Pace DC900X Скачать руководство пользователя страница 7

7

DC900X INSTALLER’S MANUAL (501-3434310) RELEASE 30th Oct. 2009

BACKGROUND TO HOME CONTENT SHARING

TM

Network-Attached Storage

The DC900X Home Content Sharing (HCS) server is connected into a home network. It serves as a single network-attached storage (NAS) device for 
shows (content) that can be recorded by up to three “client” set-tops at different locations in the home. These set-tops do not have their own DVR 
capability – instead they all share the hard disk in the NAS. 

MoCA networks

MoCA (Multimedia over Coaxial Alliance) is a method of sending extra signals over the existing coaxial cables in a home. Whereas the normal in-band 
signals for TV shows use frequencies in the range 54 MHz to 860 MHz on the coaxial cable, the MoCA signals use the range 1.15 GHz to 1.5 GHz on the 
same cable. The signals do not interfere with each other because of the different frequency ranges. Low-pass filters are used to prevent the MoCA signals 
from getting to places where they would cause problems (for example on the main cable network outside the home). Other RF equipment connected to the 
coaxial network should be immune to MoCA signals, but, if there are problems, use a low-pass filter between the equipment and splitter.

In the near future, client set-tops will have MoCA capability built into them. Until then, regular non-DVR set-tops, such as the DC700X, can be used as 
clients, in conjunction with MoCA dongles (also known as Ethernet-Coax bridges or ECBs). The client set-tops are connected to the MoCA dongles by 
Ethernet (Cat5e/Cat6) cables. See the diagrams below and on page 8.

MoCA-Ethernet hybrid network

The diagram below shows the signals in a MoCA-Ethernet hybrid network. One client is connected to the NAS directly by Ethernet cable. Therefore 
recordings and play-back to client set-top 3 are done only via the Ethernet cable. Recordings and playback to client set-tops 1 and 2 are done via the 
Ethernet cables and the MoCA network on the coaxial cables. The diagram on page 8 is the same network but with typical equipment and cables. The 
diagram on page 10 shows a typical in-house scenario.

You cannot use more than three client set-tops in the MoCA-Ethernet hybrid network. If each of the two dual-tuner clients that are using MoCA is making 
two recordings at the same time, and, at that same time, a recording is being played back to each set-top, then 95% of the MoCA bandwidth will be used.

Point of entry

Low-pass

filter

MoCA

dongle

Client

set-top 3

Client

set-top 1

MoCA

dongle

Client

set-top 2

Low-pass

filter

HCS server

(NAS)

Coaxial splitter

Coaxial cable

Ethernet cable

Ethernet signals

In-band signals 54 to 860 MHz

MoCA signals 1.15 to 1.5 GHz

Splits the cable input to the various 
devices on the MoCA network.

In-band signals to NAS are for 
software upgrades only.

MoCA signals to NAS are for 
recording and play-back for 
client set-tops 1 and 2.

Prevents MoCA signals getting onto 
the cable network outside the home.

In-band signals to all three 
clients are for live TV shows.

Ethernet signals to NAS are 
for recording and play-back 
for client set-top 3.

Ethernet signals to the MoCA dongles 
are for recording and play-back for client 
set-tops 1 and 2.

MoCA dongles (Ethernet-Coax bridges) 
also contain a low-pass filter to prevent 
MoCA signals reaching client set-tops 
1 and 2.

Prevents MoCA signals reaching client set-top 3.

Содержание DC900X

Страница 1: ...MoCA LAN DC900X BRINGING TECHNOLOGY HOME www pace com INSTALLATION GUIDE Pace DC900X for Home Content Sharing RELEASE 30th Oct 2009...

Страница 2: ...lter at client set top 3 11 Connecting a low pass filter at the POE 11 Connecting up client set tops 1 and 2 11 POWERING UP THE NETWORK AND SWITCHING ON OFF 12 Checking connections 12 Powering up the...

Страница 3: ...efore you install or use the apparatus you must read and understand these Important Safety Instructions At all times when using the apparatus you must follow these Important Safety Instructions to red...

Страница 4: ...allation such as a bookcase or rack unless proper ventilation is provided and you have adhered to the manufacturer s instructions Maintain a minimum distance of three inches around the NAS and client...

Страница 5: ...rial number and electrical rating of this NAS are on a label on its base SATA DC IN 2 0A 12V ETHERNET CABLE IN WHEN SERVICING USE ONLY IDENTICAL REPLACEMENT PARTS CAUTION SATA DC IN 2 0A 12V ETHERNET...

Страница 6: ...ER light around button Lights green when the NAS is on red when the NAS is off standby not lighted when the NAS is disconnected from the power supply MoCA light Lights up green when there are MoCA sig...

Страница 7: ...8 MoCA Ethernet hybrid network The diagram below shows the signals in a MoCA Ethernet hybrid network One client is connected to the NAS directly by Ethernet cable Therefore recordings and play back t...

Страница 8: ...LE INSULATED AUDIO OUT L R CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION WHEN SERVICING ONLY USE IDENTICAL REPLACEMENT PARTS ETHERNET CABLE IN Prevents MoCA signals getting onto the cable network...

Страница 9: ...AUDIO OUT OPTICAL VIDEO OUT Pr Pb Y COMPONENT VIDEO 1394 CABLE IN TO TV SATA IR RECEIVE POWER INPUT 120V AC 60Hz DOUBLE INSULATED AUDIO OUT L R CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION WHEN...

Страница 10: ...L R CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION WHEN SERVICING ONLY USE IDENTICAL REPLACEMENT PARTS ETHERNET ANTENNA RF IN LEFT AUDIO IN RIGHT AUDIO IN VIDEO IN POWER HDTV PB CB IN PR CR IN Y I...

Страница 11: ...6 cable between the Ethernet connectors on the NAS and client set top 3 Connect the 12 V power supply unit to the DC IN connector on the NAS but do not yet apply power to the NAS you must do this afte...

Страница 12: ...urn on each client set top so that its POWER light is green Wait for the whole system to get established and running This should happen within six minutes When the client set tops are communicating co...

Страница 13: ...elect OK Exit POWER Home Content Sharing Enable Disable Programming the remote control for Home Content Sharing Program the remote control for each of the client set tops to give one touch access to H...

Страница 14: ...Make sure you have enabled HCS at the client set tops see page 13 Noting the appropriate MAC addresses MAC addresses should be on labels on the equipment You will need these MAC addresses when you vie...

Страница 15: ...return to normal TV viewing press the POWER button twice Relevant information on the DIAGNOSTICS DASHBOARD Check the following items on the DIAGNOSTICS DASHBOARD for a green GOOD status MoCA Network...

Страница 16: ...ld or damage coaxial cables check the cabling loose or damaged F type connectors use crimped connectors rather than screw on type coax splitters that are not rated up to 1 5 GHz make sure that they ar...

Страница 17: ...ut of band signals on the coaxial cable It is another representation of the Bit Rates in the Node Status screens For non NAS nodes the status is good if the numbers on this screen are 0 at the beginni...

Страница 18: ...press OK Select or R If you choose this second method the HCS Home Content Sharing sub menu is displayed Use the U or D button to highlight NAS then press OK Select The NAS Diagnostics screen will th...

Страница 19: ...eleases of the NAS software ETHERNET NETWORK screen HARDWARE VERSION screen This screen lists the client set top that is attached directly to the NAS by Ethernet cable The MAC address is the one given...

Страница 20: ...powered on again when the temperature falls to 145 F 63 C Check the ventilation requirements see page 4 if the hard disk switches off QAM TUNER screen The NAS contains a QAM tuner to provide a path fo...

Страница 21: ...23 HDD STATUS on the DIAGNOSTICS MAIN MENU and then press OK Select The Hard Disk Drive HDD Status Menu is displayed on screen with the DRIVE NUMBER field marked with as shown below Using the DVR Stat...

Страница 22: ...of the client set tops to check that the recording has taken place Displaying the My Network screen You must display the My Network screen at each of the client set tops in turn to check that the whol...

Страница 23: ...to highlight each recording in turn then press OK Select to ensure that it plays back correctly To test the network thoroughly set up each client set top to simultaneously record two shows and play ba...

Отзывы: