background image

14

SPNE 190913-24

Blower

The Super Insert comes equipped with twin variable speed 
circulating air blowers.  The blower system is thermostatically 
controlled for automatic operation, as as well manually with a 
convenient bypass switch.

Blower Operation

Automatic:  To operate the blowers automatically, push the 
rocker switch to the “OFF” or “-” position and set the fan speed 
control to a desired setting.

This will allow the blowers to turn on automatically once the 
Insert has come up to operating temperature.  It will also shut 
the blower off after the fi re has gone out and the appliance 
has cooled to below a useful heat output range.

Manual:  To manually operate the blowers, push the rocker 
switch to the “ON” or “O” position and set the fan speed control 
to a desired setting.  This will bypass the temperature switch 
and allow full control of the blower.

Suggested settings:

 

- Combustion air control setting of “L” (low) position (pushed 
to the far right), operate blower speed control on “Low”.

 

- Combustion air control set at anything above  “L” (low), 
operate blower speed control at desired setting.

Electrical Supply

Circulating air blower electrical rating; 115V, 60 Hz, 1.1 A.  For 
your protection against shock hazard, use only a properly 
grounded outlet that will accept a three-pronged plug.  Do not 
cut or remove the grounding prong.

Consult local codes or, in the absence of local codes, with the 
current CSA C22.1 Canadian Electrical Code and in the USA 
with the National Electrical Code, ANSI/NFPA 70 (latest edition).

Over Firing

Over fi ring can be caused by operating the unit with the door 
open, damage to door gaskets allowing excess air to enter 
the fi rebox, the use of kiln dried lumber, mill ends or paper 
waste and prolonged or continual use on a high burn setting.

More Wood, More Heat

Seasoned wood has approximately 7500 BTU’s per pound.  If 
you put 10 pounds of wood in your stove for an eight hour burn 
the wood will be producing 9375 BTU’s per hour.  (7500 BTU x 
10 lbs / 8 hrs. = 9375 BTU’s per hr.).  If you put 20 lbs of wood 
in your stove for an eight hour burn you will get 18,750 BTU’s 
per hr. (7500 BTU x 20 lbs / 8 hrs. = 18,750 BTU’s per hr.).  
This is only an example and is based on 100% efficiency.  In 
reality, your stove should perform in the 82% efficiency range.

Experience will give you the right settings for proper combus-
tion and efficient burning.  Remember, the air inlet setting is 
affected by variables such as type of wood, outside tempera-
ture, chimney size and weather conditions. With practice, you 
will become profi cient in operating your heater and will obtain 
the performance for which it was designed.

Proper Draft

1)  Draft is the force which moves air from the appliance up 

through the chimney.  The amount of draft in your chimney 
depends on the length of the chimney, local geography, 
nearby obstructions and other factors. 

2)  Too much draft may cause excessive temperatures in the 

appliance.  An uncontrollable burn or a glowing red stove 
part or chimney indicates excessive draft.

3)  Inadequate draft may cause backpuffing into the room and 

plugging of the chimney.  Smoke leaking into the room 
through appliance and chimney connector joints indicates 
inadequate draft.

Ash Removal

Whenever ashes get 3 to 4 inches deep in your fi rebox, and 
when fi re has burned down and cooled, remove excess ashes. 
Leave an ash bed approximately 1 inch deep on the fi rebox 
bottom to help maintain a hot charcoal bed.

Disposal of Ashes

Ashes should be placed in a metal container with a tight fi t-
ting lid.  The closed container of ashes should be placed on 
a non-combustible fl oor or on the ground, well away from all 
combustible materials, pending fi nal disposal.  If the ashes 
are disposed of by burial in soil or otherwise locally dispersed, 
they should be retained in the closed container until all cinders 
have thoroughly cooled.  Other waste should not be placed 
in this container!

L2 (black)

G (green)

L1 (white)

Speed

Control

Blowers

Thermo

Switch

By-pass

Rocker Switch

Electrical Rating : 115 V, 60 Hz, 1.1A

Fig. # 23

Содержание DESIGN-E

Страница 1: ...nsult local building inspector or officials about restrictions and installation inspection requirements in your area Super Insert IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER SAVE THE...

Страница 2: ...ustion Air 12 Operation 13 Wood Selection 13 How to Test Your Wood 13 Lighting the Fire 13 Normal Operation 13 Restarting After Extended or Overnight Burns 13 Over Firing 13 More Wood More Heat 14 Pro...

