![PAC RSIC-SI-CRC EZ Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/pac/rsic-si-crc-ez/rsic-si-crc-ez_installation-manual_3139658002.webp)
Drywall Furring Channel:
Furring Channel:
25 gauge hemmed edge, or 20 gauge standard.
Meets or exceeds SSMA requirements.
Depth:
7/8 inch
Width Bottom:
2-9/16” to 2-11/16” inch wide nominal.
Width Top:
1-1/4 inch wide
Splice drywall furring channel (hat track) with 6 inch overlap in mid
span (between two clips) secure with 18 ga tie wire, or two 7/16”
framing screws.
RSIC-SI-CRC EZ Spring Isolator
Maximum Spacing:
48” oc. with Cold Rolled Channel
Finish elevation is 1/2” below preset height.
Silver = 80 Lbs
Red = 40 Lbs
Green = 30 Lbs
Blue = 20 Lbs
White = 10 Lbs
Yellow = 5 Lbs
RSIC-SI-CRC EZ SOUND ISOLATION CLIP
PAC International, LLC. All Rights Reserved.
• (866) 774-2100 • Fax (866) 649-2710
RSIC® is a registered Trade Mark of PAC International, LLC.
PAC International, Inc. Tel: (866) 774-2100 Technical: (866) 649-2710 Web Site: www.pac-intl.com
10 Lb
20 Lb
30 Lb
40 Lb
80 Lb
5 Lb
Carrier Channel Options:
48” spacing 16 Gauge Cold Rolled Channel (CRC)
Dim: 1/2” x
1.5” x 1/2” SSMA code: 150U050-54
CRC and Steel Studs must meet or exceed SSMA standards
Fasteners:
RSIC-SI-CRC EZ to Wood:
#8 x 1-5/8 inch minimum size coarse
thread screw. (Recommended #12 or #10 x 1-5/8 inch hex head)
RSIC-SI-CRC EZ to Steel:
# 8 x 1inch minimum size fine thread
screw. (Recommended #12 or #10 x 1inch hex head)
1.5” x 16 Gauge Cold Rolled Channel (CRC) 1/2” x 1.5”
Use min
9/16” self drilling framing screws to fasten the 1.5” CRC channel
RSIC-SI-CRC EZ
CRC and Steel Studs must meet or exceed SSMA standards
- ”
”
”