background image

Glueboard Replacement

Tube Replacement

GLUEBOARD REPLACEMENT

GLUEBOARD REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER 

ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.

The glueboard should be replaced every month with a genuine glupac

®

 glueboard.  Use of 

non-approved glueboards may invalidate your guarantee.

To replace the glueboard…

 1. 

Position 

Flypod

®

 so the back is facing you.  

 

2. Using one hand to support the unit, use your thumb and forefinger of your other hand  

 

    to gently pull the used glueboard out through the slot in the back of the unit.    

 

3. Once free from the unit, dispose of the used glueboard hygienically.

 

4. Remove the protective release paper from the new glupac

®

 glueboard.

 

5. Slowly slide the new glueboard into position along the two runners with

 

    the adhesive side facing the tube.

Always ensure the selected genuine glupac

®

 glueboards are compatible with your unit, available 

from your pest control operator or P+L Systems Ltd.

TUBE REPLACEMENT

TUBE REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER ENSURING THAT 

THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.

To ensure the efficiency of Flypod

 

®

 in catching flying insects, the UV tube should be replaced 

annually.  After twelve months the phosphor coating that emits the correct wavelength of UV light 

has burnt away and the UV output is diminished substantially. 

To replace the UV tube...

 

1. Pull the tube gently from the tube holder until it un-clips. 

 

2. Dispose of the used UV tube in conjunction with local WEEE regulations.

STARTER REPLACEMENT

STARTER REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER ENSURING 

THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.

The starter provides an extra spark to initially light the UV tube.  Starters wear out and should be 

replaced at the same intervals as the UV tube.

To replace the starter…

 

1. Remove the glueboard from the units described above.

 

2. Rotate the starter anti-clockwise.

 

3. Pull the starter free from the unit.

Unit  

 

Flypod

Voltage  

 

230V - 50Hz

Dimensions (mm) 

200 x 310 x 170

Coverage   30 

Sq. Meters

Weight  

 

1.5kg

Light Output 

 

18W

Tubes  

 

1 x TPX18

Starter  

 

1 x I154

Glueboard (x6)   

INF252 (White)

SPECIFICATION / REPLACEMENT PARTS

Starter Replacement

R4  03/14

C

2014

P+L Systems Ltd

Information provided on these instructions is modified and 

updated from time to time.  This is due to the constant 

redevelopment of our products.  As such, it is not intended that 

you should rely on it or that it should form part of any contract.  

Sterling House
Grimbald Crag Close
Knaresborough
North Yorkshire
HG5 8PJ      UK

T  +44 (0)800 988 5359
F  +44 (0)1423 863 497
W  www.pandlsystems.com
E  [email protected]

WEEE Compliance No. WEE/GF0661QR

Отзывы: