1. 

INPUT POWER

 12VAC 40VA SUPPLIED (voltage measurement must be 12.5-14.0 VAC) OR 12VDC 2A adjustable 

power supply (voltage measurement must be 13.5-14.0 VDC)  
 

2.  12 VDC 4Ahr BATTERY BACK-UP (OPTIONAL) 

WARNING:

 THIS IS NOT INPUT POWER 

 

3.  DOOR 2 DRY CONTACT RELAY, MUST USE SEPARATE POWER FOR DOOR STRIKE  

 

4.  DOOR 1 DRY CONTACT RELAY, MUST USE SEPARATE POWER FOR DOOR STRIKE  

 

5.  TELEPHONE OUT LOOP TO NEXT QC SYSTEM, IF TELEPHONE LINE IS SHARED 

 

6.   TELEPHONE INPUT ANALOG DIAL TONE “ONLY” (from AAT2, SCWT or telephone company analog dial tone) 

 

7.  AUX 1 AND AUX 2 FOR EXIT SWITCH, LOOP DETECTOR OR ANY INPUT DEVICE WITH DRY CONTACT OUTPUT AND 

POSTAL LOCK.  
 

8.  DOORS1 AND DOORS 2 SENSOR. 

WARNING:

 THESE ARE NOT DOOR CONTACTS 

 

9.  RS-485 PORT, CONNECT TO SLAVE UNITS (USCR, UCRM, USKP AND USKPR) UP TO 8 UNITS  

 

10.  26-WIEGAND INPUT PORT 

 

11.  FACTORY USE “ONLY”. WARNING: “DO NOT USE THE +12VDC POWER TO POWER ANY OTHER DEVICES”. THIS IS 

AN OUTPUT VOLTAGE. 

 

 

Technical Support is available  
Monday-Friday 7:00 am-4:00 pm PST at 1-888-678-7224 
Technical Info and complete manual are available online 
www.pach-co.com

 

 

 