23
INSTALLER
INFORMATION
Gas Pressure Testing Procedure
Note: To test the gas pressure, turn off the gas supply to the appliance before loosening
test point screws.
Verify gas pressures with the fireplace lit and at the highest setting.
1. Remove door (Fig. 28) and locate the valve as seen in Figure 24.
2. Locate the inlet and outlet test points on the valve which can be seen in Figure 25. After
locating test ports loosen the screws within the ports using a flat-tip screwdriver.
3. Attach pressure gauge to the test ports
4. Turn gas supply back on and test pressures.
5. After testing is finished turn off gas supply, remove the pressure gauges and retighten the
screws in the test points.
Pilot Adjustment
The pilot flame level can be adjusted by
turning the adjustment screw, using a flat-
tip screwdriver, seen on the valve in
Figure 25.
Figure 24: Valve Location
Figure 25: Valve
Battery Box
Содержание BROADWAY
Страница 14: ...14 OWNER S INFORMATION Lighting Instructions...
Страница 33: ...33 INSTALLER INFORMATION...
Страница 34: ...34 INSTALLER INFORMATION...
Страница 35: ...35 INSTALLER INFORMATION...