21
Operation
Temperature Setback
To preserve tip life and save energy, the ST 115 system can be programmed to
automatically set back its Tip Temperature to 177°C (350°F) after a selected period of
handpiece inactivity (adjustable 10-90 minutes in Set-Up Mode). As received from
the factory, this feature is enabled. Refer to the “Set-Up Mode” section of this
manual to disable or adjust the time-out period of this feature. The operator can also
force the system into Temperature Setback.
Activation
There are two ways in which the system will activate the Temperature Setback feature.
1. AUTOMATIC ACTIVATION - The system memory can be programmed
so that the system will automatically activate Temperature Setback after a
selected period (10-90 minutes) of handpiece inactivity. See the “Set-Up
Mode” section for details on programming this feature.
2. MANUAL ACTIVATION - The operator can manually force the system to
place the system in Temperature Setback by performing the following
procedure.
a) Press and hold the Scroll Down (
▼
) Key.
b) Press the Scroll Up (
▲
) Key.
c) Release both keys.
Operation
Temperature Setback is indicated by the following.
1. The LED display will be flashing.
2. The Operating Temperature will stabilize at 177°C (350°F).