4.0 Specifications
Input Power Requirements:
• Operating Voltage (specified): 11.7 VDC to 13.9 VDC
• Power consumption: 700mA to 1.3A @ 12VDC (8.4 to 15.6 watts) nominal
Fusing Specification: 800 mA fast blow, IEC 127, 5x20mm
Product Size (L x W x H): 9” x 6” x 5”
Shipping Weight: 5 lbs.
Ozone Output: 220-440 mg/hr.
Enclosure: Powder coated aluminum
5.0 Component Replacement
Electrical failure is usually the result of a mechanical failure. For example, should the CD cell
become plugged with nitric byproducts or should water back into the cell, it could cause a
catastrophic electrical failure. Proper air preparation can usually avoid the build-up of nitric
byproducts.
5.1 CD Cell Replacement
Should a CD cell need to be replaced, refer to the following procedure and figure 3, in section 7.0.
CAUTION: Disconnect ozone generator from power supply before performing
service.
1.
Remove the 4 screws that secure cover and remove cover.
2.
Cut the shipping cable tie around the CD cell. Pull the CD cell out of the retaining clips,
then disconnect tubing and the high voltage wire connection.
3.
Reverse steps 1 & 2, reconnect power to the ozone generator, and return to service.
4