11
The operational steps are pasted above the fuel
tank, . please operate as per the instructions.
Unit grounding
Shift the machine outdoors, use the
grounding terminal connection wire to
ground to earth. One end of the wire is
pressed below the butterfly nut on the unit,
screw it up tightly, and the other end is
connected with the metal rod that is inserted
into the ground.
Pre-operational
Add engine oil
Unscrew the oil dip stick, add engine oil
SAE10W/30 (oil requirements may vary
if operating in extreme temperatures, refer
above table). Fill the oil to the top of the thread
(indicated as "Correct Oil Level" above).
If oil is spilt wipe off machine to avoid fire
hazard and from the ground to avoid slipping.
Fill fuel oil
Do Not exceed this level
Open the fuel fill cap and fill with fresh
Unleaded petrol.
The fuel level position will be displayed on the
indicator opposite the fuel cap. When filling the
tank the maximum fuel position shall not
exceed the inner strainer of the Fuel tank as
indicated above.
Warning
: keep away from any possible
ignition source when filling petrol; do not
fill the fuel tank while the generator is in
operation.
Connect electric battery (electrical
starting only)
Connect the battery, red for positive terminal and
green for the negative terminal and make sure you
tighten the nuts. Pay attention and avoid contact
between positive and negative terminal to eliminate
the chance of short circuit. Make sure you place
the rubber protective covers over the terminals.
Operating Guide