background image

 

1. 

INPUT POWER

 12VAC 40VA SUPPLIED (voltage measurement must be  (12.5-14.0 VAC)  

OR 12VDC 2A adjustable power supply (voltage measurement must be 13.5-14.0 VDC)  
 

2. 

12 VDC 4Ahr BATTERY BACK-UP (OPTIONAL) 

WARNING: THIS IS NOT INPUT POWER

 

 

3. 

DOOR 2 DRY CONTACT RELAY, MUST USE SEPARATE POWER FOR DOOR STRIKE  
 

4. 

DOOR 1 DRY CONTACT RELAY, MUST USE SEPARATE POWER FOR DOOR STRIKE  
 

5. 

TELEPHONE OUT LOOP TO NEXT QC SYSTEM, IF TELEPHONE LINE IS SHARED 
 

6. 

 TELEPHONE INPUT ANALO

G DIAL TONE “ONLY”  

 

7. 

AUX 1 AND AUX 2 FOR EXIT SWITCH, LOOP DETECTOR OR ANY INPUT DEVICE WITH DRY CONTACT OUTPUT.  
 

8. 

DOORS1 AND DOORS 2 SENSOR. 

WARNING: THESE ARE NOT DOOR CONTACTS

 

 

9. 

RS-485 PORT, CONNECT TO SLAVE UNITS (USCR, UCRM, USKP AND USKPR) UP TO 8 UNITS  
 

10.  26-WIEGAND INPUT. PROPRIETARY CARD READER IS BUILT-IN ON THE QC SERIES. DISCONNECT THE BUILT-IN READER IF YOU 

ARE USING YOUR OWN CARD READER.  
 

11. 

FACTORY USE “ONLY” TO POWER THE QWCM IP MODULE AND FAN. 

WARNING: 

“DO NOT USE THE +12VDC POWER TO POWER 

ANY OTHER DEVICES”. 
 

12.  AATA2 INPUT POWER 5VDC 3.0A (SUPPLIED) 

 

13.  AATA2 INTERNET CONNECT TO ROUTER OR SWITCH 

 

14.  AATA2 LAN CONNECT TO QWCM (#17) 

 

15.  AATA2 PHONE 1 ANALOG DIAL TONE.  

 

16.  QWCM POWER AND COMMUNICATION CONNECT TO (#11 12VDC POWER) AND (#18 RS-232). DO NOT UPLUG THIS CONNECTOR 

WITH POWER ON FACTORY PREWIRED 
 

17.  QWCM ETHERNET PORT CONECT TO ROUTER OR SWITCH. 

DO NOT CONNECT TO AATA2 NO. 14 

 

18.  RS-232 CONNECT TO (#16 ON QWCM) FACTORY PREWIRED

 

 

Technical Support is available  
Monday-Friday 7:00 am-4:00 pm PST at 1-888-678-7224 
Technical Info and complete manual are available online 
www.pach-co.com

 

 

 

AATA2 ACTIVATION  

www.ooma.com/activate

 

Nominal monthly fees and taxes required 
based on zip code.

 

TURN OFF THE SYSTEM’S POWER 
BEFORE CONNECTING OR 
DISCONNECTING ANY DEVICES 