Safety Guidelines

 

The following are safety precautions that personnel must understand and follow when using or servicing this 
product. 

1. POTENTIAL SHOCK HAZARD 

- Repair procedures on PACE products should be performed by Qualified 

Service Personnel only. Line voltage parts may be exposed when the equipment is disassembled. 
Service personnel must avoid contact with these parts when troubleshooting the product. 

2.  All handpiece heaters and installed tips are hot when the handpiece is powered on and for a 

period of time after power off. 

DO NOT 

touch either the heater or the tip. Severe burns may 

result. 

3. PACE Tip & Tool Stands and handpiece cubbies are designed specifically for use with the 

associated handpiece and houses it in a manner that protects the user from accidental burns.   
Always store the handpiece in its holder. Be sure to place the handpiece in its holder after use and 
allow heater / tip to cool before storing. 

4. Always use PACE systems in a well ventilated area. A fume extraction system such as those 

available from PACE are highly, recommended to help protect personnel from solder flux 
fumes. 

5. Exercise proper precautions when using chemicals (e.g., solder paste). Refer to the Material 

Safety Data Sheet (MSDS) supplied with each chemical and adhere to all safety precautions 
recommended by the manufacturer. 

 

System Set-Up 

 
 Set up the Intelliheat™ system using the following steps. 
 

1.  Store the shipping container in a convenient location. Reuse of these 

containers will prevent damage if you store or ship your system. 

2.  Place the Power Switch in the “OFF” or “0” position.  

 

Mounting Options (ST 30, ST 50, ST 65, & ST 70) 

 

The power supply can be placed directly on a workbench or it also can also be mounted under a 
workbench or shelf to conserve space (

optional

 

mounting P/N 1321-0609-P1 bracket sold 

separately

).  To mount the system in this way: 

 
1.  Mount the bracket in the desired location (fasteners not supplied). 
2.  Insert the 2 Mounting Screws (head first) into the power source 

mounting slots. 

3.  Place the washers over the screws. 
4.  Fit the power source between the bracket’s support arms and place the 

screws into the slots on the support arms. 

5.  Place the nut on the screw and tighten by hand. 
6.  Angle the power source so the operator can see the front panel easily. 
7.  Tighten the nuts with a wrench or pliers. 

 
 

 
Tip & Tool Stand Mounting Option (For SX 90, PS 90, and TJ 85) 

 

Содержание IntelliHeat ST 30

Страница 1: ...B This manual applies to Model Part Number ST 30 7008 0290 01 ST 30E 7008 0290 02 ST 50 7008 0291 01 ST 50E 7008 0291 02 ST 65 7008 0292 01 ST 65E 7008 0292 02 ST 70 7008 0293 01 ST 70E 7008 0293 02...

Страница 2: ...led Power Supplies ST 30 ST 65 ST 75 Operation 10 Temperature Dial Lock 10 Analog Control LED Operation 10 Digital Temperature Controlled Power Supplies ST 50 ST 115 Operation 11 Digital Control LED O...

Страница 3: ...ce Requirements Domestic Models Export Models ST 30 ST 30E ST 50 ST 50E ST 65 ST 65E ST 70 ST 70E ST 75 ST 75E ST 115 Operates on 97 127 VAC 50 60Hz 80 Watts maximum at 115 VAC 60Hz ST 115E Operates o...

Страница 4: ...2012 PACE Inc Southern Pines North Carolina All Rights Reserved Page 4 of 20 Power Supply Features A A B B C D E F C G J I H D E L E K C O P Q R O P Q R S O P Q R ST 30 ST 50 ST 65 FRONT BACK...

Страница 5: ...2012 PACE Inc Southern Pines North Carolina All Rights Reserved Page 5 of 20 A B B M E N C L E K C D O P Q R ST 115 ST 75 R P T Q O ST 70 F C G J I H E L K R P T Q O...

Страница 6: ...menu functions I Digital control LED Indicates status of power supply J Digital display Displays temperature setting and menu functions K Vacuum inlet Vacuum connection for SX 90 TP 65 TP 100 Handpiec...

Страница 7: ...ighly recommended to help protect personnel from solder flux fumes 5 Exercise proper precautions when using chemicals e g solder paste Refer to the Material Safety Data Sheet MSDS supplied with each c...

Страница 8: ...pply Connection For ST 65 Only The ST 65 system utilizes an integral air venturi system to provide air pressure and vacuum for any connected PACE handpiece requiring air vacuum Your in house air suppl...

Страница 9: ...d end of a male quick fit connector P N 1259 0087 into the free end of the 1 inch 2 5cm length of air hose connected to the FLOW OUT side of the VisiFilter 3 Connect the free end of the 137cm 54 inch...

Страница 10: ...Temp Locking Ring closest to the front panel Dial Control LED Operation The colored LED on the power source front panel indicates Power Receptacle output status LED Full On Red A fault has occurred Ch...

Страница 11: ...offset may be entered if using massive tips To enter an offset simply press the program key while the system is in normal operation mode and enter the offset using the keypad The display will return t...

Страница 12: ...life and save energy the ST 50 and ST 115 systems can be programmed to automatically set back its Tip Temperature to 177 C 350 F after a selected period of handpiece inactivity adjustable 10 90 minut...

Страница 13: ...nd the system will return to normal operation If this occurs repeat steps 1 2 and enter the correct Password b The LED Display reads P Choose one of the following options i Press the Program Key to ke...

Страница 14: ...the following a Press and release the Program Key to keep the currently stored Auto Off time b Adjust the Auto Off value using the keypad c Press and release the Program Key to proceed to the next st...

Страница 15: ...the front of the unit 3 The LED indicator will turn amber while the tip is heating to the desired performance level 4 Once the tip has reached the desired heat level the LED indicator will turn green...

Страница 16: ...1 Green 5 260 C 500 F 1207 0446 02 P1 Turquoise 5 5 288 C 550 F 1207 0446 03 P1 Orange 6 316 C 600 F 1207 0446 04 P1 Gold 6 5 343 C 650 F 1207 0446 05 P1 Red 7 371 C 700 F 1207 0446 06 P1 Violet 7 5 3...

Страница 17: ...ter setscrew on the Variable Temperature Control knob furthest from front panel using the Temp Locking Key hex key supplied with the system c Position the knob with the pointer aligned to match the te...

Страница 18: ...he correct password Open Sensor Error No handpiece is connected to the power receptacle Connect handpiece The handpiece heater assembly sensor is open Refer to the appropriate handpiece manual Shorted...

Страница 19: ...p Time Lag 1159 0246 P5 1 Fuse 0 5 Amp Time Lag Export Models 1159 0213 P5 2 Silicone tubing For SX 90 TJ 85 Handpiece 1342 0015 08 3 Quick disconnect male fitting 1259 0087 P1 4 Venturi solenoid kit...

Страница 20: ...Y OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Seller will at its option repair or replace any defective products at its facility or other location approved by it at no charge to user or pro...

Отзывы: