LE PLANCHER COMBUSTIBLE DEVANT LE FOYER DOIT ETRE PROTEGE PAR UN MATERIEL A L EPREUVE
DU FEU QUI EXCEDE 457 MM / 18 PO DU CÔTÉ DU CHARGEMENT ET 203 MM / 8 PO SUR LES AUTRES CÔTÉS.
CLEARANCE TO COMBUSTIBLE
CONSTRUCTION
F
ADJACENT SIDE W
A
LL
A
B
D
E
C
F
501
The ceritfi cation label is located on the left side casing of the insert.
CERTIFICATION
LABEL
Содержание DESIGN-E
Страница 21: ...21 SPNE 190913 24 NOTES...
Страница 22: ...22 SPNE 190913 24 NOTES...