1.
Install the compressor on a horizontal, flat platform, taking into account its mass and overall dimensions.
2.Provide free space for compressor mainte-
nance.
3.To maintain operating temperatures within
normal limits, install the compressor in places
with sufficient ventilation. The air temperature
in the room should be b 5 ° and +
35°C. It is not allowed to operate the compres-
sor in unheated rooms. In case of insufficient
ventilation, it is necessary to ensure the flow of
sufficient air to cool the compressor and to
discharge hot air from the room. Do not allow
hot air to recirculate.
3.Do not install the compressor in places where
the temperature may be less than + 5 ° С and
the altitude above 2000m
4.The normal temperature of the compressor is
80 ° С, the oil in the crankcase is 70 ° С.
5.Voltage fluctuations should not exceed ± 5%
of nominal.
6.The oil level in the crankcase must not be
below the red mark of the oil level indicator.
7.It is necessary to let the compressor run for
1-2 minutes for better distribution of oil.
8.Use only pure oil.
Compressor Start and Operation.
1.
Install the compressor on a horizontal, flat platform, taking into account its mass and overall dimensions.
1.
Carefully read and follow the instruction
manual.
2.
Open the package, check the complete-
ness, and make sure there is no damage.
3.
Install shock absorbers and wheels on
the receiver.
4.
Remove the oil filler cap.
5.
Fill the crankcase with oil and tighten the
oil filler cap. Check the oil level on the oil
gauge - it should be above the red mark on the
sight glass. If necessary, add compressor oil.
Prevent oil leaks from the joints and on the
external surfaces of the compressor.
6.
Install the air filter.
7.
Check mains voltage.
8.
Securely connect the compressor to the
compressed air consumers using an appropri-
ate pneumatic tool.
9.
Open the condensate drain valve and
then close it.
10.
Starting and stopping of the compressor
is carried out only by a switch on the pressure
relay unit. The pressure relay automatically
turns the compressor on and off, maintaining
the pressure of compressed air within the
specified limits.
Attention! In order to avoid overheating of the
electric motor, the compressor operates in a
two-stroke mode with periodic switching on/off.
In case of overheating, the thermal
protection installed on the motor is triggered.
Содержание PAC24-C
Страница 1: ...RU PAC24 C PAC50 C AIR COMPRESSOR EN PROGRESSIVE INNOVATIONAL TECHNOLOGY...
Страница 11: ...12 Air compressor P I T WARRANTY CARD...
Страница 12: ...1 2 3 4 5 6 5 7 8 9 10 11 12 13 14 15 0 35 16 1 2 3 4 5 6 7 8 9 10 11 12...
Страница 13: ...13...
Страница 14: ...14...
Страница 15: ...1 2 3 5 6 7 8 9 10 11 15 4...
Страница 16: ...16...
Страница 17: ...17 1 2 1 2 1 1 1 2 3 1 2 3 1 1 1 1...
Страница 18: ...18 100 1 2 100 300...
Страница 19: ...19 1 2 12 P I T 3 4 5 5...
Страница 22: ...P I T 22...
Страница 23: ...12 P I T...
Страница 24: ...13 Schema PAC24 C Air compressor...
Страница 25: ...14 Schema PAC50 C Air compressor...