Swimming Pool Heat Pump 

 

 

 

User manual

 

 
 

MODEL : 

 

 

KS8R 

KS12R 

KS15R 

KS20R 

 
 
 
 

 
 
 
 
 

 

 
 
 
 

 

 

 

  

 1

www.pac-direct.com

Содержание KS12R

Страница 1: ...Swimming Pool Heat Pump User manual MODEL KS8R KS12R KS15R KS20R 1 www pac direct com...

Страница 2: ...e filtration pump is working At the beginning of the season or when the outside temperature is low you must increase the daily filtration time so that the Heat pump can overcome thermal losses of the...

Страница 3: ...risk of overheating Keep out of reach of children and do not to let them play nearby inform them of the dangers of this machine Never introduce a stick or your fingers into the protective grille of t...

Страница 4: ...mes wet you might observe a thin layer of white frost on the gilds of the radiator This is normal To avoid a strong thickness of white frost which would prevent the air to circulate through the gilds...

Страница 5: ...After starting Ensure that operation is regular if high vibrations occur stop the Heat pump and call your fitter Instructions Careful The first pressure on the key ON OFF gives the authorization of st...

Страница 6: ...re desired Adjustment of the stop temperature in cold period Adjustment of the start and stop hour Choosing the heating or the cooling mode On off Defrost forced To adjust the hour Error messages The...

Страница 7: ...ton ON OFF Start between 1 second and 4 minutes in the last active mode heating or cooling Go from heating mode to cooling mode or inversely from cooling to heating Press the button MODE Stop for 4 mi...

Страница 8: ...to confirm the setting 2 Press Timer on to enter timer setting to start the unit Press key adjust hour number Press Timer on again to adjust minute number Press Timer on once more to confirm the sett...

Страница 9: ...emptying THE EXCHANGER MIGHT BURST IF IT HAS NOT EMPTIED COMPLETEY Put back each pipe to its place and screw again the connections to entirely close again to avoid little animal s entry Remark supplem...

Страница 10: ...nt in the evaporator E 5 Magnetic ammeter The compressor stops 3 times in 24h because of intensity excess in the compressor Environment problem See DIRECTIONS FOR INSTALLATION AND MAINTENANCE E 6 Comp...

Страница 11: ...of the condensates not installed or stopped black plastic conduit prolonged with a flexible pipe of evacuation It s natural these condensates are caused by condensation of the humid air on the gilds...