background image

lower temperatures than conventional corona discharge generators thus improving reliability and 
efficiency without the need for separate cooling water circuitry; 4) Maximum ozone output with 
minimum high voltage input. 

 

 

Each cell(s) is separately housed within its own stainless holding chamber (manifold) with consideration 
for maximum efficiency.  In other words, all the air that is drawn through the chambers is passed 
directly through the ozone producing region (corona gap) with little or no waste from improper 
channeling. 

 

 

Each manifold is neatly constructed and conveniently clip into a fuse holder like device for ease in 
assembly and servicing. MTTR (Mean Time To Replace) a manifold in less than 3 minutes. Due to the 
lost cost of a replacement cell/manifold, the existing cell is not serviceable and is to be considered a 
throw-away item should it fail. 

 

5.0 Operating Conditions

 

 

 

Your generator requires special operating conditions in order to maintain performance and reliability. 
Your ozone generator is designed to be operated under a negative or positive pressure situation.  Your 
Ozotech ozone generator has been factory tested to operate at a maximum positive pressure of 

5 psi

Warranty coverage of your equipment is contingent upon strict compliance with the operating 
conditions specified in this manual. 

 

 

5.1  Operating Environment

 

 

External 

It is most important to choose a cool, clean external operating environment.   Consideration of these 
factors should be a priority.  Mount your ozone generator in the best possible operating environment 
that is available at chosen site.  If at all possible, mount in an area that is free of airborne moisture 
particles. 

 

Internal 

Keep the inside of the generator chassis clean and dry.  Dust particles and condensation pose a 
challenge to the consistent operation of all ozone generators.  Make a note to inspect the internal 
cleanliness of the equipment when you perform your scheduled maintenance.  For further information 
refer to section 6.0. 

 

 

5.2  Input Power Requirements

 

 

 

Ozotech, Inc., offers the Poseidon ozone generator in a variety of configurations to accommodate a 

 

 

 

M43-31281 BK1.5 REV A1 

Содержание Poseidon Series

Страница 1: ...Owner s Manual Poseidon Series Ozone Generators Designed and Manufactured Exclusively by Ozotech Inc ...

Страница 2: ...ating Environment 6 5 2 Input Power Requirements 6 6 0 Maintenance 7 6 1 Ozone Generator Maintenance 7 6 2 Corona Discharge Cell Servicing 8 7 0 Spare Replacement Parts 8 8 0 Fusing 8 9 0 Troubleshooting Guide 9 10 0 Component Replacement 10 10 1 Corona Discharge Cell Replacement 10 10 2 Illustration 1 0 10 M43 31281 BK1 5 REV A1 2 To access digital copy of manual online scan the QR code below ...

Страница 3: ...shall be null void and non binding upon Ozotech Incorporated if Ozotech Incorporated or authorized service center determines the cause of malfunction or defect to be a result of 1 Failure to perform proper maintenance as defined and recommended in this manual 2 Failure to adhere to and provide proper operating conditions as defined in this manual including operation outside of temperature range op...

Страница 4: ... if possible Clearly write the RMA number on the outside of the shipping package Verify that the address is correct and current Shipments that are not factory authorized will be refused It is recommended that you ship with a reputable and reliable shipping company and that the contents of the package are insured Ozotech Inc accepts no responsibility for damage or loss of equipment in transit ALL F...

Страница 5: ...ction of high voltage low current electrical arcs across an air space When oxygen O2 is passed through the air space some molecules are split resulting in free oxygen atoms which quickly attach themselves to intact O2 molecules The result is a very unstable form of oxygen O3 ozone It is the extra atom of oxygen that gives ozone its superior oxidation capabilities 4 1 Pulse Modulated Corona Dischar...

Страница 6: ... and reliability Your ozone generator is designed to be operated under a negative or positive pressure situation Your Ozotech ozone generator has been factory tested to operate at a maximum positive pressure of 5 psi Warranty coverage of your equipment is contingent upon strict compliance with the operating conditions specified in this manual 5 1 Operating Environment External It is most important...

Страница 7: ... maximum efficiency and long life Simple maintenance and appropriate operating conditions are the only requirements to keep the unit functioning within manufacturer s specifications Performing any other modifications or adjustments to internal components will cause the unit to function outside of manufacturer s specifications and will cause damage to the unit not covered under terms of warranty 6 ...

Страница 8: ... of a replacement cell is minimal Refer to the diagrams at the back of this manual for the typical unit layout 7 0 Spare Replacement Parts Denotes recommended spare maintenance parts with initial purchase Followed by quantity per unit recommended for one year s scheduled maintenance Part Description 33217 P Corona Discharge Cell 40126 Frequency Driver Board 47018 303 Viton Check Valve 40080 03 Wal...

Страница 9: ...correct f u s e value and type are being used Replace with appropriate size type fuse Refer to Spare Replacement Parts for replacement part information Unit is connected to improper power source Refer to label on side of chassis for correct voltage requirements Unit i s putting out approximately of rated output Improper power source Refer to label on the side of the unit to ensure that unit is plu...

Страница 10: ...ations below Disconnect unit from power source Remove four press in rivets that secure cover and remove cover Pull the CD cell out of the fuse clips then disconnect hoses and Hi Voltage wire that is connected to the male spade lug on the printed circuit Reverse steps 1 thru 3 to install replacement CD cell 10 2 Illustrations ...

Отзывы: