1.0 Installation and Operation
Your ozone generator requires special operating conditions in order to maintain performance
and reliability. Your ozone generator is designed to be operated under a negative or positive
pressure situation. Your ozone generator has been factory tested to operate at a maximum
positive pressure of 5 psi.
The use of an air preparation device is essential to increase your ozone generator performance
and service life. Ozotech Inc. provides several air preparation options, based on application.
Contact your distributor, an Ozotech, Inc. sales representative, or visit www.ozotech.com for more
information
Warranty coverage of your equipment is contingent upon strict compliance with the operating
conditions specified in this manual.
1.1 Operating Environment
External
It is most important to choose a cool, clean external operating environment. Consideration of
these factors should be a priority. Mount your ozone generator in the best possible operating
environment that is available at the chosen site. If possible, mount in an area that is free of
airborne moisture particles.
Internal
Keep the inside of the generator chassis clean and dry. Dust particles and condensation pose a
challenge to the consistent operation of all ozone generators. Make a note to inspect the internal
cleanliness of the equipment when you perform scheduled maintenance. For further information
refer to section 2.0.
1.2 Installation
The AIM PCS 200 is designed to be mounted vertically or horizontally on a wall, panel, or
framework. There are three (3) keyhole mounting features within the chassis, sized for #8 screws.
The use of wall anchors is recommended when stud(s) are not available. A minimum of six (6)
inches clearance is required around the top, bottom and sides of the unit to ensure access and
proper air flow. Choose a mounting location that permits power connection without the use of
extension cords.
1