Страница 3: ...als about restric tions and installation inspection requirements in your area Clearances Masonry or Factory Built Fireplace Theminimumrequiredclearancestosurroundingcombustible materialswheninstalledi...

Страница 4: ...ket Baffle Top heat shield and mounting bolt Baffle Gasket Brick Rails Manifold Some warping of the baffle is normal up to 1 4 or 65cm Replace if the baffle has permanent warping greater than this or...

Страница 5: ...t embers by non combustible material extending 16 USA and 18 CANADA to the firing side and 8 to other sides of the unit Consult CAN CSA B365 Installation Code for Solid Fuel Burning appliances and equ...

Страница 6: ...6 SPNE 190913 24 43 3 8 6 1 2 29 3 16 23 3 4 21 1 2 21 1 8 36 8 3 4 20 3 4 18 28 1 8 9 1 2 10 21 Dimensions...

Страница 7: ...een in use for some time The existing fireplace damper is to be locked open or removed completely WARNING Do not remove bricks or mortar from your existing fireplace Exception Masonry or steel includi...

Страница 8: ...pe Note A clean out door may be required under local codes when a direct flue connection is used Consult local codes 3 Push the Insert into position inside the fireplace and at tach the connector pipe...

Страница 9: ...and thermal snap switch Take note of where the wires are routed and secured They must be positioned correctly to avoid damage 3 Loosen the two bolts that secure the ash lip to the firebox carefully l...

Страница 10: ...ch Fig 16 refit ash lip sides and top Ensure that the power cable is correctly routed through the surround and it is not touching the firebox side Wire placement is important to prevent damage to wire...

Страница 11: ...on page 9 and then remove the decorative top by loosening the two wing bolts underneath and sliding it out of the brackets Fig 18 4 Slide the assembled surround from the top down and engage in slots...

Страница 12: ...as described in the installation section When the installation is complete do not seal surround to fireplace This will allow enough combustion air to enter the fireplace cavity and the Insert Removal...

Страница 13: ...ion after a good coal base exists and wood has charred Normal Operation 1 Set air control to desired setting If smoke pours down across the glass waterfall effect this indicates you have shut the cont...

Страница 14: ...ood will be producing 9375 BTU s per hour 7500 BTU x 10 lbs 8 hrs 9375 BTU s per hr If you put 20 lbs of wood in your stove for an eight hour burn you will get 18 750 BTU s per hr 7500 BTU x 20 lbs 8...

Страница 15: ...ning requires small fuel loads two or three logs at a time or 1 4 to 1 2 of a fuel load and leaving the air inlet relatively wide open especially during the first 10 to 30 minutes after each loading w...

Страница 16: ...it must be replaced before using the stove Re placement glass can be obtained from your Dealer The size required is 8 13 16 x 15 1 4 x 5 mm Ceramic glass must be used Do not substitute with any other...

Страница 17: ...Handle Assembly WODC 4147C 13 Flame Shield WINS 4513 14 Replacement Baffle Kit SSER DBAKIT 15 Brick Rail Set SSER RAILSET 16 Firebrick Set BRIC SSERA 17 Boost Manifold 4105 18 O A Cover 4557 19 Air S...

Страница 18: ...a heat storage and the thermalinsulationkeepsthecombustionzonehot Active flamingtakesplaceduringthefirstpartoftheburn During this stage heat is stored in the mass of the unit and is later released sl...

Страница 19: ...Door Gasket leakage Replace gasket Check latch Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Area too large 4 Poor insulation or open concrete Won t Burn Overnight...

Страница 20: ...lation This package contains 18 full size firebricks as well as 1 cut size brick With the heater in the upright position install firebricks as follows Place firebricks on the bottom of the heater firs...

Страница 21: ...21 SPNE 190913 24 NOTES...

Страница 22: ...22 SPNE 190913 24 NOTES...

Страница 23: ...V9L 6V8 INSTALL AND USE ONLY IN ACCORDANCE WITH PACIFIC ENERGY S INSTALLATION AND OPERATING INSTRUCTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT CODES RESTRICTIONS AND INSTALLATION INSPECTION...

Страница 24: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD www pacificenergy net Phone 1 250 748 1184 2975 Allenby Rd Duncan B C V9L 6V8 Printed in Canada...

Отзывы: