©2012 PACE Inc., Southern Pines North Carolina All Rights Reserved
Page 9 of 20
Handpiece Vacuum/Pressure (ST 65, ST 75, & ST 115)
To set up your handpiece air hose connection, perform the following steps:
1.
Air Hose To Handpiece Connection
a) Attach one end of a 137cm (54 inch) length of air hose to the metal tube in
the back of the handpiece.
b) Attach the air hose to the power cable using the supplied Hose clips. Space them evenly along
the length of the power cable starting at a point 6 inches from the ends of the handpiece cable.
2.
When using vacuum
a) Prepare a VisiFilter (if needed) in the following manner:
1.
Connect a 1-inch (2.5cm) length of clear pvc air
hose to the FLOW OUT side of the VisiFilter.
2.
Insert the ribbed end of a male quick-fit connector
(P/N 1259-0087) into the free end of the 1 inch
(2.5cm) length of air hose connected to the FLOW
OUT side of the VisiFilter.
3.
Connect the free end of the 137cm (54 inch) length
of air hose to the FLOW IN side of the VisiFilter.
4.
Insert the end of the quick-fit connector (on VisiFilter
FLOW OUT side) into the power source Vacuum
Port.
3.
When using air pressure:
a)
connect one end of the 54” black air hose to the end of the handpiece
b)
Insert the ribbed end of a male quick-fit connector (P/N 1259-0087) into the free end of
this air hose .
c)
Insert the smooth end of the quick-fit connector into the pressure port of the system
and adjust pressure as required.
System Power Up
1. Insert the female end of the power cord into the AC Power Receptacle on the rear panel of
the power source.
2. Plug the prong end (male end) of the power cord into an appropriate 3 wire grounded AC
supply receptacle.