1.3 Operation
Ozotech, Inc., offers the AIM PCS 400 ozone generator with a variety of electrical input
configurations to accommodate a wide range of applications. Configurations include a standard
AC to DC wall transformer (included with purchase), a cigarette lighter adapter or twisted wire for
connection to a hard 12 VDC source such as a car, boat or RV battery circuit. Most supply voltages
fluctuate, so it is necessary to monitor your voltage and assure it is within acceptable variance
values listed in section 4.0.
Your ozone generator is designed for simple and easy use.
1.
Connect your air preparation device to the air input tubing of the ozone generator.
2.
Connect your ozone output tubing, with inline check valve, to your appropriate ozone
injection device.
3.
Connect power to the DC power input jack (green LED will illuminate). Turn on your ozone
generator using the High/Low rocker switch (corresponding red LED’s will illuminate).
a.
The ‘Low’ setting will produce 220 mg/hr. gaseous ozone, while the ‘High’ setting will
produce 440 mg/hr. of gaseous ozone.
4.
Adjust and balance air flow using Ozotech’s ‘Venturi Calibration Guide’, available for
download at www.ozotech.com/support.
2.0 Maintenance
The AIM series generators are delivered factory tested, calibrated, and adjusted for maximum
efficiency and long life. Simple maintenance and appropriate operating conditions are the only
requirements to keep the unit functioning within manufacturer’s specifications.
Performing any modifications or adjustments to internal components will cause the unit to
function outside of manufacturer’s specifications and will cause damage to the unit not covered
under terms of warranty.
2.1 Ozone Generator Maintenance
Frequency of Maintenance: Every 4800 hours or 6 months of operation:
CAUTION: Disconnect ozone generator from power supply before performing
maintenance.
1.
Remove the screws that secure cover and remove cover.
2.
Clean or replace the Corona Discharge (CD) cells.
a. A CD cell cleaning kit may be purchased from Ozotech, Inc. Reference section 3.0 for
more information.
b. Refer to section 5.1 for CD cell replacement.
3.
Clean interior and exterior of chassis.
4.
Replace ozone resistant check valves on the air in or ozone gas outlet lines.