background image

24

ITEM

NO.

DESCRIPTION

PACE PART NUMBER

MBT 101A

MBT 101AJ

MBT 101AE

1

SX-70 Sodr-X-Tractor Handpiece

6010-0077

6010-0077

2

Operation & Maintenance Manual

5050-0381

5050-0381

3

Tubing, Silicone, Translucent, 54" Length

1342-0001-13

1342-0001-13

4

VisiFilter

1309-0028

1309-0028

VisiFilter Replacement Elements (optional item) 1309-0027-P50

1309-0027-P50

5

Bristle Brush, Glass Chamber Cleaning

1127-0002

1127-0002

6

Power Cord

1332-0094

1332-0093

7

Tubing, Clear PVC, 1" Length (Qty. 2)

1325-0003-07

1325-0003-07

8

Wire Brush, 3/16" Dia.

1127-0014

1127-0014

9

Wire Brush, 1/8" Dia.

1127-0006

1127-0006

10

AdapTip Kit (1/8" Tip to 3/16" Shank)

1360-0083-P1

1360-0083-P1

11

Tip Cleaning Kit

6993-0151

6993-0151

12

SX Tip & Tool Stand

6019-0044

6019-0044

13

Tip & Temp. Selection System Charts (booklet)

5050-0251

5050-0251

REPLACEMENT PARTS

Table V.  MBT 101A, MBT 101AJ, MBT 101AE Accessory Tray

ACCESSORY TRAY, MBT 101A/J/E

Listed below are items included in MBT 101A, MBT 101AJ and MBT 101AE System Accessory Trays.

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание MBT 101A

Страница 1: ...excess underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of their respe...

Страница 2: ...MBT 201A MBT 101A SYSTEMS MAINTENANCE MANUAL OPERATION Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 3: ...m quickly perform the Set Up and Quick Start Basic Operation procedures detailed on pages 12 17 of this manual When performing other operations which require use of large or specialized tips PACE recommends that the user read and fully understand the Operation portion of this manual in order to utilize the features of this system Artisan Technology Group Quality Instrumentation Guaranteed 888 88 S...

Страница 4: ...eez SwaPlater ThermoBand Thermo Drive ThermoJet ThermoPart ThermoPik ThermoTweez Tip Evac VisiFilter The following are trademarks and or servicemarks of PACE Incorporated Laurel Maryland U S A and may only be used to identify genuine PACE products or services Auto Off Cubby Vac Datastore Dust Evac EKO Lab Evac PaceLink PaceNet Pik Paste Prep Set Pulse Plate Spa Kleen ThermoBond TweezPik Uni Frame ...

Страница 5: ...Replacement Parts 22 Power Source 22 Accessory Tray MBT 201A J E 23 Accessory Tray MBT 101A J E 24 Accessory Kit MBT 201A J E 25 Accessory Kit MBT 101A J E 26 Manual Improvement Comment Form 27 TABLE PAGE Table I Heater Assembly Checkout Procedures 20 Table II Power Source Corrective Maintenance 21 Table III Power Source Replacement Parts 22 Table IV MBT 201A J E Accessory Tray 23 Table V MBT 101A...

Страница 6: ...ramatically increasing tip life Virtually all of today s specialized handpieces with large SMD tips suffer from a problem in which the actual tip temperature that the work sees can be more than 100 F cooler than the Set Tip Temperature on the Variable Temperature Control MBT 201A 101A systems feature PACE s unique Tip Temperature Selection System which allows the user to set the true temperature d...

Страница 7: ...0 Sodr X Tractor SX SP Tip Tool Stands Tip Temperature Selection System Charts and Accessory Kit MBT 201AE SYSTEM Consists of PPS 80AE 230 VAC 50 Hz Version Power Source SP 2A Sodr Pen Soldering Iron SX 70 Sodr X Tractor SX SP Tip Tool Stands Tip Temperature Selection System Charts and Accessory Kit PETS 5A 5AE SYSTEMS PACE Educational Systems containing everything required for step by step traini...

Страница 8: ...AJ System Version operates on 90 115 VAC 50 60 Hz 138 Watts 1 4 Amp typical 184 Watts 1 8 Amp maximum PPS 80AE MBT 201AE System Version operates on 196 264 VAC 50 Hz 138 Watts 0 6 Amp typical 199 Watts 0 9 Amp maximum VACUUM AND AIR Measurements at front panel AUTO SNAP VAC and Controllable PRESSURE Ports of power source Vacuum Rise Time Evacuates 33 cc 2 cubic inch volume to 25 cm Hg 10 in Hg in ...

Страница 9: ...ge 232 C to 482 C 450 F to 900 F nominal Accuracy 5 of control setting Tip Temperature Stability 1 1 C 2 F at idle from Set Tip Temperature NOTE True minimum and maximum Operating Tip Temperatures may vary depending on handpiece tip selection EOS ESD Tip To Ground Resistance Less than 2 ohms AC Leakage Less then 2 millivolts RMS from 50Hz to 500Hz min Artisan Technology Group Quality Instrumentati...

Страница 10: ...eaning and preparation The slim line pencil grip design and finger actuated vacuum switch allow easy use and manipulation in tight places TT 65 ThermoTweez Handpiece Provides safe one handed reflow and removal of PLCCs LCCCs chip components and other surface mount devices Its high thermal capacity and targeted heat quickly removes large SMDs without damage to the board or adjacent components even ...

Страница 11: ...rked on front panel of power source These include other MBT systems MBT 101A MBT 201A and higher and all ST series systems PRODUCT APPLICATION These products are very versatile and may be used to satisfy a variety of application requirements If you require assistance in the use of this product for your particular application contact your local authorized PACE distributor or call PACE Applications ...

Страница 12: ...AUTO SNAP VAC PORT Quick connect fitting which provides quick rise vacuum for Sodr X Tractor or ThermoPik handpieces Vacuum is present when handpiece finger switch or optional foot pedal is actuated Vacuum continues a minimum of 1 2 seconds after switch or foot pedal actuation 9 CONTROLLABLE PRESSURE PORT Quick connect fitting with adjustable valve which provides variable air flow for the Mini The...

Страница 13: ...9 GENERAL INFORMATION Figure 1 Parts Identification Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 14: ...t in severe personnel injury or death Danger is not used for property damage unless personal injury risk is present The purpose of this SAFETY section is to inform users of the heading guidelines used in this manual to indicate special Notes Cautions Warnings or Dangers Also included are recommended precautions which must be observed when operating or servicing this product HEADING GUIDELINES PACE...

Страница 15: ...ass Never remove this chamber using pliers Breakage of the chamber may result Always remove using the procedures recommended by PACE in the associated handpiece manual 2 The front end heater end of the glass solder collection chamber in the PACE Sodr X Tractor is hot when the handpiece is in use When removing the chamber for cleaning grip the chamber at the rear seal Never touch the front end of t...

Страница 16: ...e AC supply receptacle must be checked to insure proper grounding before initial system operation 5 Assemble the Tip Tool Stand s and if desired attach to the power source Assembly instructions are enclosed with each stand 6 If you have purchased the optional Tip Temperature Selection System Chart Holder attach to the top of the power source using the supplied instructions 7 Install the Tip Temper...

Страница 17: ...N 6993 0136 Cable Marker Kit to identify the particular handpiece power cable and or air hose Attach any two like colored markers one to each end of the handpiece power cable or air hose Select and use a different color marker for each handpiece 11 If you have purchased the optional foot pedal insert the foot pedal connector plug into the Foot Pedal Receptacle on the rear panel of the power source...

Страница 18: ...SNAP VAC Port or Controllable PRESSURE Port at one time Attachment to both ports simultaneously will cause a deterioration of performance QUICK CONNECT METHOD To set up each air handpiece for the quick connect operation perform the following steps 1 Attach a 1 inch length 2 5cm of clear pvc Air Hose P N 1325 0003 07 to the metal tube in the back of each handpiece 2 To the other end of the 1 inch 2...

Страница 19: ...nd of a female quick connect hose mount Fitting P N 1259 0086 c Insert the ridged end of a male quick connect hose mount Fitting P N 1259 0087 in the free end of theAir Hose connected to the FLOW OUT side of the VisiFilter d Connect the VisiFilter Air Hose with attached male quick connect hose mount Fitting to the power source AUTO SNAP VAC Port SET UP Figure 6 VisiFilter Set Up 5 For vacuum inser...

Страница 20: ...nsert the ridged end of a male quick connect hose mount Fitting P N 1259 0087 in the free end of the Air Hose connected to the FLOW OUT side of the VisiFilter d Connect the VisiFilter Air Hose with attached male quick connect hose mount Fitting to the power source AUTO SNAP VAC Port SET UP Figure 7 Air Hose Connection Figure 8 VisiFilter Set Up 4 For vacuum insert the male quick connect hose mount...

Страница 21: ...he Controllable PRESSURE Port Attachment to both simultaneously will cause a deterioration in performance a All handpiece Tip Tool Stands set up as desired using instructions enclosed b Proper tips installed in handpieces c Power cord connection between the house AC supply receptacle and the power source 2 Turn the Power Switch to the On l position 3 Adjust the Variable Temperature Control of each...

Страница 22: ...setting for the channel powering the handpiece to obtain the desired True Tip Temperature VARIABLE TEMPERATURE CONTROL Adjust the Variable Temperature Control s to the desired temperature setting Notice that the control dial has a Gray scale denoting temperature in C Celsius and a Yellow scale denoting temperature in F Fahrenheit These numerical scales denote the set tip temperature times 100 e g ...

Страница 23: ...pulling on the Male Nib with the free hand to open the interconnection of the plastic housings at that Wing Tab c Pull against the second Wing Tab while pulling on the Male Nib to open the remaining interconnection and separate the plastic housings 5 Remove the old or discolored Element and discard 6 Insert the replacement VisiFilter Element into the housing marked FLOW IN Center the Element in th...

Страница 24: ...Replace Heater Assembly Fuse F1 Shorted Heater Replace Heater Assembly Fuse F1 No Ground on Tip Check resistance Pin 4 to a NEW Tip Resistance should be less than 2 ohms If not Oxidation buildup in Heater Bore Clean Heater Bore using appropriate wire brush Defective Heater Replace Heater Assembly HANDPIECES The following Heater Assembly Checkout Procedures are applicable to all PACE SensaTemp hand...

Страница 25: ...ce in the AC Receptacle Fuse Holder No heat on handpiece Other handpieces work on Power Source channel Defective Heater See Table l or refer to handpiece Manual No heat on handpiece Other handpieces do not work on Power Source channel Defective control circuit Contact PACE Customer Service Table II Power Source Corrective Maintenance Figure 12 Connector Plug Wiring Artisan Technology Group Quality...

Страница 26: ...CRIPTION PACE PART NUMBER MBT 201A MBT 101A MBT 201AJ MBT 101AJ MBT 201AE MBT 101AE 1 Power Switch 1157 0052 1157 0052 1157 0052 2 AC Power Receptacle Fuse Holder 1207 0151 1207 0151 1207 0151 3 Fuse F1 1 25A MBT 201A MBT 101A 1159 0217 N A N A 1 25A MBT 101AJ N A 1159 0251 N A 1 6A MBT 201AJ N A 1159 0256 N A 0 63A MBT 201AE MBT 101AE N A N A 1159 0214 4 Service Manual 5050 0340 5050 0340 5050 03...

Страница 27: ...nt Elements optional item 1309 0027 P50 1309 0027 P50 6 Bristle Brush Glass Chamber Cleaning 1127 0002 1127 0002 7 Power Cord 1332 0094 1332 0093 8 Tubing Clear PVC 1 Length Qty 2 1325 0003 07 1325 0003 07 9 Wire Brush 3 16 Dia 1127 0014 1127 0014 10 Wire Brush 1 8 Dia 1127 0006 1127 0006 11 Tip Cleaning Kit 6993 0151 6993 0151 12 AdapTip Kit 1 8 Tip to 3 16 Shank 1360 0083 P1 1360 0083 P1 13 Tip ...

Страница 28: ...093 7 Tubing Clear PVC 1 Length Qty 2 1325 0003 07 1325 0003 07 8 Wire Brush 3 16 Dia 1127 0014 1127 0014 9 Wire Brush 1 8 Dia 1127 0006 1127 0006 10 AdapTip Kit 1 8 Tip to 3 16 Shank 1360 0083 P1 1360 0083 P1 11 Tip Cleaning Kit 6993 0151 6993 0151 12 SX Tip Tool Stand 6019 0044 6019 0044 13 Tip Temp Selection System Charts booklet 5050 0251 5050 0251 REPLACEMENT PARTS Table V MBT 101A MBT 101AJ ...

Страница 29: ... Sodr X Tractor Filter 1309 0018 1309 0018 1309 0018 8 Holder Tube To Wire pkg of 6 1321 0085 01 1321 0085 01 1321 0085 01 9 Hose Clamp Metal qty 2 1211 0036 1211 0036 1211 0036 10 Male Quick Connect Hose Mount qty 2 1259 0087 1259 0087 1259 0087 11 Female Quick Connect Hose Mount 1259 0086 1259 0086 1259 0086 12 Fuse 1 25A Time Lag MBT 201A 1159 0217 N A N A 1 6A Time Lag MBT 201AJ N A 1159 0256 ...

Страница 30: ...21 0261 1121 0261 1121 0261 8 Desoldering Tip 1 8 Shank Angled 040 I D 1121 0262 1121 0262 1121 0262 9 Sodr X Tractor Filter 1309 0018 1309 0018 1309 0018 10 Holder Tube To Wire pkg of 6 1321 0085 01 1321 0085 01 1321 0085 01 11 Male Quick Connect Hose Mount qty 2 1259 0087 1259 0087 1259 0087 12 Female Quick Connect Hose Mount 1259 0086 1259 0086 1259 0086 13 Fuse 1 25A Time Lag MBT 101A J 1159 0...

Страница 31: ... 9215 9893 Brewers Court Laurel MD 20723 1990 U S A Document Nbr 5050 0381 Revision Level B Date of Submission Nature of Change Identify page and paragraph and include proposed rewrite if possible Reason for Recommendation Submitter Name Company or Organization Mailing Address Telephone Include Area Code Voice Fax Thank you for your comments they are greatly appreciated Artisan Technology Group Qu...

Страница 32: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...