Safety Specification 

 

 

 

Danger: Electrocution hazard - Electricity can cause DEATH or SERIOUS INJURY 

 

DO NOT use bare wire to connect power supply to electrical equipment, use a plug that 

meets local regulations. 

 

During generator operation, do not touch exposed wires. 

 

During generator operation, keep children a safe distance from the generator unit. 

 

DO NOT use the generator unless it is fully assembled as instructed in this manual. 

 

Properly ground the generator and verify grounding is in place before each use. Grounding 

regulations vary by location, consult a qualified electrician for verification. 

 

Accessories including cables and plug must not be defective. Electric shock prevention 

hinges on the breaker. If you renew the breaker use a breaker with the same rating and 
performance features, contact your local authorized service agent. 

 

Danger: Fuel used by the generator is combustible, as this equipment generates high 
temperature, this causes a fire risk in some circumstances , such as refueling. 

 

It is strictly prohibited to add fuel while the generator is operating; 

 

When adding fuel, keep far away from any ignition source, and NO smoking; 

 

When adding fuel, pay attention not to spill fuel on the equipment, if fuel is spilt

; 

clean it immediately, and only start it up when the spilt fuel has evaporated completely; 

 

During operation, be sure there are no combustibles within a 2m range. 

 

In case of long-term nonuse, make sure you use a fuel stabilizer or empty the fuel tank and 

bowl. 

 

Caution: This equipment contains high speed revolving parts, which may cause injury. 

 

During generator operation, avoid coming into contact with any revolving parts. 

 

During generator operation, observe surroundings, make sure there is no risk to the 

generator, other people and nearby equipment. 

 

 During generator operation, do not lift or re-position. Turn the generator off ensuring it has 

come to a complete stop. 

 

Attention: operating requirements 

 

Do not place weight on the equipment. 

 

The wheel is adopted for convenience of equipment moving, do not use it in long distance, 

otherwise it will be damaged. 

 

Do not exceed rating power of the equipment in operation; otherwise, its service life will 

be shortened. Power of common household appliances is shown on Page 14 in details. 

 

Maintain the equipment based on requirements so as to prolong its service life, refer to 

Page 15-17 for details. 

 

Operate and store the generator in a dust free area this prevents dust entering inside of the 

equipment which reduces its working life. 

Содержание P10000LE

Страница 1: ...FOR YOUR SAFETY You must read and understand this manual before use Keep this manual for future reference...

Страница 2: ...n 6 Warning Labels 7 Product Specifications 8 Component Identification 9 Features 10 Operating Guide 11 Operating 12 Power Management 14 Maintenance 15 Trouble Shooting Guide 18 Recycling Product Disp...

Страница 3: ...l safety warnings in this manual and on the generator Instruct others on the proper use of this generator and be sure they are familiar with all safety warnings in this manual before use It is impossi...

Страница 4: ...rning Do not use this generator if exposed to rain or if wet and store in an enclosed area when not in use Warning Keep the generator clean remove any petrol or oil spills on or around the generator D...

Страница 5: ...dding fuel pay attention not to spill fuel on the equipment if fuel is spilt clean it immediately and only start it up when the spilt fuel has evaporated completely During operation be sure there are...

Страница 6: ...6 Safety Regulations There is the warning decal on the machine to remind you of the safety regulations...

Страница 7: ...y result in an electric shock Electricity Do Not Touch The device produces electricity do not touch during operation Toxic Gas Exhaust gas from this generator contains Carbon Monoxide CO a colorless o...

Страница 8: ...ngine Type 4 Stroke Air Cooled Single Cylinder OHV Oil Capacity 1 1L Starting Method Electric Recoil Displacement 457cc Frequency 60hZ Voltage 220V 240V Power Factor 1 0 Rated Power 7500W Max Power 83...

Страница 9: ...action Fuel tank Oil tank cap Control Panel AC Circuit Breaker Chock valve Fuel Valve Air filter Recoil Starter Grip AC output Engine switch Wheel Handle Grips Oil drain Plug Spark plug Carburetor Muf...

Страница 10: ...e engine FUEL TANK The fuel tank has a capacity of 15 liters 25 liters FUEL VALVE Fuel flow from the fuel tank to the engine is turned on and off using the fuel valve Turn fuel off after use GROUND TE...

Страница 11: ...d fire hazard and from the ground to avoid slipping Fill fuel oil Do Not exceed this level Open the fuel fill cap and fill with fresh Unleaded petrol The fuel level position will be displayed on the i...

Страница 12: ...urn the switch for more than 3 seconds and the interval between two attempts should be at least 10 seconds apart b For the manual start generator by pulling the recoil starting grip until the engine r...

Страница 13: ...own and it should not be moved or touched before cooling down to avoid the possibility of burns The unit should be stored in a clean and dry place and should be protected from rain and high temperatur...

Страница 14: ...Refrigerator 800 1600 Washing machine 300 600 Electric fan 50 100 Air conditioner 2HP 1500 3000 Tools Electric welder 2500 5000 Electric hammer 1000 1500 Water pump 800 1200 The starting wattage of s...

Страница 15: ...Every 100 hours or every 6 months 3 Every 300 hours or every year 3 Engine oil Inspect the oil level Replace Air filter Inspect Clean 1 Fuel strainer bowl Clean Spark plug Clean Replace Valve clearan...

Страница 16: ...xcess by squeezing into a dry clean cloth 4 Refit the air filter and air filter cover Clean the fuel bowl Fuel valve Sedimentation glass Strainer O type seal ring Sedimentation glass 1 Close the fuel...

Страница 17: ...gauge The clearance should be kept between 0 70 and 0 80mm 6 Inspect if the washer of the spark plug is in good condition 7 Reinstall the spark plug and tighten it with the spark plug socket spanner P...

Страница 18: ...e load to the rated limit The unit emits blue smoke The engine oil is overfilled Drain oil to correct level The engine oil type is incorrect Choose appropriate engine oil model refer to page 11 The po...

Страница 19: ...h your local authority or recycling centre 5 Certain products contain batteries which should not be disposed of in your domestic waste 6 You MUST recycle batteries in accordance with your local author...

Страница 20: ...nform to the following CE directives 97 68 EC Non Road Mobile Machinery Directive 2000 14 EC Outdoor Noise Directive 2004 108 EC Electro Magnetic Compatibility Device 2006 42 EC Machinery Directive P1...

Страница 21: ...wer Limited London Road Pembroke Dock Pembrokeshire SA72 4RW UK Telephone 44 0 1646 687880 Fax 44 0 1646 686198 Website www p1pe co uk To register your machine for the manufacturer s warranty please v...

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...P1PE Position One Power Equipment Isaac Way Pembroke Dock Pembrokeshire SA72 4RW UK www p1pe co uk...

Отзывы: