©2018 PACE Inc., Vass, North Carolina. All Rights Reserved
•
Rugged steel case construction and heavy-duty motor pumps for years of trouble-free use
•
Low cost, easily changed, disposable filter cartridges
•
Superior performance and quiet operation
•
Optimal flow rates for use with our flexible arms & accessories
The Arm-Evac 150 comes standard with a General Purpose Combo Filter with a 3-stage filtration process
consisting of a Pre-Filter for course particle removal, a HEPA-Type Particulate Filter and Gas Filter in a cartridge
for efficient filtration. Several types of filters are available:
1. A General-Purpose Combo Filter for normal benchtop soldering and electronics rework applications
(supplied with system).
2. A Clean Room Filter for use in cleanroom environments.
3. An Adhesive Filter intended for removal of fumes produced by light benchtop gluing or PCB cleaning
applications involving light benchtop solvent use (no solvent tanks).
4.
A High Capacity Filter and High Capacity Pre-Filter for longer maintenance intervals during normal
soldering operations
.
See Replacement Filter Chart on page 8 for full range of filters and part numbers.
The Arm-Evac 150 Fume Extractor uses specially designed extraction accessories that can be conveniently
mounted on any workbench or tabletop. The Arm-Evac 150
®
can be used to extract fumes from up to two
different work benches/collection points.
Specifications
Arm-Evac 150 System Part Number
8889-0150-P1 for 110V, 60hz unit
8889-0155-P1 for 230V, 50hz unit
Flow Rate with General Purpose Combo Filter
Single Inlet: 155 cfm
Dual Inlet: 90 cfm each Arm
Flow Rate with Optional Cleanroom Filter
Single inlet: 145 cfm
Dual inlet: 85 cfm each
Sound Level DbA
< 53 dbA 50% motor speed
< 63 dbA 100% motor speed
Weight (Central Filtration Unit with Filter)
9.07 Kg/20 lbs
Size W x D x H
305mm W x 305mm D x 432mm H
(12
” W x 12” D x 17” H)
Housing
20-gauge steel (ESD-safe)
Flex Arm Diameter
60mm (
2.4”)
Maximum Number of Flex Arms
2
Environmental Specifications
Ambient operating temperature
0ºC to 80º (32ºF to 176ºF)
Storage temperature
-40ºC to 125ºC (-40ºF to 257ºF)
Ambient operating humidity
90% relative humidity max non-condensing
Storage humidity
90% relative humidity max non-condensing