![Ozotech AIM PCS 200 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/ozotech/aim-pcs-200/aim-pcs-200_installation-and-service-manual_1667160008.webp)
4.0 Specifications
Input Power Requirements:
• Operating Voltage (specified): 11.7 VDC to 13.9 VDC
• Power consumption: 600mA @ 12VDC (7.2 watts) nominal
Product Size (L x W x H): 7” x 4.5” x 2”
Shipping Weight: 2 lbs.
Ozone Output: 220 mg/hr.
Enclosure: Aluminum
5.0 Component Replacement
Electrical failure is usually the result of a mechanical failure. For example, should the CD cell
become plugged with nitric byproducts or should water back into the cell, it could cause a
catastrophic electrical failure. Proper air preparation can usually avoid the build-up of nitric
byproducts.
5.1 CD Cell Replacement
Should a CD cell need to be replaced, refer to the following procedure and figure 3, in section 7.0.
CAUTION: Disconnect ozone generator from power supply before performing
service.
1.
Remove the 4 screws that secure cover and remove cover.
2.
Pull the CD cell out of the retaining clips, then disconnect tubing and the high voltage wire
connection.
3.
Reverse steps 1 & 2, reconnect power to the ozone generator, and return to service.