Section 9
Routing
9-4
12/11
Routing of Wires and Hoses near Exhaust System
TABLE 9-1.
Exhaust – System Clearance
Description
Shielded
Unshielded
Coolant hoses, HVAC hoses and tubing, and electrical wires
within 15” of the turbo and/or over 15” from the turbo
2” minimum
3” minimum
Fuel hoses
within 15” of the turbo
over 15” from the turbo
n/a
2” minimum
4” minimum
3” minimum
Fuel tanks and hydraulic tanks
crossing tank
parallel to tank
end of tank
aluminum/ceramic-coated exhaust pipe crossing tank
n/a
n/a
n/a
n/a
2” minimum
2” minimum
1” minimum
1 .5” minimum
Air hose
nylon
wire braid
3” minimum
2” minimum
8” minimum
3” minimum
Electrical wires (located at or down line of the DPF)
3” minimum 8” minimum
Exhaust system
(pipe, muffler)
Heatshield (or blanket)
Component
Shielded dimension
Unshielded dimension
FIGURE 9-5.
Definition of measurements.
Содержание Kenworth T170 Hybrid 2011
Страница 1: ...Kenworth T170 T270 T370 and Hybrid 2011 Body Builders Manual...
Страница 2: ......
Страница 10: ...12 11 Section 1 Introduction Page Intentionally Left Blank...
Страница 52: ...Section 3 Dimensions 3 34 12 11 Automatic Transmission Allison 3000RDS...
Страница 53: ...3 35 Section 3 Dimensions 12 11 Manual Transmission...
Страница 111: ...Section 5 Frame Layouts 5 40 12 11 Page Intentionally Left Blank...
Страница 120: ...Section 6 Body Mounting 6 9 12 11 Page Intentionally Left Blank...
Страница 128: ...Section 7 Frame Modifications 7 8 12 11 Page Intentionally Left Blank...
Страница 137: ...Section 8 Electrical 8 9 12 11 FIGURE 8 10 Fuel Filter Restriction Pressure Gauge Sensor Location typical...
Страница 165: ...Section 8 Electrical 8 37 12 11 FIGURE 8 31 Cab Load Center mPDC...
Страница 170: ...Section 8 Electrical 8 42 12 11 Page Intentionally Left Blank...
Страница 179: ...12 11 Kenworth Truck Company P O Box 1000 Kirkland WA 98083 425 828 5000...