ATTENTION: Install in accordance with national and local building and electrical codes.
!
!
Alpha / Beta Reflector: Chain Mount
Installation Instructions
NXT-LP
1
Prepare Light Fixtures
• Arrange boxed light fixtures on floor in specified
mounting locations; remove fixtures and mounting
accessories from boxes.
4
Adjust and Secure Reflector
• Using both hands, adjust the reflector from the
inside, by gently pressing outwards until the outer
rim fits securely beneath the collar tabs on all sides.
Note:
Wear cotton gloves or wash hands thoroughly with soap & water
to remove any grime/oils before handling reflector.
2
Install Eye Bolt(s)
• Eyebolts (can be installed in single or dual locations
on the back of the housing.
• Thread eyebolt into desired location(s) and tighten.
Note:
Dual eyebolts are recommended for levelling purposes.
3
Insert Reflector into Collar
• Slide reflector into collar at an angle, so that
outer rim is inserted beneath the collar tabs.
Note:
Wear cotton gloves or wash hands thoroughly with soap & water
to remove any grime/oils before handling reflector.
© P.L. Light Systems, 4800 Hinan Drive, Beamsville, Ontario, Canada, L0R 1B1 T: 905.563.4133 Toll Free: 1.800.263.0213 www.pllight.com
NXT_LP_Alpha_Beta_Chain Mt_10.19
PAGE
1 of 3
eyebolt locations
single eyebolt
dual eyebolt
NOTE: You will need to purchase
2x lengths of chain to mount the
product. Length of the chains will
depend on the desired mount
height above the crop.
5
B
• Slide lamp holder locks back in place to secure
lamp.
• Ensure that the sliding mechanism has fully closed
against the stop.
Note:
Always wear cotton gloves when handling double-ended lamps.
5
A
Install Lamp
• Slide the plastic locks outwards.
• Install lamp, ensuring side with “getter” is closest to
electronics compartment and melting point is facing
down (away from fixture) if possible.
Note:
Always wear cotton gloves when handling double-ended lamps.
Getter
Melting Point