Important Note for the Commonwealth of Massachusetts: 

 

From Massachusetts Rules and Regulations 248 CMR 5.08: 

 

(a) 

For all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, 

including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the 

area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied. 

 

1. 

INSTALLATION OF CARBON MONOXIDE DETECTORS.  At the time of installation of the side wall horizontal vented gas fuelled equipment, the 

installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the 

gas equipment is to be installed, in addition, the installing plumber or gas fitter shall observe that a battery operated or hard-wired carbon monoxide detector with 

an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fuelled equipment.  It shall be the 

responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard-wired carbon monoxide detectors.   

 

a. 

In the event that the side wall horizontally vented gas fuelled equipment is installed in a crawl space or an attic, the hard-wired carbon monoxide detector 

with alarm and battery back-up may be installed on the next adjacent floor level. 

 

b. 

In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall have a period of thirty (30) days 

to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall 

be installed. 

 

2. 

APPROVED CARBON MONOXIDE DETECTORS.  Each carbon monoxide detector as required in accordance with the above provisions shall comply 

with NFPA 720 and be ANSI/UL 2034 listed as IAS certified. 

 

3. 

SIGNAGE.  A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above 

grade directly in line with the exhaust vent terminal for the horizontally vented gas fuelled heating appliance or equipment.  The sign shall read, in print size no less 

than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW.  KEEP CLEAR OF ALL OBSTRUCTIONS”. 

 

4. 

INSPECTION.  The state or local gas inspector of the side wall horizontally vented gas fuelled equipment shall not approve the installation unless, upon 

inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.089(2)(a) 1 through 4. 

 

(b) 

EXEMPTIONS.  The following equipment is exempt from 248 CMR 5.089(2)(a) 1 through 4. 

1. 

The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and  

2. 

Product Approved side wall horizontal vented gas fuelled equipment installed in a room or structure separate from the dwelling, building or structure used in 

whole or in part for residential purposes. 

 

(c) 

MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM PROVIDED.  When the manufacturer of Product Approved side wall 

horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the 

manufacturer for installation of the equipment and the venting system shall include:  

1. 

Detailed instructions for the installation of the venting system design or the venting system components; and 

2. 

A complete parts list for the venting system design or venting system. 

 

(d) 

MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED.  When the manufacturer of a Product Approved 

side wall horizontally vented gas fuelled equipment does not provide the parts for venting the fuel gases, but identifies “special venting systems”, the following 

requirements shall be satisfied by the manufacturer. 

1. 

The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and 

2. 

The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation 

instructions. 

 

(e)) 

A copy of all installation instructions for all Product Approved side wall horizontally vented gas fuelled equipment, all venting instructions, all parts 

lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

 

Содержание BROADWAY

Страница 1: ...as supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified ins...

Страница 2: ...rectly in line with the exhaust vent terminal for the horizontally vented gas fuelled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT D...

Страница 3: ...g 20 Plumbing and Electrical 21 Gas Supply 22 Gas Pressure Check Output Efficiency 22 Gas Pressure Testing Procedure 23 Pilot Adjustment 23 Propane Conversion 24 Door Installation Removal 25 Fan Insta...

Страница 4: ...supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Do not use the...

Страница 5: ...ss is provided with the Surround Kit component and shall be installed If the barrier becomes damaged the barrier shall be replaced with the manufacturers barrier for this appliance Any grill panel or...

Страница 6: ...is manual and pay close attention to all Safety Warnings The manual contains important information on the unit s safe operation and maintenance When lit for the first time the fireplace will emit a sl...

Страница 7: ...he gas valve and stepper motor Transmitter Remote Control with LCD Display The Proflame Transmitter uses a streamline design with a simple button layout and informative LCD display Fig 1 The transmitt...

Страница 8: ...y one transmitter is used then press again the button program to exit the synchronization phase The system is now initialized IFC Module The Proflame 2 Integrated Fireplace Control IFC board is a devi...

Страница 9: ...ommand Turn off the Appliance With the system ON press the ON OFF Key on the Transmitter The Transmitter LCD display will only show the room temperature At the same time the IFC will be commanded to t...

Страница 10: ...the transmitter will change to show that the room thermostat is ON and the set temperature is now displayed Fig 7 To adjust the set point press the up or down arrow keys until the desired set point t...

Страница 11: ...se the Up Down Arrow Keys Fig 1 to turn on off or adjust the fan speed fig 10 A single beep will confirm reception of the command Continuous Pilot Intermittent Pilot CPI IPI selection With the system...

Страница 12: ...etc When the IFC batteries are low a double beep will be emitted from the IFC board when it receives a command from the transmitter This is an alert for a low battery condition for the IFC board When...

Страница 13: ...emblies for soot buildup If excessive buildup of soot is present have a qualified service person inspect and adjust unit for proper combustion Clean burners with a brush or vacuum cleaner paying close...

Страница 14: ...14 OWNER S INFORMATION Lighting Instructions...

Страница 15: ...15 INSTALLER INFORMATION Fireplace Dimensions Broadway Brentwood Figure 13 Brentwood Dimensions Figure 12 Broadway Dimensions 14 3 4...

Страница 16: ...ny modifications that will compromise the integrity of the existing fireplace are not allowed To make way for the insert s venting the fireplace flue dampener may be blocked open or removed Refractory...

Страница 17: ...16 MANTEL CLEARANCE Broadway Brentwood A 20 1 2 32 B 16 32 C 11 32 MANTEL DEPTH D 12 E 9 F 6 Clearances to Combustibles 8 Figure 15 Mantel Clearances Figure 16 Sidewall Clearances Minimum hearth dept...

Страница 18: ...using supplied screws and mounting holes located along the inner edge of the base 2 Install the safety screen by aligning it with surround base and then pressing it into place Note Install screen insu...

Страница 19: ...19 INSTALLER INFORMATION GBWY SMBKA GBWY SMBKOSA GBNT STBKA GBNT STSSA GBNT STBKOSA GBNT STSSOSA GBNT SMBKA GBNT SMBKOSA GBWY STBKA GBWY STSSA GBWY STBKOSA GBWY STSSOSA Figure 19 Surround Dimensions...

Страница 20: ...er pipe to the outlet side of vent terminal Seal and secure with sealant and screws provided 3 Insert both flex liners from top of the chimney down through the damper opening 4 Before attaching vent t...

Страница 21: ...ect the gas supply line to the 1 2 flex tubing that extends out of the unit as seen in Figure 23 Please see the gas supply section of the manual for requirements of the gas supply Next plug the power...

Страница 22: ...sibility of any loose scale or dirt within the gas supply line from entering the control valve It is essential that a union or flanged connection be installed just upstream of the valve and inside the...

Страница 23: ...n the valve which can be seen in Figure 25 After locating test ports loosen the screws within the ports using a flat tip screwdriver 3 Attach pressure gauge to the test ports 4 Turn gas supply back on...

Страница 24: ...r tray as seen in figure 26 The orifice can be removed using a socket Before installing the new orifice Loctite 567 Thread Sealant needs to be applied to the threads of the new orifice to ensure a pro...

Страница 25: ...tion 1 Connect wiring to fan and insert into the fireplace through the back of the unit 2 Insert all screws into the fan access panel to attach the fan to the unit 3 Push the gas insert fireplace back...

Страница 26: ...seen in Figure 33 Removal 1 Remove the baffle by removing screws securing the front edge of the baffle seen in Figure 33 After removing the two screws you can slide the baffle out of the fireplace 2...

Страница 27: ...gure 34 Air Deflector Burner Tray Installation Removal Installation Place the burner tray in the fireplace and secure with 4 screws using a screwdriver as seen in figure 35 Removal Remove the 4 screws...

Страница 28: ...ks in front of the front log to hide the burner as seen in Figure 42 Note Do Not Block Burner Ports with Embers Removal 1 Remove embers from fireplace 2 Lift the decorative log off of the front log an...

Страница 29: ...ecure with 4 screws using a screwdriver as seen in figure 45 Removal Remove the 4 screws seen in figure 45 using a screwdriver and remove the burner tray Glass Installation To install the glass evenly...

Страница 30: ...NEL PORC Copper BDEM PPNCUA Burner Set required BDWY ESTM DESIGNER LOG BNR BDEM NG01A BDWY ESTM GLASS BURNER BDEM NG03A Optional Components BDWY ESTM BLOWER BDEM BLOWA Metro Rock Set Black GASC METROB...

Страница 31: ...31 INSTALLER INFORMATION Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing...

Страница 32: ...________________ __________________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 33: ...33 INSTALLER INFORMATION...

Страница 34: ...34 INSTALLER INFORMATION...

Страница 35: ...35 INSTALLER INFORMATION...

Страница 36: ...36 INSTALLER INFORMATION Technical support 1 250 748 1184 Web site www pacificenergy net 2975 Allenby Rd Duncan BC V9l 6V8...

Отзывы: