16
If battery connections are reversed it will blow-out the
converter fuse(s) so be sure to check battery
connections. Power converters produce a lot of heat
and generally have a fan that goes on during heavy use
of electrical equipment in the trailer.
Electronic over current shut-down.
The
converters have built-in electronic over current
protection to prevent damage due to short circuits or
other overload conditions. This system operates much
faster than fuses and will automatically reset itself,
when the overload condition is removed. Please note
there is a possibility that the customer's battery is com-
pletely discharged when customer tries to operate
lights and other 12 VDC appliances before the battery
has taken on sufficient charge. The converter may shut
down due to overload. Have the customer turn off all
12 VDC lights and appliances until the battery has
taken on a charge for an hour or two. Only then should
customer try to operate his 12 volt system.
Automatic over temperature shut-down.
In the
unlikely event of a fan failure or insufficient venti-
lation in the power converter compartment, these
converters will automatically shut down. This safety
feature is self resetting and will automatically turn
the converter back on when the temperature returns
to a safe level. If the power converter seems to be
cycling on and off suspect a bad fan or insufficient
converter ventilation causing an over temperature
shutdown.