Drywall Furring Channel:

 

Furring Channel: 

25 gauge hemmed edge, or 20 gauge standard. 

Meets or exceeds SSMA requirements.

 

Depth:

 7/8 inch

 

Width Bottom:

 2-9/16” to 2-11/16” inch wide nominal.

 

Width Top:

 1-1/4 inch wide

Splice drywall furring channel (hat track) with 6 inch overlap in mid  
span (between two clips) secure with 18 ga tie wire, or two 7/16” 
framing screws.

RSIC-SI-CRC EZ Spring Isolator

 

Maximum Spacing: 

48” oc. with Cold Rolled Channel

 

Finish elevation is 1/2” below preset height.

 

Silver = 80 Lbs

 

Red = 40 Lbs

 

Green  = 30 Lbs

 

Blue = 20 Lbs

 

White = 10 Lbs

 

Yellow = 5 Lbs

RSIC-SI-CRC EZ SOUND ISOLATION CLIP

PAC International, LLC. All Rights Reserved. 

• (866) 774-2100 • Fax (866) 649-2710

RSIC® is a registered Trade Mark of PAC International, LLC.

PAC International, Inc.  Tel: (866) 774-2100 Technical: (866) 649-2710 Web Site: www.pac-intl.com

10 Lb

20 Lb

30 Lb

40 Lb

80 Lb

5 Lb

Carrier Channel Options:

 

48” spacing 16 Gauge Cold Rolled Channel  (CRC)  

Dim: 1/2” x 

1.5” x 1/2”  SSMA code: 150U050-54

 

CRC and Steel Studs must meet or exceed SSMA standards

Fasteners:

 

RSIC-SI-CRC EZ to Wood: 

#8 x 1-5/8 inch minimum size coarse 

thread screw. (Recommended #12 or #10 x 1-5/8 inch hex head)

 

RSIC-SI-CRC EZ to Steel: 

# 8 x 1inch minimum size fine thread 

screw. (Recommended #12 or #10 x 1inch hex head)

 

1.5” x 16 Gauge Cold Rolled Channel  (CRC) 1/2” x 1.5” 

Use min 

9/16” self drilling framing screws to fasten the 1.5” CRC channel 
RSIC-SI-CRC EZ

 

CRC and Steel Studs must meet or exceed SSMA standards

 -   ”  

 ” 

   ” 