SET-UP
HANDPIECE VACUUM/PRESSURE
AIR HOSE CONNECTION
There are two methods of attaching the Air Hose from the PACE power source to an air handpiece. Select the
method which best suits your needs. The Quick Connect Method is best suited for configurations where multiple
air handpieces may be in use. The Traditional Method is best suited for single air handpiece configurations.
CAUTION
Regardless of connection method, ensure that only one Air Hose is
connected to the VisiFilter assembly ( connected to the AUTO SNAP-VAC
Port) or Controllable PRESSURE Port at one time. Attachment to both
ports simultaneously will cause a deterioration of performance.
QUICK CONNECT METHOD
To set up each air handpiece for the quick connect
operation, perform the following steps.
1. Attach a 1 inch length (2.5cm) of clear pvc Air
Hose (P/N 1325-0003-07) to the metal tube in the
back of each handpiece.
2. To the other end of the 1 inch (2.5cm) clear pvc
Air Hose attach a female quick connect hose
mount Fitting (P/N 1259-0086). Secure this short
Air Hose to the handpiece power cable with one
cable clip (P/N 1321-0085-01).
Figure 5. Handpiece Quick Connect Hose