Step 5 

G. 

Connect to Telephone Ground Block or Earth Ground using 16-gauge stranded wire. 
 

Step 6 

DOOR STRIKE. 

Form C Dry Contact (120 VAC 10A/ 24 VDC 10A/ 250 VAC 7A) Normally Open (N.O) and Normally Closed (N.C).   
Connect to Normally Open (N.O) and COM if normally open door strike is used. Door is closed if the strike is not energized and open if 
energized. 
Connect to Normally Closed (N.C) and COM if normally closed door strike is used. Door is closed if the strike is energized and open if 
not energized. 
 

• 

18-gauge 2-conductors stranded is recommended. 

 

Step 7 

AUXIN. 

Connect Push Button Switch, Panic Bar, Card Reader, Buzzer, and Postal Lock using minimum 22-gauge wires. 
 

Step 8 

POWER. 

ONLY use a Class 2 transformer rated 12 VAC 20VA (supplied) or 13.5 VDC 20 VA to power the AeGIS 4000. Optional 12 VDC 4Ahr 
battery back up with built-in charger can be installed as shown in figure 2.0. 
 Warning: Do not use 12 VAC 20VA (supplied), if battery back up is used, to do so may damage the system or cause injury. 
 

 

 

 

 
 
 
 

 

 

 

 

 

            Figure 2.0 

 

Programming 

 

Reference Keys 

Description

 

 

Exit Programming Mode or hang-up the call

 

To accept program

 

 and # 

To reset the master code to factory default (0000). Turn the power off then press and hold 

 and #, while 

you are holding both keys, turn the power on; you will hear 

“Two Short Beeps” then “Three Short 

Beeps”.

 

To delete or to hold call and switch in call waiting.

 

 

Logon to programming mode before selecting the function codes on the table: press 0 and # simultaneously and 
release, then enter the Master Code. You will hear 

“One Short Beep” 

if the master code is valid, otherwise repeat this 

process again. Default Master Code is 0000. For more detail see the Owners Manual. 

 

Function Codes 

Description 

00 

Change Unit Master Code, default is 0000 

01-50 

Individual Access Code Index Number 01-50. Access code must be in 
 4-digit format. 

60 

Delete Individual Access Code Index Number 1-10 

61 

Delete Individual Access Code Index Number 11-20 

62 

Delete Individual Access Code Index Number 21-30 

63 

Delete Individual Access Code Index Number 31-40 

64 

Delete Individual Access Code Index Number 41-50 

65 

Delete All Individual Access Codes on index Number 01-50 

70 

Non-indexed Call Forwarding, automatically forward the call to the phone number programmed. No need to 
enable. 

71 

Add or Delete Indexed Call Forwarding Phone # 1. Automatic Call Forwarding is enabled as soon as the 
phone number is programmed on Index 71. Up to 11-digit 

72 

Add or Delete Indexed Call Forwarding Phone # 2, up to 11-digit. 

73 

Add or Delete Indexed Call Forwarding Phone # 3, up to 11-digit. 

74 

Add or Delete Indexed Call Forwarding Phone # 4, up to 11-digit. 

75 

Add or Delete Indexed Call Forwarding Phone # 5, up to 11-digit. 

76 

Delete All Call Forwarding Phone Number. 

87 

Enable or Disable Automatic Call Forwarding. 0=disable 1= enable. Default setting is enabled. 

88 

Select Automatic Call Forwarding Index Number. Index number is 71, 72,73, 74 and 75. Index 71 is 
selected automatically if the phone number is programmed. 

89 

Set Automatic Call Forwarding Time. Automatic call forwarding time is 15-90 seconds. The call forwarding 
time selected must be shorter than the Talk Time (Function Code 91). Default setting 15 seconds. 