11.1 Standard Stand Off in Solid Cutting
This is the typical and most commun cutting type; you can adjust the current from a minimum of 20A to a maximum of 100A. Once the cutting is terminated the arc strikes off and it can
be reactivated pressing the torch trigger once again. Use always the spacer (11) unless you have particular precision needs as described in “GRATING” paragraph.
The solid cutting can be performed in three modes:
A) Contact, precison cutting without using the spacer
B) Standard stand off for a current up to 70A
C) Standard stand off for a current higher than 70A
A) Contact precision cutting
Use
Code
3 electrode
Z0060AA
4 gas diffuser
Z0061AA
6 cutting tip 0,9 Z0063AA
9 outer nozzle
Z0070AA
P-Tronic 100
B) Standard stand off for current up to 70A
Use
Code
3 electrode
Z0060AA
4 gas diffuser
Z0061AA
9 outer nozzle
Z0070AA
11 double pointed spacer
Z0072AA
for current 40
÷
50 A
7 tip cutting 1,0
Z0064AA
for current 40
÷
50A
7 tip cutting 1,1
Z0065AA
for current 50
÷
60A
7 tip cutting 1,2
Z0066AA
for current 60
÷
70A
C) Standard stand off for current 70A - 100A
Use
Code
3 electrode
Z0060AA
5 gas diffuser
Z0062AA
10 outer nozzle
Z0071AA
11 double pointed spacer
Z0072AA
8 tip cutting 1,4
Z0067AA
for current 80
÷
90A
8 tip cutting 1,5
Z0068AA
for current 100
÷
110A
8 tip cutting 1,6
Z0069AA
for current 110
÷
120A
Note: the current must be set less than 40A, it is suggested the grating set.
Note: the spare parts are the same if the straight automatic
torch is used.
P-Tronic 100
P-Tronic 100
P-Tronic 100
- 11 -
Содержание 40P
Страница 2: ......
Страница 23: ...GB English Instruction Manual P Tronic 40P 70 100 18 ELECTRIC WIRING DIAGRAM 19 P Tronic 40P...
Страница 25: ...GB English Instruction Manual P Tronic 40P 70 100 20 ELECTRIC WIRING DIAGRAM P Tronic 70 21...
Страница 28: ...GB English Instruction Manual P Tronic 40P 70 100 22 ELECTRIC WIRING DIAGRAM P Tronic 100 23...
Страница 29: ......