22"
559mm
12"
305mm
18"
457mm
30"
762mm
25"
635mm
11"
279mm
11"
279mm
18"
457mm
4"
102mm
4"
102mm
16"
406mm
16"
406mm
10"
254mm
20"
508mm
15"
381mm
28"
711mm
26"
660mm
14"
356mm
5"
127mm
Fig #2
SINGLE WALL
CONNECTOR
DOUBLE WALL
CONNECTOR
ALCOVE: Min. Height 7 feet(2.1m)
Max. Depth 4 feet(1.2m)
Fig #2a
Minimum Clearances to Combustibles – Residential
9”
229mm
14”
356mm
17.75”
451mm
28.75”
756mm
20.25”
514mm
6”
152mm
6”
152mm
16.25”
413mm
7.5”
191mm
13”
330mm
27.75”
705mm
18.75”
476mm
30.75”
781mm
19.25”
489mm
5”
127mm
5”
127mm
Do not connect this unit
to a chimney flue serving
another appliance.
190617-24 AL6B
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
7
Clearances – Residential
1. This heater may be installed using a single-wall connector (smoke pipe) or listed double-
wall connector (see Mobile Home installation).
2. Clearances to combustible surfaces and materials using single-wall connector are shown
in Figure #2.
Clearances may be reduced with various heat insulating materials. Consult local, National
fire codes and authorities for approval.
3. Alternately, for close clearances, use a listed double-wall connector.
See Figure #2a.
Installation – Residential
Warning:
Under no circumstances is this heater to be installed in a makeshift or "temporary" manner.
It may be fired only after the stove is installed properly.
• DO NOT ATTEMPT TO CONNECT THIS HEATER TO ANY AIR DISTRIBUTION
DUCT.
• We recommend that our woodburning hearth products be installed and serviced by
professionals who are certified in the U.S. by the National Fireplace Institute
®
(NFI) as
NFI woodburning Specialists or who are certified in Canada by Wood Energy
Technical Training (WETT).
• Outside combustion air or fresh air into the room may be required in your area, consult
local building codes (see Combustion Air section).
BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE LISTED TO: IN CANADA
- ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY, IN USA
- UL-103 HT LISTED CONNECTOR AND CHIMNEY