6. Press and release the Tip Temperature Set  

Key. The Digital Readout will display "S-X" (X = 1 -
9). Either the °F or °C will be on. This is the default 
readout (e.g., if the °C LED is on the Digital 
Readout will display temperature readings in °C).

 

°F or °C READOUT  DEFAULT

 

7. Press and release the °F/°C Key to change the 
default. Each subsequent press and release of the 
key will change the default 

AUTOMATIC SETBACK

 

8. As received from the factory, the

temperature will read "S - -" meaning that 
Automatic Setback is turned off. A readout of 1 
thru 9 on the right side of the Digital 
Readout indicates time toAutomatic Setback 
in increments of 10 minutes. For example, "S-3" 
would indicate a timeout of 30 minutes. 
To change the Automatic Setback 
feature, press the Scroll Up Key to 

increase the timeout and/or enable the feature.     
Press the Scroll Down Key to decrease the 
timeout. 

9. Press the Tip Temperature Set Key to store the   

°F/°C default and Automatic Setback value in 
system memory. The Digital Readout will revert to 
display "CAL" and only the Channel 1 LED will remain 
lit

Содержание MBT 220

Страница 1: ...or alter feature status and defaults stored in the system 4 Recalibrate the system for accuracy PROCEDURE KEYLOCK OPTION KEYLOCK 1 An optional KeyLock feature is available from PACE which prevents una...

Страница 2: ...ld the Tip Temperature Set and Scroll Down Keys 4 Place POWER Switch in the ON I Position All of the system LEDs will light The Temperature Display will read 888 and change to read 1 X 5 Release the T...

Страница 3: ...efault AUTOMATIC SETBACK 8 As received from the factory the temperature will read S meaning that Automatic Setback is turned off A readout of 1 thru 9 on the right side of the Digital Readout indicate...

Страница 4: ...are necessary 11 The Channel 1 LED is now lit signifying that Channel 1 is ready for calibration Perform steps 12 through 21 to calibrate As channels change repeat these steps for each channel NOTE Al...

Страница 5: ...oll Up Key or decrease Scroll Down Key the Lower Temperature Limit value 14 Press and release the Tip Temperature Set Key to store the display value into memory 15 The Digital Readout now displays H X...

Страница 6: ...ou do not wish to recalibrate for readout accuracy press the Tip Temperature Offset Key and perform steps 12 through 17 After all channels have been calibrated you may exit the Calibration Mode by pre...

Страница 7: ...microprocessor controlled circuitry is recalibrating another aspect of the system circuitry CAL will now be displayed indicating that calibration of this channel is complete 22 Press and release the T...

Страница 8: ...ghts Reserved Printed in the USA www paceworldwide com TEMPERATURE DISPLAY MESSAGE CODES Listed below are message codes and a description of each which may be displayed on the system power source digi...

Страница 9: ...MAKES NO OTHER WARRANTY EXPRESS OR IMPLIED AND MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Seller will at its option repair or replace any defective products at its facil...